Turbo Air TBD-1SB manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Turbo Air TBD-1SB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Turbo Air TBD-1SB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Turbo Air TBD-1SB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Turbo Air TBD-1SB should contain:
- informations concerning technical data of Turbo Air TBD-1SB
- name of the manufacturer and a year of construction of the Turbo Air TBD-1SB item
- rules of operation, control and maintenance of the Turbo Air TBD-1SB item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Turbo Air TBD-1SB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Turbo Air TBD-1SB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Turbo Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Turbo Air TBD-1SB.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Turbo Air TBD-1SB item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    T urbo air Speeds Up the P ace of Inno vation Beer Dispenser & Bac k-Bar Cooler Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! TBD-1SD, TBD-2SD, TBD-3SD, TBD-4SD(Stainless Steel) TBD-1SB, TBD-2SB, TBD-3SB, TBD-4SB(Black Paint) TCB-2SD,TCB-3SD, TCB-4SD(Stainless Steel)[...]

  • Page 2

    SPECIFICATIONS ........................................................................................... 2 SERIAL NUMBER ............................................................................................ 2 INSTALLATION OF THE CASTERS .................................................................3 Draft Arms Towers Installation Schema[...]

  • Page 3

    3 Turbo air INST ALLA TION OF THE CASTERS According to model, refer to the assembly position of casters. TCB-2SD, TBD-2SD, TBB-2SB, TBB-2SG TCB-3SD, TBD-3SD, TBB-3SB, TBB-3SG TCB-4SD, TBD-4SD, TBB-4SB, TBB-4SG ※ This picture is a plan view of bottom cabinets. CB is an abbreviation of the caster with a brake. Other casters don't have a brake.[...]

  • Page 4

    4 Turbo air BEER LINE & CO 2 LINE Installation Schematic Diagram * Assemble BEER LINE & CO 2 LINE as above drawing. Distributor Fixture CO 2 Line Beer Line#1 Beer Line#2 Beer #1 Beer #2 CO 2 TCB-2SD, TCB-3SD, TCB-4SD TBD-2SD, TBD-3SD, TBD-4SD TBD-2SB, TBD-3SB, TBD-4SB[...]

  • Page 5

    5 Turbo air CA UTION "IMPOR T ANT" On direct-draw dispensers the drain is located at the front of the cabinet. To plumb in the drain, connect 5/8” P.V.C. pipe to the 5/8” barbed fitting supplies with the unit. DIRECT DRA W * Don't pull out or Turn drain line.[...]

  • Page 6

    6 Turbo air CA UTION "IMPOR T ANT" 1. PO WER CORD - Be sure the power cord is connected to the proper voltage, and amps should be run before connecting power cord to outlet. - A protected circuit of the correct voltage and amperage must be run for connection of the line cord. - Unplug the unit, whenever performing maintenance functions or[...]

  • Page 7

    7 Turbo air 1. GOOD AIR CIRCULA TION - Do not place any object that will restrict air flow in front or back grills. - Turbo air highly recommends that there is ample space in rear of unit. 3 inches or more is best. 2. PLA CE ON STR ONG GROUND - Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and cont[...]

  • Page 8

    8 Turbo air CLEANING Before cleaning, unplug the unit. 1. CLEANING THE INTERIOR AND EXTERIOR - The interior and exterior of the unit can be cleaned using warm water with soap. - Do not use an abrasive cleaner because it will scratch the surface. 2. CLEANING THE CONDENSER FINS - To maintain proper refrigeration performance, the Condenser coil must b[...]

  • Page 9

    9 Turbo air B ASIC OPERA TION 1. The controller(thermostat) is located at the back right inside of the unit. 2. The factory setting maintains about 38 ˚ F(3 ˚ C) inside. 3. Set toward “counter clock wise” warmer temperature and “clock wise” for colder temperature. 4. The thermostat controls compressor’s cycling by sensing inside tempera[...]

  • Page 10

    10 Turbo air BEFORE REQUESTING SER VICE SYMPT OMS CA USES SOLUTIONS Cooler is freezing products The unit does not refrigerate at all. The unit does not refrigerate well. There is a loud noise. There are dew-dr ops on the unit exterior . There are dew-dr ops on the unit interior . • Thermostat set too cold. • There is a power connection failure [...]

  • Page 11

    11 Turbo air W arranty Claims All claims for labor or parts must be made directly through Turbo Air. If unit was manufactured more than one year, proof of purchase must be faxed in or sent with claim. All claims should include: model number of the unit, the serial number of the cabinet, and all pertinent information supporting the existence of the [...]

  • Page 12

    12 Turbo air What Is Not Co vered By This W arranty Turbo Air’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty. NO CONSEQUENTIAL DA[...]

  • Page 13

    13 Turbo air 1250 Victoria street CARSON, CA 90746 TEL: 310-900-1000 FAX: 310-900-1077 Toll Free: 1-800-627-0032 (U.S.A. In Canada) http://www.turboairinc.com[...]