Go to page of
Similar user manuals
-
Network Card
Tyco DIU 200
2 pages 0.13 mb -
Network Card
Tyco AC2000 VIPPS
2 pages 0.19 mb -
Network Card
Tyco Controller webEntry II
2 pages 0.09 mb -
Network Card
Tyco EIOC
2 pages 0.09 mb -
Network Card
Tyco KT-MOD-OUT16
2 pages 0.22 mb -
Network Card
Tyco Card Reader S610s
2 pages 0.09 mb -
Network Card
Tyco Software House AS0073-001
2 pages 0.51 mb -
Network Card
Tyco RM-DCM-2
2 pages 0.24 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Tyco DSC Power832 PC5O15, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Tyco DSC Power832 PC5O15 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Tyco DSC Power832 PC5O15. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Tyco DSC Power832 PC5O15 should contain:
- informations concerning technical data of Tyco DSC Power832 PC5O15
- name of the manufacturer and a year of construction of the Tyco DSC Power832 PC5O15 item
- rules of operation, control and maintenance of the Tyco DSC Power832 PC5O15 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Tyco DSC Power832 PC5O15 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Tyco DSC Power832 PC5O15, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Tyco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Tyco DSC Power832 PC5O15.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Tyco DSC Power832 PC5O15 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Instruction Manual PC 5 O1 5 WARNING This manual contains info r mation on limitations r ega r ding p r oduct use and function and info r mation on the limitations as to liability of the manufactu r e r . The enti r e manual should be ca r efully r ead.[...]
-
Page 2
WARNING Please Read Car efully Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. System Failures This system has been carefully designed to be as effective as possible. There are c[...]
-
Page 3
1 About Your Security System Your DSC Power832 Security System has been designed to provide you with the greatest possible flexibility and convenience. Read this manual carefully and have your installer instruct you on your system's operation and on which features have been implemented in your system. All users of this system should be equally[...]
-
Page 4
2 System Information Fill out the following information for future reference and store this manual in a safe place. Access Codes Your Master Code is: __________________________________________ Additional Access Codes: 01 __________________ 09 ____________________ 17 ____________________ 2 5 ________________ 02 __________________ 10 ________________[...]
-
Page 5
3 15 ___________________________________________ _____________________________________ 16 ___________________________________________ _____________________________________ 17 ___________________________________________ _____________________________________ 18 ___________________________________________ _____________________________________ 19 _____[...]
-
Page 6
4 Access Codes Access codes are used to arm and disarm the system. There are 37 access codes available: 1 master code, 32 regular access codes, 2 duress codes and 2 partition master codes. Ask your installer for more information on using the duress and partition master codes. Only the Master Code can be used to program additional security codes and[...]
-
Page 7
5 Alternate Arming Methods Away Arming Arming the system in the Away mode will have all interior zones and perimeter zones active. If motion is detected in the interior zones, or if one of the perimeter zones is violated, the alarm sequence will begin. To arm in the Away mode, enter your access code and exit the premises through a designated Exit/E[...]
-
Page 8
6 Disarming the System Disarming from an LED or LCD5501Z Keypad: Enter the premises through a designated Exit/Entry door; entering by any other door will sound an immediate alarm. As soon as the Exit/Entry door is opened, the keypad will beep to indicate that the system should be disarmed. Go to the keypad and enter your access code. If an error is[...]
-
Page 9
7 If An Alarm Sounds Fire Alarm If your system has been installed with fire detectors and the alarm sounds in a pulsing mode, follow your emergency evacuation plan immediately (see “Fire Escape Planning” on page 15). Intrusion Alarm If an intrusion alarm sounds, indicated by a continuous bell or siren, the alarm may be silenced by entering your[...]
-
Page 10
8 8 PC5508(Z), PC5516(Z) and PC5532(Z) Keypads: Press the keys on the number pad to view alarms or troubles, to Arm/ Disarm the system or to bypass zones. To exit, press [#]; to select a function, press [ ✱ ]. Ready Light (All keypads) : If the Ready light is ON, the system is ready for arming. If the Ready light is OFF, check to see that all doo[...]
-
Page 11
9 9 All Keypads: Function Keys (Stay, Away, Chime, Reset, Exit): If activated by your installer, these keys allow easy single button activation of the most commonly used features. For more information, talk to your alarm installer. Press both Keys for two seconds to send a FIRE transmission. Press both Keys for two seconds to send an AUXILIARY tran[...]
-
Page 12
10 LCD5500(Z) Keypad: The Liquid Crystal Display (LCD) displays prompts and system information on two 16 character lines. If “< >” appears, more information can be accessed by using the arrow (< >) keys. Press [<] to see the previous function or item of information. Press [>] to advance the display to next function or item of [...]
-
Page 13
11 Programming codes from an LCD Keypad: Master Code Press the [ ✱ ] key to enter the function list. Scroll (< >) to... Press [5] or [ ✱ ]. The display will read... Enter your current Master Code. The display will read... “01P” represents the first access code. Use the arrow (< >) keys to scroll to “40P” and press the [ ✱ [...]
-
Page 14
12 Zone Bypassing The zone bypassing function is used when access is needed to part of the protected area while the system is armed. Zones which are temporarily out of service due to damaged wiring or contacts may be bypassed to allow system arming until repairs can be made. Bypassed zones will not cause an alarm. Zones cannot be bypassed once the [...]
-
Page 15
13 Additional Zone Bypassing Features To recall the last set of bypassed zones, press [ ✱ ][1][9][9]. Arm the system. The Bypass light will turn on to indicate that zones are bypassed. To clear all bypassed zones, press [ ✱ ][1][0][0]. Viewing Trouble Conditions The control panel continuously monitors a number of possible trouble conditions. If[...]
-
Page 16
14 To view troubles from an LCD Keypad: From the Ready state, use the arrow (< >) keys to scroll to the following message. Press [ ✱ ] [2] to view the trouble. The message will read... Use the arrow (< >) keys to view which troubles are present on the system. Once you have scrolled through the list of troubles, press the [#] key to ex[...]
-
Page 17
15 5. If the panel has any fire zones, activation will cause the alarm signal to sound in a pulsed mode. CAUTION: Do not use an open flame or burning materials to test a smoke or heat detector. Contact your installer for information on safe methods of testing detectors. 6. When testing is complete, call and advise the central station. Should the sy[...]
-
Page 18
16 >) keys to scroll through all of the events in the buffer. When you have finished viewing the events, press [#] to exit. Downloading Enable To enable a six-hour downloading window from any system keypad, enter [ ✱ ] [6] [Master code] [5]. During this time, the panel will answer incoming downloading calls. For more information, please ask yo[...]
-
Page 19
17 Fire Escape Planning There is often very little time between the detection of a fire and the time it becomes deadly. It is thus very important that a family escape plan be developed and rehearsed. 1. Every family member should participate in developing the escape plan. 2. Study the possible escape routes from each location within the house. Sinc[...]
-
Page 20
18 NOTES[...]
-
Page 21
19 NOTES[...]
-
Page 22
AVIS: L’étiquette de l’Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme à certaines normes de protection, d’exploitation et de sécurité des réseaux de télécommunications. Industrie Canada n’assure toutefois pas que le matériel fonctionnera à la satisfaction de l’utilisate[...]
-
Page 23
[...]
-
Page 24
Digital Security Controls Ltd. ’ s liability for failure to repair the product under this warranty after a reasonable number of attempts will be limited to a replacement of the product, as the exclusive remedy for breach of warrant y . Under no circumstances shall Digi- tal Security Controls Ltd. be liable for any special, incidental, or conseque[...]