Tripp Lite 220/380 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Tripp Lite 220/380, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Tripp Lite 220/380 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Tripp Lite 220/380. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Tripp Lite 220/380 should contain:
- informations concerning technical data of Tripp Lite 220/380
- name of the manufacturer and a year of construction of the Tripp Lite 220/380 item
- rules of operation, control and maintenance of the Tripp Lite 220/380 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Tripp Lite 220/380 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Tripp Lite 220/380, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Tripp Lite service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Tripp Lite 220/380.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Tripp Lite 220/380 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Owner’ s Man ual 1111 W. 35th Street • Chicago, IL 60609 USA (773) 869-1234 • www .tripplite.com Copyright ©2005 T ripp Lite. All rights reserved. SmartOnline™ is a trademark of Tripp Lite. Smar tOnline ™ 3-Phase 20kV A & 30kV A Intellig ent T rue On-Line UPS Systems Input/Output* V oltage: 220/380, 230/400, 240/415V AC, 3ø, 4 wire [...]

  • Page 2

    2 Impor tant Safety W arnings SA VE THESE INSTRUCTIONS. This manual contains important instructions and warnings that should be followed during the installation and maintenance of all T ripp Lite SmartOnline 3-Phase 20kV A and 30kV A UPS Systems and their batteries. UPS Location W arnings • Install your UPS indoors, away from heat, direct sunligh[...]

  • Page 3

    1 2 3 4 13 12 7 10 11 9 8 5 6 3 Contr ol P anel There are two separate UPS system modules: a power module and a battery module. Familiarize yourself with the location and function of the features on each module before installing and operating your UPS system. The power module is the only module which includes front panel features. FRONT P ANEL 1. ?[...]

  • Page 4

    4 Rear P anels 1. Manual Bypass Switch: This dial is used in one step of putting the UPS in "BYP ASS” mode, which must be done before performing any maintenance on the UPS with the connected load supported. [See “Operation (Special Conditions)” for step-by-step instructions for going into “BYP ASS.”] While this switch is on “BYP AS[...]

  • Page 5

    5 Rear P anels (continued) Refer to the Battery Module's Owner's Manual f or all safety warnings and connection instructions. 14. Fuse Holder (externally accessible): fuses protect against short circuit damage. If a heavy overload or short circuit is encountered, a fuse will blow . A Battery Module with a blown fuse will not deliver any o[...]

  • Page 6

    6 Installation UPS LOCA TION Move your UPS over short distances using its wheels. Stabilize the UPS by releasing the stabilizers on each side of the unit. N OTE: Do not stack the UPS System power module or external battery modules. UPS PO WER MODULE INPUT AND OUTPUT HARD WIRE CONNECTION In addition to the instructions listed below , follow all warn[...]

  • Page 7

    7 Installation (continued) Operation (Normal Conditions) TURNING THE UPS ON • Make sure the UPS is properly installed (see Installation section) and the Manual Bypass Switch is set to NORMAL. • T urn the AC Input and Bypass AC Input Circuit Breakers ON. • If your AC input is providing power normally within your selected range, your connected [...]

  • Page 8

    8 Operation (Normal Conditions) (continued) SELF-TESTING When you turn the UPS ON, it will perform a brief self-test. See charts below for display sequences. Display sequence when AC input power is present: Display sequence when AC input power is absent: SELF TESTING ... (possible only with the "Battery Start" Switch) RECTIFIER OK SELF TE[...]

  • Page 9

    9 INVERTER ON W ARNINGS When the inverter is ON, the LCD Display may show any one of the following warnings: Condition LCD Display Message UPS Output Overload OVERLOAD 1 10% UPS Charger Failure CHARGER F AILURE Abnormal Input Frequency FREQUENCY ERROR Abnormal Input Phase PHASE ABNORMAL! Battery is Depleting* ON BA TTER Y Battery Charge is Nearly D[...]

  • Page 10

    10 Condition LCD Display Message Overload Shutdown ON BYP ASS OVERLOAD 150% SHUTDOWN... VERSION: XXXXXXX UPS Output Short Circuit ON BYP ASS SHOR T CIRCUIT! SHUTDOWN... VERSION: XXXXXXX Overtemperature ON BYP ASS HIGH TEMP! SHUTDOWN... VERSION: XXXXXXX DC BUS Overvoltage ON BYP ASS DC BUS O.V .P .! SHUTDOWN... VERSION: XXXXXXX DC BUS Failure ON BYP[...]

  • Page 11

    DR Y CONT ACT INTERF A CE This female DB9 contact-closure port allows your UPS to send contact-closure signals to indicate that it is in battery back-up mode and that its batteries are running low . The port can also receive a remote shutdown signal. DR Y CONT ACT INTERF ACE T ABLE UPS Operating Mode Pin 8,3 Pin 1,3 Normal OPEN OPEN Back Up CLOSE *[...]

  • Page 12

    12 Comm unications (continued) REMO TE EMERGENCY PO WER OFF (EPO) This optional feature is only for those applications which require connection to a facility's Emergency Power Of f (EPO) circuit . When the power module is connected to this circuit, it enables emergency shutdown of the output. Using the included cable, connect the p ower mod- u[...]

  • Page 13

    Model: SU20K3/3X Includes: • Power Module • Battery Module Model: SU20K3/3INTPM Model: BP240V33 Input Input V oltage: 220/380, 230/400, 240/415V AC , 3ø , 4 wire (plus ground), wye Input F requency 50/60 Hz ± 3 Hz (auto-selectable) V oltage Correction Range: 156-280/270-485V A C Input Current (P er Phase, On-Line) 30A/29A/28A Inrush Current &[...]

  • Page 14

    1111 W . 35th Street, Chicago, IL 60609 USA 773.869.1234 (USA) • 773.869.1212 (International) www .tripplite.com 2009XXXXX 93-2260_ES[...]