A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Transition Networks SPOEB10XX-100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Transition Networks SPOEB10XX-100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Transition Networks SPOEB10XX-100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Transition Networks SPOEB10XX-100 should contain:
- informations concerning technical data of Transition Networks SPOEB10XX-100
- name of the manufacturer and a year of construction of the Transition Networks SPOEB10XX-100 item
- rules of operation, control and maintenance of the Transition Networks SPOEB10XX-100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Transition Networks SPOEB10XX-100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Transition Networks SPOEB10XX-100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Transition Networks service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Transition Networks SPOEB10XX-100.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Transition Networks SPOEB10XX-100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SPOEB10xx-100 User’ s Guide • Stand-Alone Media Converter • Power Over Ethernet • 10/100Base-TX to 100Base-FX The SPOEB10xx-1xx Power over Ethernet (POE) is a two port 10/100Base-TX to 100Base-FX media converter capable of providing power to Data Terminal Equipment (DTE) Power Devices (PD) via the Media Dependent Interface (MDI) twisted pai[...]

  • Page 2

    2 SPOEB10xx-1xx 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 SPOEB1029-100 RJ-45 100 m (328 ft.)* SC, 1310Tx/1550Rx nm single mode 20 km (12.4 miles) SPOEB1029-101 RJ-45 100 m (328 ft.)* SC, 1550Tx/1310Rx nm single mode 20 km (12.4 miles) Part Number Description WMBL Wall Mount Bracket Length: 4.0 in. (102 mm) , fit[...]

  • Page 3

    4 SPOEB10xx-1xx 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Installation -- continued Eight-position configur ation switc h -- continued 2 - Speed Up - Forces 100 Mb/s on the copper port. Down - Forces 10 Mb/s on the copper port. (Only when Auto-Negotiation is disabled) TP 10Mb/s Enabled TP 100Mb/s Enabled 2 3 - TP[...]

  • Page 4

    6 SPOEB10xx-1xx 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Installation- C ontinued Far-End Fault (always enabled) This troubleshooting feature generally used in conjunction with Link Pass Through to notify both end devices of a link loss. If the fiber RX signal is lost on the far end converter, the converter will[...]

  • Page 5

    8 SPOEB10xx-1xx 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Installation -- C ontinued P ow er ov er Ethernet (P oE) The SPOEB10xx-1xx media converter transmits electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet network. There are two modes of transmitting 48VDC PoE[...]

  • Page 6

    10 SPOEB10xx-1xx 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Cable Specifications The cable’s physical characteristics must meet or exceed IEEE 802.3™ specifications. Copper cable Category 5: (Minimum Requirement) Gauge 24 to 22 AWG Attenuation 22.0 dB /100m @ 100 MHz • Straight-through OR crossover twisted-p[...]

  • Page 7

    12 SPOEB10xx-1xx 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 T echnical Specifications For use with Transition Networks Model SPOEB10xx-100 or equivalent Standards IEEE 802.3, IEEE 802.3af Data Rate 10/100 Mb/s Packet Size (Max) 1522 bytes Mac Address 2K Dimensions 3.25" x 1” x 4.8" (82 mm x 25.4mm x 12[...]

  • Page 8

    14 SPOEB10xx-1xx 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 T roubleshooting -- continued 5. Is data being passed through the device? NO • Ensure the Powered Device (PD) IEEE 802.3af compliant. • Ensure the load to the Powered Device (PD) is less than 0.4 Amp. • Is a data source connected; if not, connect a [...]

  • Page 9

    16 Trademark Notice All registered trademarks and trademarks are the property of their respective owners. Copyright Restrictions © 2004 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical - without written permission from Transition Networks. Prin[...]