Go to page of
Similar user manuals
-
Air Conditioner
Trane TRG-TRC013-EN
77 pages 2.35 mb -
Air Conditioner
Trane RAUC-C60
112 pages 4.53 mb -
Air Conditioner
Trane GAF2A0A36S31SA
20 pages 1.97 mb -
Air Conditioner
Trane XL
6 pages 0.36 mb -
Air Conditioner
Trane PKG-PRC007-EN
52 pages 0.88 mb -
Air Conditioner
Trane RAUC-C40
112 pages 4.53 mb -
Air Conditioner
Trane TSD
68 pages 2.34 mb -
Air Conditioner
Trane FTXS18DVJU
30 pages 1.73 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Trane XR15, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Trane XR15 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Trane XR15. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Trane XR15 should contain:
- informations concerning technical data of Trane XR15
- name of the manufacturer and a year of construction of the Trane XR15 item
- rules of operation, control and maintenance of the Trane XR15 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Trane XR15 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Trane XR15, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Trane service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Trane XR15.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Trane XR15 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
XR15 4TTR5 1 1 / 2 - 5 T ons (018E - 061E) Split System Cooling Pr oduct Data PUB. NO . 22-1831-06[...]
-
Page 2
© 2009 T rane 2 22-1831-06 Featur es and Benefits • CLIMA TUFF ® compressor •Efciencyupto 17.0 SEER •Allaluminum SPINE FIN ™coil • WEA THERGU ARD ™f asteners • QUICK-SESS ™cabinet, ser viceaccessandrefrigerant connectionswithfullcoil protection •?[...]
-
Page 3
22-1831-06 3 Contents Features and Benefits 2 General Data 4 ProductSpecications 4 A-weightedSoundP o werLe vel[dB(A)] 4 Accessor yDescriptionandUsage 6 AHRIStandardCapacityRatingConditions 6 Model Nomenc lature 7 Electrical Data 8 Dimensions 15 Mechanical Specification Options 16[...]
-
Page 4
4 22-1831-06 Product Specifications Model No. 1 4TTR5018E1 4TTR5024E1 4TTR5030E1 4TTR5036E1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 9 9 12 19 Max Fuse Size (Amps) 15 15 20 30 Compressors CLIMA TUFF ® CLIMA TUFF ® CLIMA TUFF ® CLIMA TUFF ® - SCROLL No . Used - No. Stages 1-1 1-1 1-1 [...]
-
Page 5
22-1831-06 5 Product Specifications Model No. 1 4TTR5042E1 4TTR5048E1 4TTR5049E1 4TTR5060E1 4TTR5061E Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 230/1/60 Min Cir Ampacity 23 26 28 34 39 Max Fuse Size (Amps) 40 45 45 60 60 Compressors CLIMA TUFF ® - SCROLL CLIMA TUFF ® - SCROLL CLIMA TUFF ® - SCROLL CLIMA TU[...]
-
Page 6
6 22-1831-06 General Data AHRI Standard Capacity Rating Conditions AHRI ST AND ARD 210/240 RA TING CONDITIONS — (A) Cooling80°FDB,67°F WBairenteringindoorcoil, 95°FDBairenteringoutdoorcoil. AHRI ST AND ARD 270 RA TING CONDITIONS —(Noise ratingnumbersaredeterminedwiththeunit[...]
-
Page 7
22-1831-06 7 Model Nomenclatur e Refrigerant T ype 2 = R-22 4 = R-410A TRANE Product T ype W = Split Heat Pump T = Split Cooling Product Famil y Z = Leadership – Tw o Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial Family SEER 0 = 10 3 = 13 6 = 16 1 = 11 4 = 14 8 = 18 2 = 12 5 = 15 9 = 19 Split System Connections 1-6[...]
-
Page 8
8 22-1831-06 4TTR5018, 4TTR5024, 4TTR5030 Electrical Data Schematic Diagrams PrintedfromD154861P01Rev00[...]
-
Page 9
22-1831-06 9 4TTR5036 Electrical Data Schematic Diagrams PrintedfromD156022P03Rev00[...]
-
Page 10
10 22-1831-06 Electrical Data Schematic Diagrams PrintedfromD156058P03Rev00 4TTR5042[...]
-
Page 11
22-1831-06 11 Electrical Data Schematic Diagrams PrintedfromD156059P03Rev00 4TTR5048[...]
-
Page 12
12 22-1831-06 Electrical Data Schematic Diagrams PrintedfromD156677P01 4TTR5049[...]
-
Page 13
22-1831-06 13 Electrical Data Schematic Diagrams PrintedfromD156060P03Rev00 4TTR5060[...]
-
Page 14
14 22-1831-06 Electrical Data Schematic Diagrams PrintedfromD156678P02 4TTR5061E[...]
-
Page 15
22-1831-06 15 Dimensions F romDwg. D156010 MODELS BASE A B C D E F G H J K 4TTR5018E 3 730(28-3/4) 829(32-5/8) 756(29-3/4) 5/8 3/8 127(5) 76(3) 197(7-3/4) 57(2-1/4) 508(20) 4TTR5024E 3 730(28-3/4) 829(32-5/8) 756(29-3/4) 3/4 3/8 127(5) 76(3) 197(7-3/4) 57(2-1/4) 508(20) [...]
-
Page 16
T rane www .trane.com 10/10 T rane has a policy of continuous product and product data improv ement and it reserves the right to change design and specifications without notice. Mechanical Specification Options General The4TTR5isfullychargedfromthe f actor yforupto15f eetofpiping. This unitis[...]