TriStar SP3007EEAZ manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of TriStar SP3007EEAZ, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of TriStar SP3007EEAZ one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of TriStar SP3007EEAZ. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of TriStar SP3007EEAZ should contain:
- informations concerning technical data of TriStar SP3007EEAZ
- name of the manufacturer and a year of construction of the TriStar SP3007EEAZ item
- rules of operation, control and maintenance of the TriStar SP3007EEAZ item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of TriStar SP3007EEAZ alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of TriStar SP3007EEAZ, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the TriStar service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of TriStar SP3007EEAZ.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the TriStar SP3007EEAZ item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS P/N: IS32 00 Rev. D __________________________________________________________________________________________ OWNER’S M ANUAL INSTALLATION, OPERATION, & PART S * 50HZ Mode ls are not UL Liste d. TriStar ™ Pump Series The Hayward TriStar Pum p is specifically engineered for the [...]

  • Page 2

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ____________________ _____________________________Page 2 of 15 IMPORTANT SAFETY I NSTRUCTIONS Before installing or se rvicing this electrical equipment, turn power su pply OFF. WARNI NG – Read and follow all instructions in this owner’s manual and on th e equ[...]

  • Page 3

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series __________ _____ ________________________________Page 3 of 15 WARNING – It is required that license d electricians do all electrical wiring. Risk of Electric Shock. Hazardous voltage can shock, burn, an d cause death or serious property damage. To reduce the ri[...]

  • Page 4

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series __________ _____ ______________________________ Page 4 of 15 WARNING – Hazardous Pressure. Pool and s pa water ci rculation syst ems operate un der hazardous pressure during s tart-up, normal operation, and af ter pump shut- off. Stand clear of circulation syst[...]

  • Page 5

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series__________ _____ ______________________________ Page 5 of 15 Produc t Specific ations Install ation Instruct ions WARNING – This product should be ins talled and serviced on ly by a qu alified profess ional. P u m p L o c a t i o n Locate filt er as close to poo[...]

  • Page 6

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series __________ _____ _______________________________ Page 6 of 15 Pump Mounting (cont’d.) WARNING – Hazardous Pressure. Pum ps, filters, and other equipment/ components of a swimming pool f iltration system operate under press ure. Incorrectly ins talled and/or i[...]

  • Page 7

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series __________ _____ _______________________________ Page 7 of 15 Electrical ( cont’d.) Voltage Voltage at motor MUS T NO T be m ore than 10% abov e or below mot or name plate rated v oltage, or motor m ay overheat, caus ing overl oad tripping an d reduced compon e[...]

  • Page 8

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ ______________________________Page 8 of 15 WARNING – All suction and discharge valves MU S T be OPE N , as well as filter air relief valve (if av ailable) on filter, when starting the circulating pum p system. Failure to do so could res ult [...]

  • Page 9

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ ______________________________Page 9 of 15 Storage/Winterizat ion WARNING – Separation Hazard. Do not purge the system with compressed air. Purging the system wi th co mpressed air can cause components to ex plode, with risk of sev ere injur[...]

  • Page 10

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ ______________________________ Page 10 of 15 Removing the Impeller (See Parts D iagram on page 11 of thi s manual for pum p component locations.) 3. Remove the motor can opy by removing the tw o (2) screws and pu lling the canopy aw ay from th[...]

  • Page 11

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ _____________________________Page 11 of 15 Replacement Parts Parts Diagram Parts Listing Ref. No. Part No. Description Ctn. Qty. 1 SPX 3200UNKIT Union Connector Kit (Inc l udes Union Nut, Union Connec tor, Union Gasket - 2 ea.) 1 2 SPX3200UG U[...]

  • Page 12

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ _________________________ Page 12 of 15 Parts Listing (cont’d.) Ref. No. Part No. Description Ctn. Qty. 12 SP X3205C Impeller for ½ HP with Impeller Screw 10 SPX3207C Impeller for ¾ HP with Impeller Screw 10 SPX3207CM Impel l e r for 1 HP [...]

  • Page 13

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ____________________P age 13 of 15 Trouble shootin g Motor Will NOT St art – Check For: Make sure the terminal board connections agree with the wiring diagram on motor data plate label. Be sure motor is wired for avail able field su pply voltage (see pum p oper[...]

  • Page 14

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ ____________________________ Page 14 of 15 Low Flow – Generally, Check For: (cont’d.) 2. Undersi zed pool piping . Solution: Correct piping size. 3. Plugged or restricted discharge line of filter, valve partially closed (high gauge reading[...]

  • Page 15

    WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series Page 15 of 15 ▲ Retain this Warranty Certificate ( upper portio n) in a safe a nd convenient l ocation for y our records. ▼ DETACH HERE: Fill ou t bottom portion completely and mail within 10 days of p urchase/installa tion, or register online at WWW .HAY WAR[...]