The rules should oblige the seller to give the purchaser an operating instrucion of UltraViolet Devices MP16A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of UltraViolet Devices MP16A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of UltraViolet Devices MP16A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of UltraViolet Devices MP16A should contain:
- informations concerning technical data of UltraViolet Devices MP16A
- name of the manufacturer and a year of construction of the UltraViolet Devices MP16A item
- rules of operation, control and maintenance of the UltraViolet Devices MP16A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of UltraViolet Devices MP16A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of UltraViolet Devices MP16A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the UltraViolet Devices service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of UltraViolet Devices MP16A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the UltraViolet Devices MP16A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
375 Marcus Boulevard • Hauppauge, NY 1 1 788 • USA 63 1 .273.0500 • Fax: 63 1 .273.077 1 e-mail: info@ultraviolet.com Extensive Product Information A vailable at: Document No. 98 - 1 123E1 • Revised February 2007 • © 1994-2007 Atlantic Ultraviolet Corporation www .ultraviolet.com[...]
-
Page 2
2 T ABLE OF CONTENTS S AFETY W ARNINGS .....................................................................................................................................................3 SAFETY INSTRUCTIONS ............................................................................................................................................[...]
-
Page 3
3 SAFETY W ARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property . This[...]
-
Page 4
4 PRODUCT APPLICA TION C ONSTRUCTION • The water purifier is designed to mount horizontally . • A drain port on the chamber aids in draining of the purifier . • The water purifier chamber is passivated and electropolished type 316 Stainless S teel. • The ballast housing is a combination of Stainless S teel T ype 304 and Aluminum Alloy . •[...]
-
Page 5
5 INST ALLA TION L OCA TION 1. The water purifier is intended for indoor use only . The water purifier should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier , should be between 33 F and 100 F. 2. Electrical power supplied to the water purifier MUST mat[...]
-
Page 6
6 6 3. The water purifier should be mounted horizontally on a flat dry surface. Secure the water purifier using the mounting holes in the ballast housing or with the optional wall mounting kit. The purifier should not be solely supported by its plumbing connections. 4. The water purifier must be connected to the cold water line only . 5. It is reco[...]
-
Page 7
7 R ECOMMENDED O PTIONS 1 . Guardian ™ Ultraviolet Monitor: V isually indicates the level of germicidal ultraviolet energy that penetrates the quartz sleeve and the water within the water purifier . The ultraviolet monitor is capable of operating an optional audio alarm and/or solenoid valve. The ultraviolet monitor will detect reduction of ultra[...]
-
Page 8
8 MAINTENANCE The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels, see “ W ater Quality ” in the “ Pr oduct Application ” section. Ordinary mainte- nance consists of; • Lamp replacement is recommended every 10,000 hours of operation, appro[...]
-
Page 9
9 S tep 2 - Remove End-Cap S tep 3 - W ithdraw Lamp S tep 4 & 5 - Remove Sockets S tep 6 - Remove Lamp L AMP I NST ALLA TION OR R EPLACEMENT Figure 3 - Lamp Replacement 1. Disconnect power to water purifier . 2. Remove both easy-off end caps by pulling each cap of f static gland nut. Slide each end cap along the wire away from the socket. 3. Ca[...]
-
Page 10
10 1. Disconnect power to water purifier . 2. Shut off water supply to water purifier via inlet and outlet shut of f valves. Drain chamber by removing drain plug. Once the chamber is completely drained, remove any old sealing tape from the threads of the drain plug, rewrap with 1/2" wide T eflon ® thread sealing tape, reinstall and tighten th[...]
-
Page 11
11 R EPLACEMENT OF B ROKEN Q UARTZ S LEEVE CAUTION: Broken Quartz is SHARP . It is r ecommended that protective goggles and gloves are worn when handling br oken quartz sleeves. 1. Disconnect power to water purifier . 2. Shut off water supply to the water purifier via the inlet and outlet shut of f valves. Drain the chamber by removing the drain pl[...]
-
Page 12
12 O PTIONAL G UARDIAN ™ ™ U L TRA VIOLET M ONIT OR S ENSOR P ROBE C LEANING Figure 5 - Ultraviolet Monitor and Sensor Probe If after cleaning the quartz sleeve, there is no significant improvement in the ultraviolet intensity , as shown on the intensity meter , it may be necessary to clean the Ultraviolet Monitor's sensor probe. The senso[...]
-
Page 13
13 Problem Possible Cause Corrective Action No electrical power… V erify that the purifier is connected to a live power source. Ballast Disconnect the purifier from utility power . Replace lamp. Lamp-out Protection The purifier must remain disconnected from power for (MP16A, MP22A & MP36C) two (2) minutes to reset. Cracked or broken Shut down[...]
-
Page 14
14 TECHNICAL SPECIFICA TIONS T able 4 - T echnical Specifications Model: MP13A MP16A MP22A MP36C MP49C Flow Rate (GPM): 2 3 6 12 20 InletOutlet Size: 1 / 2 " m NPT 3 / 4 " m NPT 3 / 4 " m NPT 1 " m NPT 1- 1 / 2 " m NPT Number of Lamps: 1 1 1 1 1 Lamp Model No.: GPH212T5L GPH287T5L GPH436T5L G36T6L G48T6L Length: 13- 1 / 2 [...]
-
Page 15
15 OPTIONAL ACCESSORIES Optional accessories are available for operation at 120v 60Hz or 220v 50Hz, unless specified. Please specify . Consult Factory for 12v DC or other special input power requirements. T able 5 - Optional Accessories Optional Accessories Available for: Guardian ™ Ultraviolet Monitor - Analog / Digital MP13A through MP49C Sentr[...]
-
Page 16
16 REPLACEMENT P AR TS Mighty Pure ™ ™ Models MP13A, MP16A & MP22A Figure 6 - Exploded V iew MP13A, MP16A & MP22A[...]
-
Page 17
17 ITEM MP13A MP16A MP22A NO. DESCRIPTION QTY P AR T NO. QTY P AR T NO. QTY P AR T NO. 1 Easy-Off End Cap 2 25-1499A1 2 25-1499A1 2 25-1499A1 2 Rubber O-ring, Static Gland 2 00-1 108B 2 00-1108B 2 00-1108B 3 Lamp Spacer 2 25-0208A 2 25-0208A 2 25-0208A 4 Lead W ire & Socket 2 05-1219B2 2 05-1219B2 2 05-1219B3 5 Lamp 1 05-1400 1 05-1098 1 05-109[...]
-
Page 18
18 REPLACEMENT P AR TS Mighty Pure ™ ™ Models MP36C & MP49C Figure 7 - Exploded V iew MP36C & MP49C[...]
-
Page 19
19 ITEM MP36C MP49C NO. DESCRIPTION QTY P AR T NO. QTY P AR T NO. 1 Easy-Off End Cap 2 25-1499A1 2 25-1499A1 2 Rubber O-ring, Static Gland 2 00-1108B 2 00-1 108B 3 Lamp Spacer - - 2 25-0209A 4 Lead W ire & Socket 2 05-1218A2 2 05-1218A2 5 Lamp 1 05-1343 1 05-1334 6 Static Gland Nut 2 25-1492D 2 25-1492D 7 T eflon ®[...]
-
Page 20
20 W ARRANTY W e warrant that this product will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product’ s total rated life, whichever first occurs. W ithin the warranty period we shall repair or replace such products, which are returned to us with shipping charges prepaid, and wh[...]