A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Trane UX1D120A9H51B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Trane UX1D120A9H51B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Trane UX1D120A9H51B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Trane UX1D120A9H51B should contain:
- informations concerning technical data of Trane UX1D120A9H51B
- name of the manufacturer and a year of construction of the Trane UX1D120A9H51B item
- rules of operation, control and maintenance of the Trane UX1D120A9H51B item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Trane UX1D120A9H51B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Trane UX1D120A9H51B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Trane service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Trane UX1D120A9H51B.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Trane UX1D120A9H51B item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    *UX1B040A9H21B *UX1B060A9H31B *UX1B080A9H31B *UX1C100A9H41B *UX1D120A9H51B High Efficiency Single Stage Upflow/ Horizontal and Downflow/ Horizontal Gas-Fired, Direct Vent Condensing Furnaces ALL phases of this installation must comply with NA TIONAL, ST A TE AND LOCAL CODES IMPORT ANT — This Document is customer property and is to remain with thi[...]

  • Page 2

    © 2008 Trane All Rights Reserved 18-CD22D1-8 Installer’ s Guide SAFETY SECTION The following safety practices and precautions must be followed during the installation, servicing, and operation of this furnace. 1. Use only with the type of gas approved for this fur- nace. Refer to the furnace rating plate. 2. Install this furnace only in a locati[...]

  • Page 3

    18-CD22D1-8 3 Installer’ s Guide INST ALLA TION INSTRUCTIONS General Installation Instructions 3 Location and Clearances 4 Outline Drawings 5 Upflow Installation 7 Downflow Installation 7 Horizontal Installation 7 Air For Combustion and Ventilation 8 Duct Connections 1 0 Return Air Filters 1 1 General Venting Instructions 1 4 Venting Material 1 5[...]

  • Page 4

    4 18-CD22D1-8 Installer’ s Guide LOCA TION AND CLEARANCES The location of the furnace is normally selected by the ar- chitect, the builder, or the installer. However, before the fur- nace is moved into place, be sure to consider the following requirements: 1. Is the location selected as near the vent and as cen- tralized for heat distribution as [...]

  • Page 5

    18-CD22D1-8 5 Installer’ s Guide From Dwg. 21C341884 Rev. 1 *UX1-H OUT LINE DRA WING (ALL DIMENSIONS ARE IN INCHES)[...]

  • Page 6

    6 18-CD22D1-8 Installer’ s Guide From Dwg. 21C341885 Rev. 0 *DX1-H DOWNFLOW/ HORIZONT AL OUT LINE DRA WING (ALL DIMENSIONS ARE IN INCHES)[...]

  • Page 7

    18-CD22D1-8 7 Installer’ s Guide UPFLOW INST ALLA TION Standoffs and screws (See Figure 1) are included with the cased coils for attachment to the furnace. There are clearance alignment holes near the bottom of the coil wrapper. Drill screws are used to engage the furnace top flanges. The standoff is inserted into the cabinet alignment hole. The [...]

  • Page 8

    8 18-CD22D1-8 Installer’ s Guide The furnace must also be elevated a minimum of 6 inches to allow clearance for the condensate drain to exit the cabinet in the horizontal position. The horizontal furnace may also be suspended from the joists using 3/8" all-thread rods with pieces of angle iron underneath the furnace to form a hanging rack at[...]

  • Page 9

    18-CD22D1-8 9 Installer’ s Guide 6 MINIMUM AREA IN SQU ARE FEET FOR UNCONFINED SP ACE INST ALLA TIONS FURNA CE MAXIMUM BTUH INPUT RA TING WITH 8 FT . CE ILING MINIMUM AREA IN SQU ARE FEET OF UNCONFINED SP ACE 60,000 80,000 100,000 120,000 375 500 625 875 1. All air from inside the building as in Figure 8: The confined space shall be provided with[...]

  • Page 10

    10 18-CD22D1-8 Installer’ s Guide DUCT CONNECTIONS Air duct systems should be installed in accordance with standards for air conditioning systems, National Fire Protection Association Pamphlet No. 90. They should be sized in accordance with ACCA Manual D or which- ever is applicable. Central furnaces, when used in connection with cooling units, s[...]

  • Page 11

    18-CD22D1-8 11 Installer’ s Guide 9. The horizontal installation of the upflow furnace requires an external filter section. Do NOT use the bottom return filter within the furnace. Filter kits are available for horizon- tal applications. 10. Connect duct work to furnace. See Outline Drawing for supply and return duct size and location. Flex- ible [...]

  • Page 12

    12 18-CD22D1-8 Installer’ s Guide e RETURN AIR FILTERS FOR UPFLOW FURNACE IN HORIZONT AL CONFIGURA TION When the Upflow Furnace is installed in the horizontal configuration, the return air filters must be installed exterior to the furnace cabinet. Remote filter grilles may be used for homeowner convenience or the filters may be installed in the d[...]

  • Page 13

    18-CD22D1-8 13 Installer’ s Guide T ABLE 6 MINIMUM CLEARANCE FROM COMBUSTIBLE MA TERI ALS FOR UPFLO W/HORIZONT AL AND DOWNFLO W/ HORIZONT AL FURNA CES UNIT LOCA TION FURNA CE SURF ACE VER TICAL CLOSET HORIZONT AL CLOSET HORIZONT AL ALCO VE / A TTI C SIDES 0" 1" 0" BA CK 0" 3" 6" TO P 1 " 1 " 1 " FRONT [...]

  • Page 14

    14 18-CD22D1-8 Installer’ s Guide 3. Insofar as is practical, close all building doors and windows and all doors between the space in which the appliances remaining connected to the common venting system are located and other spaces of the building. Turn on clothes dryers and any appliances not connected to the common venting system. Turn on any [...]

  • Page 15

    18-CD22D1-8 15 Installer’ s Guide NO TE: It is recommended that the first joints from the furnace be connected and sealed with high temperature RTV. This will enable the pipes to be removed later without cutting. Be sure to properly support these joints. BONDING OF PVC Commercially available solvent cement must be used to join the pipe and fittin[...]

  • Page 16

    16 18-CD22D1-8 Installer’ s Guide HORIZONT AL INST ALLA TION (Upflow/ Horizontal or Downflow/ Horizontal) NO TE: In horizontal venting when the factory supplied “off- set” (2X3 reducing coupling) is used for 3” vent pipe installation, make sure the marking “Top” is located on the top side of the pipe. The straight side must be on bottom[...]

  • Page 17

    18-CD22D1-8 17 Installer’ s Guide MAXIMUM VENT LENGTH: MODEL DIRECT VENT (2 PIPE SYSTEM) - MAXIMUM T O T AL EQUIV ALENT FEET FO R VENT AND INLET AIR PIPES (See Notes) NONDIRECT VENT (1 PIPE SYSTEM) - MAXIMUM T OT AL EQUIV ALENT FEET FOR VENT PIPE ONL Y (See Notes) 2" PIPE & FITTIN GS 2-1/2" PIPE & FITTINGS 3" PIPE & FIT[...]

  • Page 18

    18 18-CD22D1-8 Installer’ s Guide Direct V ent T erminal Clearances Canadian Installations US Installations A= Clearance abov e grade, v eranda, porch, deck , or balcony 12 inches (30 cm) 12 inches (30 cm) B= Clearance to window or door that may be opened 6 inches (15 cm) f or appliances =/< 10,000 Btuh ( 3 kw), 12 inches (30 cm) fo r applianc[...]

  • Page 19

    18-CD22D1-8 19 Installer’ s Guide Non-Direct V e nt T erminal Clearances Canadian Installations US Installations A= Clearance above gr ade, veranda, porch, deck, or balcon y 12 inches (30 cm) 12 inches (30 cm) B= Clearance to window or door that may be opened 6 inches (15 cm) for appliances =/< 10,000 Btuh (3 kw), 12 inches (30 cm) for applian[...]

  • Page 20

    20 18-CD22D1-8 Installer’ s Guide ▲ CAUTION ! When the vent pipe is exposed to temperatures below freezing, i.e., when it passes through unheated spaces, etc., the pipe must be insulated with 1/2 inch (22.7 mm) thick Armaflex-type insulation or equal. If the space is heated sufficiently to prevent freezing, then the insula- tion would not be re[...]

  • Page 21

    18-CD22D1-8 21 Installer’ s Guide ; SUPPORT HORIZONT AL PIPE EVERY 3' 0" WITH THE FIRST SUPPORT AS CLOSE TO THE FURNACE AS POSSIBLE. INDUCED DRAFT BLOWER, HOUSING, AND FURNACE MUST NOT SUPPORT THE WEIGHT OF THE FLUE PIPE. NOT E: VENT AND INLET MUST BE SUPPORTED A T A MAXIMUM OF 3' INTERV ALS 4 0" UPFLOW OR DOWNFLOW MODELS SEE [...]

  • Page 22

    22 18-CD22D1-8 Installer’ s Guide VENTING ROUTED THROUGH A MASONRY CHIMNEY VENT FITTING MA TERIAL – ST AINLESS STEEL Gas and liquid tight single wall metal vent fitting, de- signed for resistance to corrosive flue condensate such as Type 29-4C MUST be used throughout. These fittings and fitting accessories are to be supplied locally. DIRECTION [...]

  • Page 23

    18-CD22D1-8 23 Installer’ s Guide I MPORT ANT: The Commonwealth of Massachusetts requires compliance with regulation 248 CMR 4.00 and 5.00 for installation of through – the – wall vented gas appliances as follows: For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in [...]

  • Page 24

    24 18-CD22D1-8 Installer’ s Guide n SUPPORT THE SINGLE WA L STAINLESS STEEL GAS VENTING AND CENTER IT I N THE CHIMNEY OPENING WI T ANGLES AS SHOWN OR ANOTHER EQUIVALENT MANNER. NOTE: HORIZONTAL VENTING TO VERTICAL VENTING 6 IN. MIN. E E CAUTION STAINLESS STEEL VENT CAP TYPE 29-4C ST AINLESS STEEL VENTING - USED THROUGH CHIMNEY THA T VENTS ANOTHER[...]

  • Page 25

    18-CD22D1-8 25 Installer’ s Guide CONDENSA TE DRAIN INSTRUCTIONS ▲ ▲ CAUTION ! IT IS RECOMMENDED THA T A DRAIN P AN BE INST ALLED UNDER THE FURNACE T O PREVENT PROPER TY D AMA GE, PERSONAL INJUR Y OR DEA TH FROM LEAKING CONDEN- SA TE. VERTICAL A PPLICA TIONS Upflow furnace - The connection tubing for left and right side drainage is shipped in[...]

  • Page 26

    26 18-CD22D1-8 Installer’ s Guide The trap must be repositioned to the exterior of the cabinet. Remove the trap from its present location and reposition the trap outside of the unit, through the long circular hole, next to the secondary recuperative cell. Remove the larger drain line (from the secondary cell) and trim to fit between the secondary[...]

  • Page 27

    18-CD22D1-8 27 Installer’ s Guide ELECTRICAL CONNECTIONS Make wiring connections to the unit as indicated on en- closed wiring diagram. As with all gas appliances using electrical power, this furnace shall be connected into a permanently live electric circuit. It is recommended that furnace be provided with a separate “circuit protec- tion devi[...]

  • Page 28

    28 18-CD22D1-8 Installer’ s Guide OUTDOOR UNIT (NO TRANSFORMER) SEE NOTE 6 F rom drawing B340388 Rv 2 SEE NOTE 8 FURNACE B/C B/C TO 115 V 1 PH., 60 HZ., POWER SUPPL Y PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 FIELD WIRING DIA GRAM FOR 1 ST AGE FURNA CE 1 ST AGE HEA TING, 1 ST A GE COOLING USING A 1 ST AGE HEA TING, 1 ST A GE COOLING THERMOST [...]

  • Page 29

    18-CD22D1-8 29 Installer’ s Guide TWIN TWIN R1 R1 TWINNING CONNECTION DIAGRAM FOR TWINNING 1 ST AGE FURNA CES WITH SINGLE WIRE TWINNING FEA TURE 1 ST AGE HEA T / 1 ST AGE COOL THERMOST A T 1 ST AGE HEA TING / COOLING THERMOST A T FURNACE NO . 1 FURNACE NO . 2 BLOWER OPERA TION OF UNIT NO. 2 IS SYNCRONIZED WITH UNIT NO. 1 VIA SIGNALS FROM TWIN CON[...]

  • Page 30

    30 18-CD22D1-8 Installer’ s Guide UPFLOW – LEFT HAND GAS PIPING UPFLOW – RIGHT HAND GAS PIPING * AUTOMA TIC GAS V ALVE WITH MANUAL SHUTOFF MAIN MANUAL SHUTOFF V ALVE GROUND UNION JOINT DRIP LEG AUTOMA TIC GAS V ALVE WITH MANUAL SHUTOFF MAIN MANUAL SHUTOFF V ALVE GROUND UNION JOINT DRIP LEG THE DOWNFLOW (VERTICAL) MA Y BE INST ALLED LEFT OR RI[...]

  • Page 31

    18-CD22D1-8 31 Installer’ s Guide ▲ CAUTION ! Use a backup wrench on the gas valve when installing gas piping to prevent damage to the gas valve and manifold assembly. T ABLE 10 NA TURAL GAS ONL Y T ABLE OF CUBIC FEET PER HOUR OF G AS FOR V ARIOUS PIPE SIZES AND LENGTHS PIPE SIZE LENGTH OF PIPE 10 20 30 40 50 60 70 1/2 132 92 73 63 56 50 46 3/4[...]

  • Page 32

    32 18-CD22D1-8 Installer’ s Guide Input rate changes can be made by adjusting the mani- fold pressure (min 3.0 - max 3.7 in. W.C. - Natural Gas) or changing orifices (orifice change may not always be required). If the desired input rate can not be achieved with a change in manifold pressure, then the orifices must be changed. LP installations wil[...]

  • Page 33

    18-CD22D1-8 33 Installer’ s Guide ANSI Z223.1/ NFPA 54 or National Standard of Canada, Natural Gas and Propane Installation Code, CSA B149.1 . Installation of this furnace at altitudes above 2,000 ft. (610m) shall be made in accordance with the listed high Altitude Conversion Kit available with this furnace. IMPORT ANT: Re-install the propane ori[...]

  • Page 34

    34 18-CD22D1-8 Installer’ s Guide LIGHTING INSTRUCTIONS ▲ WARNING ! DO NO T attempt to manually light the burner. Failure to follow this warning could result in property damage, personal injury or death. Lighting instructions appear on each unit. Each instal- lation must be checked out at the time of initial start up to insure proper operation [...]

  • Page 35

    18-CD22D1-8 35 Installer’ s Guide AIRFLOW ADJUSTMENT Check inlet and outlet air temperatures to make sure they are within the ranges specified on the furnace rat- ing nameplate. If the airflow needs to be increased or decreased, see the wiring diagram for information on changing the speed of the blower motor. ▲ WARNING ! Disconnect power to the[...]

  • Page 36

    36 18-CD22D1-8 Installer’ s Guide 8. RESET A FTER BURNER BOX LIMIT SHUTDOWN If the furnace shuts down, one thing that can be checked is the burner box temperature limit switch. It is located on the bottom of the burner box. The vent and combustion air inlet terminations should be checked for blockage. If blockage exists, clear the problem and the[...]

  • Page 37

    18-CD22D1-8 37 Installer’ s Guide INTEGRATED FURNACE CONTR OL ERR OR FLASH CODES Flashing Slow --- Nor mal - No call f or Heat Flashing F ast --- Nor mal - Call f or Heat Continuous ON --- Replace IFC Continuous OFF --- Check P ow er 2 Flashes --- System Lock out (Retries or Recycles exceeded) 3 Flashes --- Draft Pressure Error - P ossible prob l[...]

  • Page 38

    Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice. Trane 6200 Troup Highway Tyler, TX 75707 For more information contact your local dealer (distributor) Literature Order Number 18-CD22D1-8 File Number 18-CD22D1-8 Supersedes 18-CD22D1-7 Dat[...]