Go to page of
Similar user manuals
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of United States Stove 1602M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of United States Stove 1602M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of United States Stove 1602M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of United States Stove 1602M should contain:
- informations concerning technical data of United States Stove 1602M
- name of the manufacturer and a year of construction of the United States Stove 1602M item
- rules of operation, control and maintenance of the United States Stove 1602M item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of United States Stove 1602M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of United States Stove 1602M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the United States Stove service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of United States Stove 1602M.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the United States Stove 1602M item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 USSC 851767 rev 0 Model: 1602M Wood or Coal Gravity Style (Up-Flow) Supplemental Fur na ce C O M P A N Y U N I T E D S T A T E S S T O V E C S S U United States Stove Company • 227 Industrial Park Road, P.O. Box 151 • South Pittsburg, TN 37380 • www.usstove.com SAFETY NOTICE: If this furnace is not properly installed, a house re may resu[...]
-
Page 2
2 USSC INTRODUCTION Thank You for your purchase of a U.S. Stove Wood/Coal Burning Gravity Style (Up-Flow) Furnace. Your decision to buy our Clayton Furnace was undoubtedly reached af - ter much careful thought and consideration. We are very proud you chose this furnace and trust you will receive the comfort and economy that others realize when heat[...]
-
Page 3
3 USSC CHIMNEY REQUIREMENTS A reclay lined masonry or Class A 103HT All-Fuel Metal Insulated Chimney must be used in all airtight wood fur - nace installations. The minimum recommended ue size for the model 1602 is 6 inches, inside diameter. When mak - ing new chimney installations, always follow the chimney manufacturer’s instructions. If [...]
-
Page 4
4 USSC DAMPERS ON STOVE PIPES When burning coal, we recommend a Barometric Draft Damper be installed at a safe convenient place between chimney and your furnace preferably less than 3’ from the ue collar. When you have installed the connector pipe between your furnace and the chimney, tap the pipe hard with your ngernail. Remember the sound[...]
-
Page 5
5 USSC INSTALLATION #3 The bafe on this system should be made the full width of the furnace plenum in order to properly direct the air into the distribution ducts. INSTALLATION #2 Exte nding the hot air duct fro m the furn ace into the existing plenum will help direct the ow of air from the furnace as well as the ow in the existing furnace[...]
-
Page 6
6 USSC FURNACE ASSEMBL Y INSTRUCTIONS Unpack your Furnace and insure that there is no shipping damage. If damage exist, please contact your dealer im - mediately. Your Clayton Furnace will require some assembly before operation. All needed hardware and components for the following assemblies are included within the parts boxes inside the furnace an[...]
-
Page 7
7 USSC SPRING HANDLES Attach the four(4) spring handles to the Feed/Ash Doors, Bafe Rod, and Shaker Rod by twisting the springs counter- clockwise while applying pressure until you have screwed them approximately 3/4”-1” onto the rods. (4) Spring Handles DISTRIBUTION BLOWER & ACC. (2) 800 CFM Blower (2) Gasket, Blower (8) Tinnerman Clip,[...]
-
Page 8
8 USSC FIREBOX BRICK REPL ACEMENT This furnace comes from the factory with the rebrick in - stalled. However, if brick replacement is necessary, follow these instructions. Before furnace operation, remove the brick retaining strip. This piece is used during shipping to reduce brick damage. There are 6 full brick and 1 half brick per side . Insta[...]
-
Page 9
9 USSC When you start a re in the furnace and it reaches op - erating temperature, the blower(s) will come on auto - matically. The snap-disc is adjustable from 100°F(A) to 140°F(E), Each click on the switch is approximately 5°F. It comes from the factory, set at 120°F, setting C. The rocker switch on the top of the junction box gives you th[...]
-
Page 10
10 USSC Do not over draft the furnace! It is designed to operate at .06 inches of water column and must be set with a draft gauge to maintain a steady draft. (Barometric Damper recommended.) Do not allow ashes to build up higher than 2” above grates. Never allow the ashes in the ash pan touch the grate section. REMOVE A[...]
-
Page 11
11 USSC TROUBLE SHOOTING AND PROBLEM SOL VING 1. Problem: Smoke puffs from furnace Solution: A. Check chimney draft. Check for blocked chimney or ue pipe. Use mirror to check chimney clearance. B. Check ash pit — if it is too full, empty. C. Make sure furnace room is not too airtight. D. Make sure all of chimney mortar connections are airtight[...]
-
Page 12
12 USSC P ARTS DIAGRAM 1 1 12 13 16 15 17 14 7 10 5 2 3 6 30 29 4 3 2 1 35 3 8 9 24 26 25 27 17 16 3 19 18 20 28 34 21 22 32 33 23 31[...]
-
Page 13
13 USSC P ARTS DIAGRAM AND LIST 38 45 44 46 48 40 37 36 39 41 42 43 47 49 IMPORTANT NOTE: When ordering repair parts, a color code (G) should be placed after the part number of any part that is painted. Key Description Part # Qty 1 Feed Door Assy. (w/Rope Gasket) 69091 1 2 Door Handle 24179 2 N/S Lock Nut, 1/2-13 83444 2 N/S Washer 83835 2 3 Spring[...]
-
Page 14
14 USSC 16DIKL FORCED DRAFT BLOWER - OPTIONAL KIT 1 4 3 5 2 Key Description Part # Qty 1 Drqft Blower Assembly 69190 1 2 FAD Bracket 69192 1 3 Bolt, 1/4-20 x 1” 83379 2 4 Lock Nut, 1/4-20 83261 2 5 Kep Nut, 10-24 83244 3 6 Honeywell Limit Control 80145 1 7 Fan Center 80130 1 8 Thermostat 80129 1 UFB908 COLD AIR RETURN / FIL TER BOX - OPTIONAL KIT[...]
-
Page 15
15 USSC DOMESTIC HOT WA TER COIL - OPTIONAL KIT DOMESTIC HOT W A TER COIL REAR W ALL OF FIREBOX TURN INSIDE NUTS UP TO END OF THREADS 1. NUT 2. W ASHER 3. GASKET 2 3 4 5 6 ACCESS P ANEL 1 This Furnace will accept the installation of a Domestic Hot Water Coil Kit. The U.S. Stove kit is a 1124 Water Coil and it may be purchased from your local dealer[...]
-
Page 16
16 USSC BULLETIN RC454 A GUIDE TO BURNING COAL IN YOUR FURNACE Furnaces that are capable of burning coal usually will burn both Bituminous and Anthracite coal. An - thracite is perhaps the best coal fuel because of its long even burn time, high heat output, and cleanli - ness which make it a good choice for the home. However, keep in mind it is a m[...]
-
Page 17
17 USSC When the re is well established and the room is be - coming warm, partially close the dampers. Some experimenting will have to take place with each particular setting of all dampers and controls as the chimney provides the draft necessary to not only exhaust the smoke, but to pull combustion air into the heater as well - and no two chimn[...]
-
Page 18
18 USSC NOTES[...]
-
Page 19
19 USSC NOTES[...]
-
Page 20
20 USSC HOW TO ORDER REP AIR P ARTS This manual will help you obtain efcient, dependable service from the fur - nace, and enable you to order repair parts correctly. Keep this manual in a safe place for future reference. When placing an order or for warranty claims, please provide the following information found on the Certication Plate locat[...]