Troy-Bilt MXZ-3A30NA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Troy-Bilt MXZ-3A30NA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Troy-Bilt MXZ-3A30NA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Troy-Bilt MXZ-3A30NA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Troy-Bilt MXZ-3A30NA should contain:
- informations concerning technical data of Troy-Bilt MXZ-3A30NA
- name of the manufacturer and a year of construction of the Troy-Bilt MXZ-3A30NA item
- rules of operation, control and maintenance of the Troy-Bilt MXZ-3A30NA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Troy-Bilt MXZ-3A30NA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Troy-Bilt MXZ-3A30NA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Troy-Bilt service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Troy-Bilt MXZ-3A30NA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Troy-Bilt MXZ-3A30NA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST ALLA TION MANUAL FOR INST ALLER CONTENTS 1. BEFORE INST ALLA TION ..............................................................................2 2. OUTDOOR UNIT INST ALLA TION .................................................................5 3. FLARING WORK AND PIPE CONNECTION .................................................7 4. PURGING PRO[...]

  • Page 2

    2 1. BEFORE INST ALLA TION 1-1. THE FOLLOWING SHOULD AL W A YS BE OBSERVED FOR SAFETY • Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner. • Besuretoobservethewarningsandcautionsspeciedhereastheyincludeimportantitemsrelatedtosaf[...]

  • Page 3

    3 2. Front (blowing) side open As long as space lik e the one showninthegurecanbe maintained, it does not mat- ter if there are obstacles in three directions (but top side isopen). 4. Obstacles on front and rear side only Theunitcanbeusedbyat - taching an optional outdoor blowin gguide (MAC-8 55SG)[...]

  • Page 4

    4 1-6. INST ALLA TION DIAGRAM Unitsshouldbeinstalledbylicensedcontractoraccordingtolocalcoderequirements. Aftertheleaktest,applyinsulat - ingmaterialtightlysothatthereis no gap. When the piping is to be at- tached to a wall containing metals (tinplated)ormetalnetting,?[...]

  • Page 5

    5 2. OUTDOOR UNIT INST ALLA TION 2-1. INST ALLING THE UNIT • Besuretoxtheunit’slegswithboltswheninstallingit. • Besuretoinstalltheunitrmlytoensurethatitdoesnotfallbyanearthquakeoragust. • Refertothegureintherightf[...]

  • Page 6

    6 A disconnectswitchmayberequired.Checkthelocalcode. Remark: *Adisconnectswitchmayberequired.Checkthelocalcode. ** Use a ring tongue terminal in order to connect a ground wire to terminal. INDOOR UNIT A Terminal block Grounding terminal ** INDOOR UNIT B Terminal block Grounding terminal **[...]

  • Page 7

    7 Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 3. FLARING WORK AND PIPE CONNECTION 3-1. FLARING WORK Pipe diameter [mm(inch)] Nut (mm) A [mm (inch)] T ightening torque Clutchtypetool for R410A Clutch typetool for R22 Wingnuttypetool for R22 N•m kgf•cm ft·Ib ø6.35(1/4) 17 0 to 0.5 (0.to0.02) 1.0 [...]

  • Page 8

    8 4-2. GAS CHARGE Perform gas charge to unit. 1 Connectgascylindertotheserviceportofstopvalve. 2 Perform air purge of the pipe (or hose) coming from refrigerant gas cylinder. 3 Replenish specied  amount of the refrigerant, while operating the air?[...]

  • Page 9

    9 Procedure Pressthepiping/wiringcorrectionswitch(SW871)1minuteormoreafter turningonthepowersupply . • Correction completes in 10 to 15 minutes. When the correction is com - pleted, its result  is shown by LED indication. Details are described in the following table.[...]

  • Page 10

    10 SG79Y871H02.indb 10 9/7/2007 1:09:46 PM[...]

  • Page 11

    MANUAL DE INST ALACIÓN P ARA EL INST ALADOR ÍNDICE 1. ANTES DE LA INST ALACIÓN .....................................................................12 2. INST ALACIÓN DE LA UNIDAD EXTERIOR ................................................15 3. TRABAJOS DE ABOCARDADO Y CONEXIÓN DE TUBERÍAS .................17 4. PR OC E DI MI EN T OS D E P UR G[...]

  • Page 12

    12 1. ANTES DE LA INST ALACIÓN 1-1. POR RAZONES DE SEGURIDAD, DEBERÁ OBSER V ARSE SIEMPRE LO SIGUIENTE • Ant e s d e i ns t al ar el ac o nd i ci on a do r d e a i re , l ea at e nt a me nt e e l a p ar t ad o “ PO R R A ZO N ES D E S E GU R ID A D, D E BE R Á O BS E RV AR S E S IE M PR E L O S IG U IE N TE ” . • Observelosmensa[...]

  • Page 13

    13 1. Obstáculos por la parte superior Sihayobstáculosúnicamenteporla partetrasera,noimportasihayalgún obstáculoporencimadelaunidad talycomosemuestraenlasiguiente gura. 2. Parte frontal (ventilación) abierta Siempre que se mantenga libre un espacio como el que[...]

  • Page 14

    14 1-6. DIAGRAMA DE INST ALACIÓN Launidaddebeserinstaladaporelservicioocialdeacuerdoconlanormativalocal. Despuésdelapruebadefugas, aplique material aislante de modo que no queden huecos. Cuando los tubos deban instalar- se en una pared con contenido metálico(placasdelatón)?[...]

  • Page 15

    15 2-1. INST ALACIÓN DE LA UNIDAD • Asegúresedejarlospiesdelaunidadcontornilloscuandolainstale. • Asegúresedeinstalarrmementelaunidadparaevitarsudesprendimientoencasodeterremotooráfagadeviento. • Conrespectoalacimentaciónd[...]

  • Page 16

    16 Puede que sea necesario un interruptor de desconexión. Consulte la normativa local. Observación: * Puede que sea necesario un interruptor de desconexión. Consulte la normativa local. ** Utilice un terminal en anillo para conectar el cable de tierra al terminal. UNIDAD INTERIOR È Panel de terminales Terminal de tierra** UNIDAD INTERIOR É Pan[...]

  • Page 17

    17 Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 3. TRABAJOS DE ABOCARDADO Y CONEXIÓN DE TUBERÍAS 3-1. T AREAS DE ABOCARDAMIENTO Diámetrodeltubo [mm(plug.)] T uerca (mm) A [mm (plug.)] Par de torsión Herramienta tipo embra- gue para R410A Herramienta tipo embra- gue para R22 Herramienta tipo tuerca de mariposa para R22 N•m kgf?[...]

  • Page 18

    18 4-2. CARGA DE GAS Efectúe la carga de gas en la unidad. 1 Conecte el cilindro de gas a la abertura de servicio de la válvula de retención. 2 Purgue el  aire de la tubería (o manguera) procedente del cilindro del refrigerante. 3 Añada la cantidad de refrigera[...]

  • Page 19

    19 Procedimiento Mantenga presionado el interruptor de c orrección de tuberías/conexiones (SW871)1minutoomástrasconectarlaalimentación. • La corrección tarda entre 10 y 15 minutos en efectuarse. Cuando la correcciónhanalizado,su resultadosemuestrapor m[...]