Go to page of
Similar user manuals
-
Automobile Alarm
Ultra Start 450 SERIES
12 pages 0.55 mb -
Automobile Alarm
Ultra Start 660 Series
16 pages 1.74 mb -
Automobile Alarm
Ultra Start 441
12 pages 1.85 mb -
Automobile Alarm
Ultra Start 3271M
20 pages 4.93 mb -
Automobile Alarm
Ultra Start 80 Series
24 pages 3.91 mb -
Automobile Alarm
Ultra Start 430 Series
12 pages 1.04 mb -
Automobile Alarm
Ultra Start 2250M
16 pages 1.57 mb -
Automobile Alarm
Ultra Start CJ series
12 pages 1.85 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Ultra Start KEU-300 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ultra Start KEU-300 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Ultra Start KEU-300 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Ultra Start KEU-300 Series should contain:
- informations concerning technical data of Ultra Start KEU-300 Series
- name of the manufacturer and a year of construction of the Ultra Start KEU-300 Series item
- rules of operation, control and maintenance of the Ultra Start KEU-300 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ultra Start KEU-300 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ultra Start KEU-300 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ultra Start service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ultra Start KEU-300 Series.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Ultra Start KEU-300 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
FCC/ID Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the [...]
-
Page 2
St atus LED/ Program Switch Shock Sensor Sensitivity Brown St arter Disable Relay St arter Disable Relay Ground When Armed See Page 3. See Page 5. See Page 5. See Page 3. See Page 3. See Page 3. See Page 4. See Page 4. See Page 3. See Page 3. See Page 3. See Page 4. See Page 4. See Page 4. See Page 4. See Page 4. See Page 4. Ignition Input Ground I[...]
-
Page 3
12 pin Main Harness Red - +12volt Power Source Input. Connect this wire to a +12 VDC constant power source. T o Battery or Ignition Harness. Black - System Ground Input. Connect this wire to chassis ground. T o a clean unpainted metal surface. Y ellow - Switched ignition input. Connect to switched ignition, 12VDC when the key is in the On, S tart a[...]
-
Page 4
12 Pin Connector ....Continued Purple- Positive Door Pin Input. Connect this wire to vehicles that have a door pin that switches to 12 volts when the door is opened. Green- Negative Door Pin Input. Connect this wire to vehicles that have a door pin that switches to Negative when the door is opened. Blue- Negative Hood/ T runk Input. Connect this wi[...]
-
Page 5
3 Pin Connector Continued Y ellow- Unlock Switch Sense Input Mode. This input is designed to prevent the switch from disarming the alarm system. Connect this wire to the Unlock wire that is activated with the unlock switch in the door but not by the factory remote. Some vehicles will have activation of its unlock wire from both the unlock switch an[...]
-
Page 6
DIP Switch Settings The DIP switches on the module are used to turn programmable features ON and OFF . The following are the features that are controlled by the DIP switches. Switch #1 ON= Passive Arming OFF= Active Arming In Passive Arming Mode the alarm will automatically arm 30 seconds after the last door is closed (Door pin connection required)[...]
-
Page 7
System Programming The following features are programmed using the ignition switch and the LED/ Program Switch. T o Enter Program Mode 1) T urn the ignition key “ON/OFF”, “ON/OFF” “ON” Leaving the key in the ON position. 2) Press and release the LED/ V alet Switch One time. The system will respond with one park light flash and on Siren/[...]
-
Page 8
Setting #3- Park Light Output T urn the ignition key “ON/OFF”, “ON/OFF” “ON”, press and release the program switch 3 times. The LED will flash Three times to confirm setting Three. Hold the program switch until the siren chirps the appropriate number of times. 1 Chirp 30 Second The park light s will stay ON for 30 seconds when the syste[...]