Go to page of
Similar user manuals
-
Power Supply
Tripp Lite SUPDM13
3 pages 0.11 mb -
Power Supply
Tripp Lite OMNIVS800
24 pages 0.84 mb -
Power Supply
Tripp Lite 6kVA
120 pages 6.29 mb -
Power Supply
Tripp Lite 277/480V AC
56 pages 4.34 mb -
Power Supply
Tripp Lite IEC-60320-C19
9 pages 1.33 mb -
Power Supply
Tripp Lite DCOW 2
1 pages 0.04 mb -
Power Supply
Tripp Lite BP192V557C-1PH
2 pages 0.07 mb -
Power Supply
Tripp Lite 700 HG
2 pages 0.11 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Tripp Lite Smart Pro 450 RT, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Tripp Lite Smart Pro 450 RT one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Tripp Lite Smart Pro 450 RT. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Tripp Lite Smart Pro 450 RT should contain:
- informations concerning technical data of Tripp Lite Smart Pro 450 RT
- name of the manufacturer and a year of construction of the Tripp Lite Smart Pro 450 RT item
- rules of operation, control and maintenance of the Tripp Lite Smart Pro 450 RT item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Tripp Lite Smart Pro 450 RT alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Tripp Lite Smart Pro 450 RT, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Tripp Lite service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Tripp Lite Smart Pro 450 RT.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Tripp Lite Smart Pro 450 RT item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 Copyright ©1999 Tripp Lite. All rights reserved. SmartPro ® is a registered trademark of Tripp Lite. 1111 W. 35th Street Chicago, IL 60609 USA Customer Support: (773) 869-1234 www.tripplite.com Installation: p. 3 - 4 Basic Operation: p. 5 - 7 Stora g e & Ser vice: p. 8 Specifications: p. 8 Safety: p. 2 Owner's Manual Smar tPr o ® 450 [...]
-
Page 2
2 This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. UPS Location W arnings • Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight. • For best performance, keep the indoor temperature between 32° F and 104[...]
-
Page 3
3 Mounting Note: When removing the mounting bracket screws to change the mounting profile of your UPS, do not remove the screws which secure the UPS cabinet. Two of these screws are located at each end of the UPS, between the four holes used for the mounting brackets. Rac kmount Your UPS’s mounting brackets are pre-set at a standard depth for 19-[...]
-
Page 4
4 Plug one end of the detachab le line cord into y our UPS's A C Inlet Receptac le and the other end into an electrical outlet. Plug y our computer , monitor and other critical devices into y our UPS's Battery-Suppor ted Receptac les.* Plug a printer or other peripheral equipment into y our UPS's Surge- Onl y Receptacle . –Optional[...]
-
Page 5
5 Switch 1. Main P o wer Switch This switch activates three separate UPS functions: UPS Power Press the switch, hold it for 3 seconds and release it to turn the UPS ON or OFF.* Alarm Silence Press the switch and immediately release it to silence the UPS Alarm. UPS Cold Start Press the switch, hold it for 5 seconds and release it to turn your UPS ON[...]
-
Page 6
6 Indicator Lights The SmartPro 450 RT utilizes dual function Indicator Lights that alert you to different information depending on whether they illuminate constantly or are flashing. All Indicator Light Descriptions refer to when the UPS is connected to the wall outlet and turned ON. 2. "A C Normal/A VR" LED This green light will illumin[...]
-
Page 7
7 Other UPS Features 7. A C Receptac les (Batter y Bac kup Suppor ted) These receptacles provide your connected equipment with AC line power during normal operation and battery power during blackouts and brownouts. They also protect your equipment against damaging surges and line noise. Connect com- puter, monitor and other essential equipment to t[...]
-
Page 8
8 Specifications Storage & Ser vice Stora ge First turn your UPS OFF and disconnect its power cord from the wall outlet. Then disconnect all equipment to avoid battery drain. If you plan on storing your UPS for an extended period of time, fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet, turning[...]
-
Page 9
9 1111 W. 35th Street Chicago, IL 60609 USA www.tripplite.com Manual de Operación Smar tPr o ® 450 R T Sistema UPS/No-break Inteligente para Redes (120 V) Instalación: páginas 11 - 12 Operación Básica: páginas 13 - 15 Almacenaje y Ser vicio: página 16 Especificaciones: página 16 Seguridad: página 10 9904216 Smart 450 RT Owners Manual [120[...]
-
Page 10
10 Este manual contiene instrucciones y advertencias importantes que deben seguirse durante la instalación, operación y almacenaje de todos los Sistemas UPS/No-breaks de Tripp Lite. Advertencias sobre la Instalación del Sistema UPS/No-break • Instale el Sistema UPS/No-break bajo techo en un lugar sin humedad, calor excesivo, polvo o luz solar [...]
-
Page 11
11 Montaje Nota: Cuando remueva los tornillos de los soportes de montaje para cambiar el perfil de montura de este Sistema UPS/ No-break, no remueva los tornillos que sujetan el gabinete del Sistema UPS/No-break. Dos de estos tornillos están ubicados en cada extremo del Sistema UPS/No-break, entre los cuatro agujeros usados para los soportes de mo[...]
-
Page 12
12 Conecte un extremo del cab le principal desmontable al Receptáculo de Entrada de CA del Sistema UPS/ No-break y el otr o extremo a un enchuf e eléctrico. Conecte la computadora, monitor y otr os dispositiv os críticos a los Receptáculos con Energía de Respaldo del Sistema UPS/No-break.* Conecte impresoras u otr os equipos periféricos al Re[...]
-
Page 13
13 Interruptor 1. Interruptor Principal Este interruptor activa tres funciones separadas del Sistema UPS/No-break: Encendido y Apagado Oprima este interruptor, sosténgalo por 3 segundos y suéltelo para encender y apagar (ON/OFF) el Sistema UPS/No-break.* Silenciador de Alarma Oprima este interruptor y suéltelo inmediatamente para silenciar la al[...]
-
Page 14
14 Luces Indicadoras El SmartPro 450 RT utiliza luces indicadoras de doble función para porporcionar información sobre condiciones diferentes de operación de acuerdo a la estructura de iluminación (constante o parpadeante) de estas luces. Todas la Descripciones de las Luces Indicadoras asumen que el Sistema UPS/No-break está conectado a una l?[...]
-
Page 15
15 Otras Características del Sistema UPS/No-break 7. Receptáculos de CA (Respaldados por la Batería de Respaldo) Estos receptáculos proporcionan energía de línea de CA a los equipos conectados durante condiciones normales de operación, y energía de batería durante apagones y caídas de voltaje. También protegen sus equipos contra los dañ[...]
-
Page 16
16 Especificaciones Amacenaje y Ser vicio Almacenaje Apague (OFF) el Sistema UPS/No-break y desconecte el cable principal del enchufe de la pared. Desconecte todos los equipos para evitar el desgaste de la batería. Si usted desea almacenar el Sistema UPS/No-break por un período prolongado de tiempo, cargue totalmente la batería del Sistema UPS/N[...]
-
Page 17
17 1111 W. 35th Street Chicago, IL 60609 USA www.tripplite.com Man uel de l’Utilisateur Smar tPr o ® 450 R T Système d’UPS à Réseau Intelligent (120V) Installation: p. 19 - 20 Opération de base: p. 21 - 23 Entreposage & Service: p. 24 Caractéristiques: p. 24 Sûreté: p. 18 9904216 Smart 450 RT Owners Manual [120 Volt].p65 3/13/00, 3:[...]
-
Page 18
18 Ce manuel contient des instructions et recommandations importantes qui doivent être suivies durant l’installation, l’opération et l’entreposage de tous les Systèmes d’UPS de Tripp Lite. Recommandations relatives à l’Emplacement de l’UPS • Installez votre UPS à l’intérieur, loin de l’humidité excessive ou de la chaleur, l[...]
-
Page 19
19 Monta g e Note: En retirant les vis de support pour changer le profil de support de votre UPS, ne retirez pas les vis qui fixent le modul e de l’UPS. Deux de ces vis sont placées à chaque extrémité de l’UPS, entre les quatre trous utilisés pour les supports. Monta g e en ver sion Rac k Vos supports de montage de l’UPS sont pré-établ[...]
-
Page 20
20 Branc hez une des extrémités de la prise du cor don de ligne détachab le dans le réceptac le de la prise C.A. de v otre UPS, et l’autre e xtrémité dans une sor tie électrique . Branc hez v otre or dinateur , moniteur et autres dispositifs critiques dans les réceptac les “Batter y- Suppor ted” de v otre UPS.* Branc hez une imprimant[...]
-
Page 21
21 Comm utateur 1. Comm utateur d’ “Alimentation Principale” Ce commutateur lance trois fonctions séparées de l’UPS: Alimentation de l’UPS Pressez le commutateur, retenez le pendant 3 secondes et libérez le pour ajuster l’UPS sur la position ON ou OFF.* Amortissage de l’Alarme Pressez le commutateur et libérez le immédiatement po[...]
-
Page 22
22 V o y ants de Signalisation Le SmartPro 450 RT utilise une double fonction de Voyants de Signalisation vous alertant des différentes informations à savoir s’ils illuminent constamment ou flashent. Toutes les descriptions du Voyant de Signalisation s’appliquent à savoir quand l’UPS est relié à la prise murale et positionné sur ON. 2. [...]
-
Page 23
23 A utres Dispositifs d'UPS 7. Réceptac les C.A. (Sauvegar de de Batterie Suppor tée) Ces réceptacles fournissent à votre matériel relié à la puissance de ligne C.A. pendant l’exécution normale et la puissance de batterie pendant des arrêts totaux et des arrêts partiels. Ils protègent également votre matériel contre les surtens[...]
-
Page 24
24 Caracteristiques Entreposa g e & Service Entreposa g e Arrêtez d’abord votre UPS et déconnectez son cordon de secteur de la prise murale. Débranchez ensuite tout le matériel pour éviter l’écoulement de la batterie. Si vous envisagez d’entreposer votre UPS pendant une longue période, rechargez entièrement les batteries de l’UP[...]