Trane PKG-SVX17A-EN manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Trane PKG-SVX17A-EN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Trane PKG-SVX17A-EN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Trane PKG-SVX17A-EN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Trane PKG-SVX17A-EN should contain:
- informations concerning technical data of Trane PKG-SVX17A-EN
- name of the manufacturer and a year of construction of the Trane PKG-SVX17A-EN item
- rules of operation, control and maintenance of the Trane PKG-SVX17A-EN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Trane PKG-SVX17A-EN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Trane PKG-SVX17A-EN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Trane service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Trane PKG-SVX17A-EN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Trane PKG-SVX17A-EN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PKG-S VX1 7A -EN Sept ember 20 07 Models “ A ” and later Design S equence Installation Owner Diagnostics Split S yst em Cooling Condensers Model CT A 7 1/2 t o 15 T ons CT A 090A***A – 60 HZ 120A***A – 60 HZ 120B***A – 60 HZ 180B***A – 60 HZ[...]

  • Page 2

    © 2007 American Standard All rights reser ved PKG-SVX17A-EN Notice Overvie w of Manual Note: One copy of this document ships inside eac h un it and is customer property . It must be retained by the unit’ s maintenance personnel. This booklet descri bes proper installa- tion, operatio n, and maintenance pr o- cedures for air cooled systems. By ca[...]

  • Page 3

    PKG-SVX17A-EN 3 Contents Installation/Star tup/Commissioning 4 Model Number Description 4 Unit Dimensions 5 Electrical Data 8 Unit Inspection 9 Initial Leak T est 9 Lif ting Recommendations 9 Clearances 10 Unit Mounting 10 R efrigerant Piping 10 Leak Chec k 12 S ystem Evacuation 12 R efrigeration Charging 12 Electrical Wiring 13 Low V oltage Wiring[...]

  • Page 4

    4 PKG-SVX17A-EN Model Nu mber Descri ption All products are identified by a multi - ple-c hara cter model number that pre - cisely identifies a particular type of unit. An explanation of the alphanu - meric identification code is provided below. Its use will enable the owner/ operator , installing contractors, and service enginee rs to define the o[...]

  • Page 5

    PKG-SVX17A-EN 5 Figure 1 — CTA090A Figure 2 — CTA120A Unit Dimensions[...]

  • Page 6

    6 PKG-SVX17A-EN Figure 3 — CTA120B Unit Dimensions[...]

  • Page 7

    PKG-SVX17A-EN 7 Figure 4 — CTA180B Unit Dimensions[...]

  • Page 8

    Basic Unit Characteristics Outdoor Fan Motor Model Number Electri cal Characteristics Allowable V oltage Rang e Minimum Circuit Ampacity Maximum Fus e Size Qty . HP Amps FLA Amps LRA CT A090A1 208-230/60/1 187 -254 15 15 1 1/2 3.1 8.1 CT A090A2 460/60/1 414-506 15 15 1 1/2 1. 6 3.7 CT A090A8 575/60/1 518-632 15 15 1 1/2 1. 2 3.0 CT A120A1 208-230/6[...]

  • Page 9

    PKG-SVX17A-EN 9 Installation proced ures should be per - formed in the sequence that they appear in this manual. Do no t destroy or remo ve the manual from the unit. The manual sh ould remain weather - protected with the un it until all inst al - lation proced ures are complete. Note: It is not the intention of this manual to cover all possible var[...]

  • Page 10

    10 PKG-SVX17A-EN Clearances Pro vide enough spac e around the unit to allow unrestricted access to all ser - vice points. Refer to Figure 1 through Figure 4 for unit d imensions and mini - mum required service and free air clearances. Observe the following points to insure proper uni t operation. A. Do not install the unit under a low overhang. Con[...]

  • Page 11

    PKG-SVX17A-EN 11 Note: Insulate all refrigerant piping and connections. Refrigerant Piping Pr ocedures (Outdoor Units) Eac h CT A unit ships with a holdin g c h arge of dry nitrogen. Th e nitrogen should be remo ved and the entire sys - tem evacuated (at th e proper time) to avoid possib le contamination. 1 . Remo ve the service access panel. 2. Lo[...]

  • Page 12

    12 PKG-SVX17A-EN WARNING: Hazardous Pressures! Coil has a nitr ogen holding c harge. Do not remov e seal caps by heating the caps while coil is under pressure. Depress the gauge port valv e cores to gradu - ally relie ve nitrogen holding c harge. Remov e val ve core s before remo ving the tubing seal caps. Failure to pr operly reliev e pressure cou[...]

  • Page 13

    PKG-SVX17A-EN 13 T able 3: CT A R efrigerant Charge Model Refrigerant Charge (R-41 0A)* CT A090A w/SCRH030 18.1 lbs CT A090A w/SCRH050 1 9.9 lbs CT A120A w/SCRH075 20.8 lbs CT A120B w/SCRH1 0 0 1 1 .9 lbs (Ckt. #1 & #2) CT A180B w/SCRH120 16.8 lbs. (Ckt. #1) 16.0 lbs. (Ckt. #2) CT A180B w/SCRH150 17 .5 lbs. (Ckt. #1) 16.9 lbs. (Ckt. #2) * Suffi[...]

  • Page 14

    14 PKG-SVX17A-EN Note: 1 . Wiring shown with dashed lines is to be furnished and installed by the cus - tomer . All customer supplied wiring must be copper only and must con - form to NEC and local electrical codes. Codes may require line o f sight be - tween disconnect switch and unit. CT A090A/S(C,I)RH030 CT A090A/S(C,I)RH050 CT A1 20A/S(C,I)RH07[...]

  • Page 15

    PKG-SVX17A-EN 15 Field Wiring[...]

  • Page 16

    16 PKG-SVX17A-EN Wiring[...]

  • Page 17

    PKG-SVX17A-EN 17 Wiring[...]

  • Page 18

    18 PKG-SVX17A-EN Wiring[...]

  • Page 19

    PKG-SVX17A-EN 19 Wiring[...]

  • Page 20

    20 PKG-SVX17A-EN Refrigeration Diagram Figure 1 1: T ypical Split Sy stem Cooling Diagram[...]

  • Page 21

    PKG-SVX17A-EN 21 Installation Chec klist Complete this c hec klist once the unit is installed to verif y that all recom - mended procedures have been accomplished before starting the sys - tem. Do not operat e the system until all items covered by this c hec klist are complete. [ ] Inspect unit lo cation for proper required service clearances. [ ] [...]

  • Page 22

    22 PKG-SVX17A-EN Unit Start-Up Once the unit is properly installed and pre-star t procedures are complete, start th e unit by turn ing the System Switc h on the indoor ther - mostat to either HEA T , COOL or AUT O. The system sh ould operate normally . Seq u ence of Operation General Operation of the sy stem cooling (and optional heati ng) cycles i[...]

  • Page 23

    PKG-SVX17A-EN 23 W ARNING: Hazardous Service Pr ocedures! The maintenance and trou ble - shooting procedures recom mend - ed in this section of the manual could result in exposure to electri - cal, mec hanical or other potential safety hazards. Alw ays re fer to the safety warnings pr ovided throughout this manual concern - ing these pr ocedures. W[...]

  • Page 24

    Date Ambient Te m p . F Evaporator Entering Air Compressor Superheat Subcooling Dry Bul b We t B u l b Suction Pre ssu re Disc harge Pre ssu re Circuit #1 (F) Circuit #1 (F) 24 PKG-SVX17A-EN Maintenance Log Note: Perform each inspection on ce per month (during cooling seaso n) while unit is operating. Maintenance[...]

  • Page 25

    PKG-SVX17A-EN 25 Warranty Inf ormation Standard Warranty The standard split syst em cooling co ndenser war ranty is T rane’ s parts- only w arranty , running 1 2-months from start up, not to exceed 18- months from shipme nt. Extended Warranty The o ptional extended war ranty is a second through fifth y ear war ranty . The time star ts at the end [...]

  • Page 26

    [...]

  • Page 27

    [...]

  • Page 28

    T rane has a policy of continuous product and pro duct data improvement and reserves the right to c hange design and specific ations without notice. Literature Order Number PKG-SVX17A-EN Date September 2007 Supersedes SS-SVN1 1A-EN October 20 04 T rane A business of American Standar d Companies www .trane.com For more information, contact your loca[...]