Similar user manuals
-
Power Supply
Tripp Lite RV1512UL
4 pages 0.12 mb -
Power Supply
Tripp Lite PR 25
4 pages 0.05 mb -
Power Supply
Tripp Lite UL1778
24 pages 0.34 mb -
Power Supply
Tripp Lite SU6000XFMR
17 pages 0.58 mb -
Power Supply
Tripp Lite SMART2200RM2U
64 pages 14.08 mb -
Power Supply
Tripp Lite XL INT 3000
7 pages 0.28 mb -
Power Supply
Tripp Lite Switched Rack PDU
10 pages 0.86 mb -
Power Supply
Tripp Lite RBC49-2U
2 pages 0.11 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Tripp Lite Omni VS UPS Systems OMNIVS1000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Tripp Lite Omni VS UPS Systems OMNIVS1000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Tripp Lite Omni VS UPS Systems OMNIVS1000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Tripp Lite Omni VS UPS Systems OMNIVS1000 should contain:
- informations concerning technical data of Tripp Lite Omni VS UPS Systems OMNIVS1000
- name of the manufacturer and a year of construction of the Tripp Lite Omni VS UPS Systems OMNIVS1000 item
- rules of operation, control and maintenance of the Tripp Lite Omni VS UPS Systems OMNIVS1000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Tripp Lite Omni VS UPS Systems OMNIVS1000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Tripp Lite Omni VS UPS Systems OMNIVS1000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Tripp Lite service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Tripp Lite Omni VS UPS Systems OMNIVS1000.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Tripp Lite Omni VS UPS Systems OMNIVS1000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Owner’ s Manual 1111 W. 35th Street Chicago, IL 60609 USA Customer Support: (773) 869-1234 • www .tripplite.com Impor tant Safety Instructions 2 Quic k Installation 3 Basic Operation 4 Storage & Service 7 W arranty Registration 7 Omni VS UPS Systems Copyright © 2007 T ripp Lite. All rights reserved. Español 8 Français 16 W ARRANTY REGIST[...]
-
Page 2
Impor tant Safety Instructions 2 UPS Location W arnings • Install the UPS indoors, away from excess moisture or heat, dust or direct sunlight. • For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C). • Leave adequate space around all sides of the UPS for proper ventilation. • Do not mount unit with [...]
-
Page 3
3 Quic k Installation Connect the UPS to a 120V A C electrical outlet. Make sure the outlet does not share a circuit with a heavy electrical load such as an air conditioner or refrigerator . Plug y our equipment into the UPS. The battery backup receptacles A provide filtered AC power during normal operation and provide battery backup power during b[...]
-
Page 4
4 These connections are optional. The UPS will function properly without these connections. Phone Line/Netw ork Line Surge Suppression The UPS has jacks which protect against surges over a phone line or network data line. Using telephone cords or network data cables as appropriate, connect the wall jack to the UPS jack marked “IN.” Connect equi[...]
-
Page 5
5 MUTE/TEST Button: Silence the UPS On-Battery Alarm: Press and hold this button to silence the UPS on-battery alarm, a series of short beeps followed by a brief pause that is activated when the UPS is providing AC power from battery . Note: When the battery is nearly depleted, the low battery alarm—a continuous beep that cannot be silenced—wil[...]
-
Page 6
6 AC Outlets: The battery backup receptacles provide filtered AC power during normal operation and provide battery backup power during blackouts and extreme voltage irregularities. Connect your computer and monitor to the battery backup receptacles. One or more surge-only receptacles B attached to short cords at the rear of the UPS provide AC line [...]
-
Page 7
7 Storage All connected equipment should be turned off, then disconnected from the UPS to avoid battery drain. Unplug the UPS from its AC receptacle, then press and hold its ON/OFF button to deactivate it. The UPS is now ready for storage. When storing the UPS for an extended period of time, fully recharge the UPS batteries once every three months [...]
-
Page 8
Manual de operación 1111 W. 35th Street Chicago, IL 60609 EE.UU. Asistencia al cliente: +1 (773) 869-1234 • www .tripplite.com Impor tantes instrucciones de seguridad 9 Instalación rápida 10 Operación básica 11 Almacenamiento y servicio 15 Sistemas UPS Omni VS © 2007 T ripp Lite. T odos los derechos reservados. English 1 Français 16 No con[...]
-
Page 9
9 Advertencias sobre la ubicación del UPS • Instale el sistema UPS bajo techo, alejado del calor o la humedad excesivos, del polvo o de la luz solar directa. • Para lograr el mejor rendimiento, mantenga la temperatura interior entre 0º C y 40º C (32º F y 104º F). • Mantenga espacio suficiente alrededor del sistema UPS para permitir una v[...]
-
Page 10
Instalación rápida Conecte el sistema UPS a una toma de corriente de la CA 120V . Conecte el UPS en una toma de corriente que no comparta el circuito con ninguna carga eléctrica pesada como un equipo de aire acondicionado o un refrigerador . Conecte sus equipos con el UPS. Los receptáculos de reserva de la batería de la UPS proporcionan corrie[...]
-
Page 11
11 Use el botón ON/OFF (encendido y apagado) para hacer lo siguiente: Cambiar el modo de operación del UPS: Mientras el UPS está enchufado a una toma de CA accionada, oprima el botón ON/OFF (encendido y apagado) hasta que se oiga un sonido (aproximadamente 2 segundos) para alternar entre ON y OFF . • Modo de ON: HABILIT A el respaldo de bater[...]
-
Page 12
Use el botón MUTE/TEST (silenciar / probar) para hacer lo siguiente: Silenciar la alarma del UPS en batería: Oprima y mantenga este botón para silenciar la alarma del UPS en batería. Se oirá entonces una serie de sonidos cortos a los cuales les seguirá una breve pausa que se activa cuando el UPS proporciona CA por medio de la batería. Nota: [...]
-
Page 13
13 Salidas de corriente alterna: Los receptáculos de reserva de la batería de la UPS proporcionan corriente alterna filtrada durante la operación normal y proporcionan energía de reserva de la batería durante apagones e irregularidades extremas del voltaje. Conecte su computadora y monitor con los receptáculos de la reserva de la batería. Un[...]
-
Page 14
en www .tripplite.com/support/battery/index.cfm para localizar la batería de reemplazo específica para su UPS. Ajuste de la sensibilidad de la energía eléctrica: Este indicador normalmente está ajustado totalmente en sentido contrario a las manecillas del reloj; ello permite proteger al UPS de distorsiones en el modo de onda presentes en la en[...]
-
Page 15
NOTIFICA CIÓN DEL COMITÉ FEDERAL DE COMUNICACIONES (FCC) SOBRE INTERFERENCIAS DE RADIO Y TELEVISIÓN: Nota: Este equipo se ha probado y cumple con los límites para dispositivos digitales de Clase B , en conformidad con la Parte 15 de las reglas de la FCC. Estos límites están diseñados para proporcionar una protección razonab le en contra de [...]
-
Page 16
Guide de l'utilisateur 1111 W. 35th Street Chicago, IL 60609 USA Service à la clientèle : +1 (773) 869-1234 • www .tripplite.com Impor tantes consignes de sécurité 17 Installation rapide 18 Exploitation de base 19 Entreposage et entretien 23 Systèmes UPS Omni VS © 2007 T ripp Lite. T ous droits réservés. English 1 Español 8 Non appr[...]
-
Page 17
17 Mises en gar de relatives à l'emplacement du système UPS • Installez votre système UPS à l'intérieur , loin de l'humidité, de la chaleur excessive, de la poussière et de la lumière directe du soleil. • Pour un meilleur fonctionnement, maintenez la température ambiante entre 0º C et 40º C (32º F et 104º F). • Lai[...]
-
Page 18
18 18 Installation rapide Branchez v otre système UPS dans une prise de secteur de C.A. 120V . Branchez le UPS dans une prise qui ne partage pas son circuit avec une lourde charge électrique comme un climatiseur ou un réfrigérateur . Brancher v otre équipement au système d'alimentation continue sans coupure . Les réceptacles de secours [...]
-
Page 19
19 Le commutateur “ ON/OFF ” (marche/arrêt) : Changement du mode de fonctionnement du système UPS : Le système UPS étant branché dans une prise c.a., appuyez sur le commutateur “ ON/OFF ” en le maintenant enfoncé jusqu'à ce que vous entendiez un timbre (pendant environ 2 secondes) indiquant qu'il vous est possible de bascul[...]
-
Page 20
20 Arrêt de l'alarme de la batterie du système UPS : Appuyez sur le commutateur et maintenez-le enfoncé pour mettre l'alarme de la batterie du système UPS hors fonction; celle-ci émet une série de courts signaux suivis d'une brève pause lorsque l'alimentation électrique c.a. est fournie par la batterie. Note : Lorsque la[...]
-
Page 21
21 Sorties CA: Les réceptacles de secours de batterie de l'UPS fournissent le courant alternatif filtré pendant l'opération normale et fournissent la puissance de secours de batterie pendant des arrêts totales et des irrégularités extrêmes de tension. Reliez votre ordinateur et moniteur aux réceptacles de secours de batterie. Un o[...]
-
Page 22
batterie initiale de votre système UPS durera plusieurs années. Le remplacement de la batterie ne doit être réalisé que par du personnel de service qualifié. Référezvous à la rubrique “ Mises en garde relatives à la batterie ” à la section Sécurité. Si votre UPS nécessite un remplacement de batterie, rendez visite à T ripp Lite s[...]
-
Page 23
A VIS D'INTERFÉRENCE TV / RADIO DE LA FCC : Note : Ce matériel a été testé et s'est avéré être conforme aux limites des dispositifs numériques de Classe B, conf or mément à la P ar tie 15 du règlement de la FCC. Ces limites sont conçues pour fournir à une installation résidentielle une protection raisonnable contre les inte[...]
-
Page 24
200707074 93-2712 1111 W. 35th Street Chicago, IL 60609 USA Customer Support: (773) 869-1234 • www .tripplite.com 200707074 OwnersManual 93-2712 Omni VS Series update.qxd 8/17/2007 2:38 PM Page 24[...]