Go to page of
Similar user manuals
-
Computer Accessories
TRENDnet TRENDnet
11 pages 0.88 mb -
Computer Accessories
TRENDnet TV-IP212
11 pages 0.88 mb -
Computer Accessories
TRENDnet TK-210
13 pages 0.49 mb -
Computer Accessories
TRENDnet TPE-80WS
10 pages 0.76 mb -
Computer Accessories
TRENDnet High Spped USB 2.0 Data/TAM/Voice Modem
2 pages 0.23 mb -
Computer Accessories
TRENDnet TFM-56OU
2 pages 0.23 mb -
Computer Accessories
TRENDnet TV-IP212W
11 pages 0.88 mb -
Computer Accessories
TRENDnet TK-210K
13 pages 0.49 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of TRENDnet SMT1000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of TRENDnet SMT1000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of TRENDnet SMT1000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of TRENDnet SMT1000 should contain:
- informations concerning technical data of TRENDnet SMT1000
- name of the manufacturer and a year of construction of the TRENDnet SMT1000 item
- rules of operation, control and maintenance of the TRENDnet SMT1000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of TRENDnet SMT1000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of TRENDnet SMT1000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the TRENDnet service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of TRENDnet SMT1000.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the TRENDnet SMT1000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Oper at ion Ma nual Smart- UPS ™ Un inte rr upt i ble P o w er Sup p ly To w e r 750/1000/1 500/2200/3 000 V A 100/ 120 /23 0 V a c 500 V A 100 V a c[...]
-
Page 2
[...]
-
Page 3
1 Smar t- UPS 750/1 000/1500/ 220 0/3000 VA 100/120/ 230 Vac / 50 0 VA 100 Vac Tower Overv iew Produc t De scription The A PC ™ by Schneider Ele ctric Smart -UPS ™ i s a high per formance uninte rruptibl e power supply (UPS ). The UPS pr ovides p rotect ion fo r elect ronic equipment from utili ty powe r bla ckouts, brownouts , sa gs, an d sur [...]
-
Page 4
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 2 S pecifications For addi tional speci ficat ions, refer to the APC by Schnei der E lectric W eb si te a t www .apc.com. Envi ronment a l Te m p e r a t u r e Op erat ing 0° to 40° C (32° t o 104° F) St o r a g e -15° to 45° C (5° to 1 13° F) char ge UPS batt[...]
-
Page 5
3 Smar t- UPS 750/1 000/1500/ 220 0/3000 VA 100/120/ 230 Vac / 50 0 VA 100 Vac Tower Prod uct Over view Front panel fea tures Rear p anel f eatu res 50 0 V A to 15 00 V A mod els 1 Di spla y inte rface 500/750/1000/ 1500 V A 2200/3000 V A 2 Be zel 3 Ba tte ry 4 Inte rnal b attery c onnect or 1 USB port 500/750 V A 100 V ac 750 V A 120 V ac 750 V A [...]
-
Page 6
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 4 Rear p anel f eatu res 22 00 V A and 3 000 V A mo dels Inst allat ion For UPS inst all ation inform at ion, refer to the Smart-UPS I ns tal lati on Guide 7 50/1000/ 1500/2200/ 3000 V A 100/120/ 230 V ac, 500 V A 100 V ac T ower, that i s incl uded with the UPS. The [...]
-
Page 7
5 Smar t- UPS 750/1 000/1500/ 220 0/3000 VA 100/120/ 230 Vac / 50 0 VA 100 Vac Tower Operat ion Conn ect Eq uipm ent Note: The 2200/3000 V A 100 V ac model UPS wil l char ge to 9 0% capacity i n the fi rst four and a ha lf hours of norm al ope ra tion. All oth er models will ch ar ge to 90% capacit y in the first th ree hours of normal ope ration D[...]
-
Page 8
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 6 Displa y Panel Usi ng th e dis p l ay in ter face Us e t he U P / D OWN arro w butto ns to s croll throug h the m ain men u opti ons. Pr ess ENTER to vi ew the submenus unde r each main menu optio n. Press ESC APE t o ex i t a s u b menu and ret urn to a m ain men u[...]
-
Page 9
7 Smar t- UPS 750/1 000/1500/ 220 0/3000 VA 100/120/ 230 Vac / 50 0 VA 100 Vac Tower Ad van ced me nu s The Advan ce d men us provide additi onal opti ons f or the UPS and ar e availabl e only if the dis play int erfa ce i s configu red to use the Adva nced menus. Me nu Ge ne r a l Fun c ti on s St a t u s V i ew det ail ed UPS infor mat io n: • [...]
-
Page 10
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 8 Config uration UP S Sett ing s St a rt up Settings Configure the se se ttings at i nitia l st art up, usin g the dis play i nterface . As a n alt ernat ive, co nfigurat ion c an be perform ed using PowerChut e ™ software. Note: Dur ing s tart up, u se the dis play[...]
-
Page 11
9 Smar t- UPS 750/1 000/1500/ 220 0/3000 VA 100/120/ 230 Vac / 50 0 VA 100 Vac Tower Low T ran sfer Poi nt 100 V ac: 92 V ac 86 V ac - 92 V ac Set the tr ans fe r po int lo we r if th e u tilit y vol ta ge is chr onical ly low an d the conn ect ed equipm en t can tole ra te t his c o ndi tion .Th is set ting ma y also be ad jus ted usi ng the powe [...]
-
Page 12
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 10 Main Outlet Group and Controlle d Outle t Group Ov ervi ew The Main Outle t Group and the Control led Outle t Group can be configure d to inde penden tly turn of f, turn on, s hut down , and reboot conn ected equi pment. (These fe atures ar e not a vai lable on the[...]
-
Page 13
11 Smar t-UPS 750/1000/ 1500/220 0/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower Cu stom iz e t he M a in and C ont roll ed Ou tl et G ro ups Us e t he Configuration menus to change t he Ma in Outlet Group and the Controll ed Outlet Group se tt ings. N etw or k Ma na ge ment C ard Set ti n gs These se ttings a re availa ble onl y on units t hat ha[...]
-
Page 14
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 12 Emergen cy Power Of f Ov ervi ew The Emerge ncy Power Off (E P O) optio n, is a safety fe ature th at wil l immediate ly di s connect al l connecte d equipm ent f rom util ity power . The UPS will imme diate ly shut down and will no t switc h to batte ry power . Ad[...]
-
Page 15
13 Smar t-UPS 750/1000/ 1500/220 0/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower T rou bleshoot ing Pr oblem and Po ssible Cause Solution The UPS w ill n o t turn on o r t here is n o ou tp ut The uni t has not b een tur ned on. Pre ss the O N key once to tur n on the UPS. Th e U PS is not con n e ct ed t o util it y po w e r . Be sure th e powe r[...]
-
Page 16
Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/ 230 Vac / 500 VA 100 Vac Towe r 14 Se rvice If th e un it re q ui re s se r vi ce , d o no t retur n it to t he d e al er . Fol lo w t he se st eps: 1. Review the T r ouble shooti ng se ction of t h e ma nual to e limin at e co m mon pr obl em s. 2. If the proble m pe rsi s ts, conta ct APC by Schn [...]
-
Page 17
15 Smar t-UPS 750/1000/ 1500/220 0/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower T wo Y ear Limited Factor y W arr ant y Schneid er Electri c IT Corpora tion (SEIT ), war rants its pr oduc ts to be free from defect s in material s and workmanshi p fo r a per iod of t hree (3) yea r s e xcludi ng t he bat te ries, whi ch are wa rran ted for two (2)[...]
-
Page 18
03/20 13 EN 990- 3534 D APC by Schne ider Electric World wide Cust omer Support Customer suppor t for this or any othe r APC by Schneider Ele ctric product is avail able at no char ge in any of the followi ng ways: • V isit the APC by Schneider Elec tric W eb site to acces s documen ts in the APC by Schne ide r Electric Knowledg e B ase and to su[...]