A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of U-Line ADA24R, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of U-Line ADA24R one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of U-Line ADA24R. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of U-Line ADA24R should contain:
- informations concerning technical data of U-Line ADA24R
- name of the manufacturer and a year of construction of the U-Line ADA24R item
- rules of operation, control and maintenance of the U-Line ADA24R item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of U-Line ADA24R alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of U-Line ADA24R, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the U-Line service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of U-Line ADA24R.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the U-Line ADA24R item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Use and Car e Guide ADA24R ADA24RGL ADA SERIES Refrigerator Models: ADA24[...]

  • Page 2

    ADA24 , ADA SERIES Congratulations on your purc hase of a U-Line refrigeratio n product. U-Lin e Co rporatio n, a pioneer in the applianc e industry for more than 40 years, is the world’ s number one manuf acturer of built-in, un dercounter , specialty refrigeration and ice making prod ucts. U- Line dedi cates 100% of its research and development[...]

  • Page 3

    ADA24 1 ADA SERIES ADA24 Introduction .. .............. ............ ........... .............. ........... ........... .............. ......... Inside Front Cov er Warranty Registration .................... ............ .. ......... ........... .............. ...... Inside Front Cover Please Record Your M odel Information ............ ............[...]

  • Page 4

    2 ADA24 ADA SERIES IMPORT ANT IMPORT ANT PLEASE READ all instruct ions completely before attempting to install, operate, or ser vice your unit. • Proper installation pr ocedures must be followed if this unit is being initially installed, or is moved to a new location after being in service. An INST ALLA TION GUIDE for your unit, providing complet[...]

  • Page 5

    ADA24 3 ADA SERIES Origins Refrigerator ADA24R, ADA24RGL • Features an ele ctronic cont rol panel with di gital displa y that allows you to display the interi or temperature and adjust the setting to your preference. The electronic control and di gital displa y provide an attracti ve appearance and its method of control permits precise temperatur[...]

  • Page 6

    4 ADA24 ADA SERIES Interior Lighting The interior of the cabinet can be illuminated w henever the door is opene d or remained darke ned for a 36-hour period (blacko ut/Sabbath mode [not Star K cert ified]). Figure 3 The LIGHT button (Figure 3, 1) on the control panel is used to change the lighting function s. T o turn the lights and disp lay OFF fo[...]

  • Page 7

    ADA24 5 ADA SERIES Checking Product T emperature Figure 5 IMPORT ANT IMPORT ANT U-Line re commends a set te mperat ure of 38°F on all refr igerators. T o check the actual produc t temperature in your unit, insert an accurate thermo meter into a pla stic (non- breakable) bottle that is pa rtially filled with water . T ighten the bottle cap securely[...]

  • Page 8

    6 ADA24 ADA SERIES Normal Operating Sounds All models incorporate rigid foam insulated cabinets to provide high thermal effi ciency and maximum sound reduction for its internal work ing components. In spite of this technolo gy , your mode l may make sounds that are unfamiliar . Normal operating sounds may be more noticeable because of the unit’ s[...]

  • Page 9

    ADA24 7 ADA SERIES General Cleaning Exterior Cleaning (As Require d) Vinyl C lad (Black or White) Models: • Surfaces may be cleaned with a mild detergent and warm water solution. Do no t use solvent-based or abrasive cleaners. Use a so ft sponge and rinse with clean water . Wipe with a so ft, c lean towel to prevent water spotting. • Clean any [...]

  • Page 10

    8 ADA24 ADA SERIES Defr osting Automatic (Cycle) Defr ost Models Automatic defrost models do not produce frost in normal operating conditions. Howeve r , a fr ost pattern may be noticed on the interio r walls if the unit is repeatedly opened in a high heat or high humidity location. If this frost pattern does not clear with in 24 hours, your unit w[...]

  • Page 11

    ADA24 9 ADA SERIES Wire Shelf Re moval/Installation Reposition the shel ves as follows: Figure 10 1. Remove shelf retention clip. 2. Pull s helf ou t about 6" (Figure 10, 1) , until back of shelf clears the “hump” on the right-hand side. 3. Tilt up right-hand edge of sh elf (Figure 10, 2) . 4. Remove shelf from unit by pulling out (Figure [...]

  • Page 12

    10 ADA24 ADA SERIES Door Alignment Check and Adjustment IMPORT ANT IMPORT ANT Properly aligned, the door’ s gasket should be firmly in contact with the cabinet all the way ar ound the door (no gaps). Carefully examine the door’ s gasket to assure that it is firmly in contact with the cabinet. Also make sure the door gasket is not pinched on the[...]

  • Page 13

    ADA24 11 ADA SERIES Figure 15 5. Remove pivot screw from top hinge, invert screw and reinstall pivot screw in top hinge (Figure 15) . Do not install hinge on cabinet at this time. Figure 16 6. Remove bottom hinge from cabinet (four scre ws) and screws on opposit e side of cabinet (Figure 16) . 7. Remove pivot screw from bottom hinge, invert screw a[...]

  • Page 14

    12 ADA24 ADA SERIES Before Calling for Service If your U-Line product appears to be ma lfunctioning, read through the OPERA TION section of this g uide to ensure th at the function of all controls are clearly understood. If th e malfunction persists, the TROU BLESHOOTING GUIDE in this guide will assist you in quickly identi fying c ommon problems, [...]

  • Page 15

    ADA24 13 ADA SERIES T r oubleshooting Guide DANGER ELECTROCUTION HAZARD Never attempt to repa ir or perfor m mai ntenance on the unit until the main electrical power has been disconnected. NOTE: Recommended te mperature setting is 38°. T roubleshooting - What to check when problems occur: PROBLEM POSSIBLE CAU SE REMEDY Unit does not operate a nd e[...]

  • Page 16

    14 ADA24 ADA SERIES T roubleshooting - Models with an electronic display: PROBLEM POSSIBLE CAU SE REMEDY Electronic display is blank an d interior light is off with door open. Unit is in blackout/Sabbath mode (not Star K certified). Exit blackout/Sabbath mode (not Star K certified) (See OPERA TION). Electronic display is blank an d interior light i[...]

  • Page 17

    ADA24 15 ADA SERIES Electronic Contr ol Quick Guide NOTE: 38°F is an example; the disp lay will vary with actual set-point. IMPORT ANT Factory recommended set-point is 38°F for r efrigerat ors and beverage centers, and 50°F for wine coolers. T ask T ouch T ouch Display Comment T urn ON/OFF Hold 10 seconds Release when °F flashes. or Adjust T em[...]

  • Page 18

    16 ADA24 ADA SERIES[...]

  • Page 19

    ADA SERIES U-Line Corporation Limited W arranty 1. U-Line Corporation ("U- Line") warrants each U-Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase. U-Line further wa rrants the sealed system (consisti ng of the com pressor , the cond enser , the evaporator , the hot gas b[...]

  • Page 20

    For General Inquiries: P .O. Box 245040 Milwaukee, Wisconsin 53224-9540 U.S.A. Phone (800) 779-2547 F AX (414) 354-5696 www .U-Line.com For Service and Parts Assistance: Phone (800) 779-2547 (414) 354-0300 F AX (414) 354-5696 Email: OnLineService@U-Line.com www .U-LineService.com E-mail: OnlineParts@u-line.com For more than four decades, U-Line has[...]