The rules should oblige the seller to give the purchaser an operating instrucion of Vanguard Heating SDVBP(A), along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vanguard Heating SDVBP(A) one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Vanguard Heating SDVBP(A). A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Vanguard Heating SDVBP(A) should contain:
- informations concerning technical data of Vanguard Heating SDVBP(A)
- name of the manufacturer and a year of construction of the Vanguard Heating SDVBP(A) item
- rules of operation, control and maintenance of the Vanguard Heating SDVBP(A) item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vanguard Heating SDVBP(A) alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vanguard Heating SDVBP(A), and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vanguard Heating service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vanguard Heating SDVBP(A).
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Vanguard Heating SDVBP(A) item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
CAST IRON STOVE AND DIRECT -VENT (FREEST ANDING FIREPLACE HEA TER) BURNER SYSTEM ® OWNER’S OPERA TION AND INST ALLA TION MANUAL NA TURAL GAS BURNER SYSTEM MODEL SDVBN(A) PROP ANE/LP GAS BURNER SYSTEM MODEL SDVBP(A) REMOTE READY Save this manual for future reference. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any applianc[...]
-
Page 2
2 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP burner system, do not place propane/LP supply tank(s) inside any st[...]
-
Page 3
3 105499 OWNER’S MANUAL P I L O T L O H I OFF ON ON OFF AUTO PRODUCT IDENTIFICA TION Install and use stove and burner system with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1 , also known as NFPA 54* (USA) or the current CAN/CGA- B149[.1 or .2] Installation Codes (Canada) . *Availa[...]
-
Page 4
4 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your Vanguard cast iron stove. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning [...]
-
Page 5
5 105499 OWNER’S MANUAL Pallet Wood Bolted to Bottom of Stove Body STOVE BODY ASSEMBLY 1. Lift off corrugated box enclosing stove body crating. 2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body . The bottom pieces of pallet wood will remain bolted to the stove body . 3. Re[...]
-
Page 6
6 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) CAST IRON STOVE AND DIRECT -VENT BURNER SYSTEM ASSEMBL Y Continued Figure 12 - Attaching Stove Door Step Bolt Door Hinge Threaded Hole Stove Door Stove Bottom Bolt Shoulder Adjusting Nut Bolt Stop Catch Bolt Door Claw Door Figure 13 - Catch Bolt and Door Claw Orientation 10. Attach[...]
-
Page 7
7 105499 OWNER’S MANUAL WARNING: Never touch the blower wheel while in operation. 7. Peel off the backing paper and stick the supplied wiring diagram decal on the inside of rear cover on right side oppo- site control. WARNING: Failure to position the parts in accordance with sup- plied diagrams or failure to use only parts specifically approved w[...]
-
Page 8
8 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) LOCATION OF VENT TERMINATION When locating vent termination, it is impor- tant to observe the minimum clearances shown in Figure 18, page 9. *Check with local codes or with the current CAN/CGA B149[.1 or .2] Installation Codes for Canada or the USA Installations follow the current [...]
-
Page 9
9 105499 OWNER’S MANUAL Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (305mm) minimum] B = clearance to window or d[...]
-
Page 10
10 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of im- properly installed and maintained venting system could result in serious injury, property d[...]
-
Page 11
11 105499 OWNER’S MANUAL INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed. Snorkel terminations are available for terminations requ[...]
-
Page 12
12 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) UP VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1 / 2 " (190mm) V ent Opening Combustible W all V ent Opening Noncombustible W all Figure 22 - Vent Opening Requirements 3. Attach vent pipe assembly to the burner system. Set stove in fr[...]
-
Page 13
13 105499 OWNER’S MANUAL VENTING INST ALLA TION Continued Figure 26 - Horizontal Termination Configuration for Rigid Venting Figure 27 - Horizontal Termination Configuration for Rigid Venting Using One 90 ° Elbow Horizontal V enting V ertical (V) Horizontal (H) 37" min. 29" max. (30 ° and 90 ° only , no vertical pipe) 48" min. 4[...]
-
Page 14
14 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) Flat Ceiling Installation 1. Cut a 10" square hole in the ceiling us- ing the locating hole as a center point. The opening should be framed to 10"x10" (254mm x 254mm) inside di- mensions, as shown in Figure 22 on page 12 using framing lumber the same size as the cei[...]
-
Page 15
15 105499 OWNER’S MANUAL VENTING INST ALLA TION Continued Figure 31 - Installing Firestop If area above is not a room, install firestop below framed hole. If area above is a room, install firestop above framed hole. Continued 3. Cut a hole in the roof using the locating hole as a center point. (Cover any ex- posed open vent pipes before cutting h[...]
-
Page 16
16 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) V enting with T wo 9 0 ° Elbo ws V ertical (V 1 ) Horizontal (H) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. Note: V ertical (V 1 ) + V ertical (V 2 ) = 20' max. Figure 36 - Vertical Rigid Venting Configuration U[...]
-
Page 17
17 105499 OWNER’S MANUAL Figure 37 - Vertical Rigid Venting Configuration With No Horizontal Run VENTING INST ALLA TION Continued V er tical V enting V = 40' max. RVKBK Kit Shown Note: Install restrictor into 4" collar of burner system as shown. HIGH ALTITUDE INSTALLATION Your Vanguard cast iron stove and direct- vent burner system has [...]
-
Page 18
18 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) Figure 39 - Gas Connection * The A.G.A. design-certified manual shutoff valve may be supplied with the appliance or you can purchase it from your dealer. CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your loc[...]
-
Page 19
19 105499 OWNER’S MANUAL Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect burner system and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage burner system gas regulator . 2. Cap of f open end of gas pipe where manual shuto[...]
-
Page 20
20 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) STOVE AND DIRECT -VENT BURNER SYSTEM INST ALLA TION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close manual shutoff valve (see Fig- ure 41). 2. Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas burner sys-[...]
-
Page 21
21 105499 OWNER’S MANUAL STOVE AND DIRECT -VENT BURNER SYSTEM INST ALLA TION Continued INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1 WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures. WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard wi[...]
-
Page 22
22 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this burner system with a broken glass door panel or without the glass door panel securely in place. For replacement part in- formation see Replacement Parts , page 31. 1. Remove 2 bolts from bottom of stove and one from the to[...]
-
Page 23
23 105499 OWNER’S MANUAL Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with freestanding burner system. Do not use if any log(s) are broken (see Replacement Parts , page 31). 1. Remove glas[...]
-
Page 24
24 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) TO TURN OFF GAS TO APPLIANCE 1. Open lower louver panel. 2a. T urn ON/OFF switch to “OFF”. 2b . If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to pre vent draining battery . 3. T urn off all electrical power to the appliance if service is to be p[...]
-
Page 25
25 105499 OWNER’S MANUAL 1. After lighting, let pilot flame bur n f or about one minute. T urn ga s control knob on the control v alve to ON posi- tion. T urn va ri ab le control knob any- where between HI and LO. Slide the selector switch to the REMO TE posi- tion. Note: The bur ners may light if hand-held remote ON b utton was on when selector [...]
-
Page 26
26 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if neces[...]
-
Page 27
27 105499 OWNER’S MANUAL CLEANING AND MAINTENANCE WARNING: Turn off burner system and let cool before cleaning. CAUTION: You must keep control areas, burners, and cir- culating air passageways of burner system and stove clean. Inspect these areas of burner system and stove before each use. Have burner system and stove inspected yearly by a quali-[...]
-
Page 28
28 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off burner system and let cool before ser- vicing. Only a qualified service person should service and repair burner system or stove. CAUTION: Never use a wire, needle, or similar object[...]
-
Page 29
29 105499 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Burner system produces a whistling noise when burner is lit Glass soots Burner system produces a clicking/ticking noise just after burners are lit or shut off [...]
-
Page 30
30 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppl[...]
-
Page 31
31 105499 OWNER’S MANUAL SER VICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • burner system will not produce speci- fied heat • propane/LP gas supply might be low (propane/LP units only) When Gas Quality Is Bad • pilot will not stay lit • burners will produce flames and soot • [...]
-
Page 32
32 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) SPECIFICA TIONS SDVBN(A) SDVBP(A) 16,000-22,000 Btu/h 14,000-20,000 Btu/h Gas Type Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c. Thermal Efficiency 70% 70% Dimension, Inches/mm [...]
-
Page 33
33 105499 OWNER’S MANUAL ACCESSORIES Purchase these stove and burner system accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800- 432-2382. for information. You can also write to the address listed on the back page of this manual. WALL MOUNTED THERMOSTAT CONTROL KIT GW[...]
-
Page 34
34 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) ILLUSTRA TED PA R T S BREAKDOWN SDVBN(A) SDVBP(A) L O H I P I L O T OFF ON 24 27 19 20 21 23 26-1 26-4 26-2 26-3 29 30 4 25 1 2 4 4 7 8 9 10 11 13 12 31 15 16 17 18 22 22 28 5 32 3 14 6[...]
-
Page 35
35 105499 OWNER’S MANUAL KEY NO. PART NUMBER DESCRIPTION QTY. 1 105478-01BR Firebox Assembly 1 2 M11084-26 Screw, Hex 2 3 105482-01CK Rear Cover 1 4 M11084-39 Screw, Hex 12 5 103587-02CK Switch Plate 1 6 099998-01 On/Off Switch 1 7 103284-04 Wire Harness 1 8 104491-01 Relief Cover 1 9 104518-01 Relief Cover Gasket 1 10 104527-01 Relief Spring 2 1[...]
-
Page 36
36 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) ILLUSTRA TED PA R T S BREAKDOWN AMITY™ SCIVF(*) SERIES PSCIVF(*) SERIES (* Indicates Color Suffix Designation) 1 2 5 8 7-4 6 5 5 7-1 7-2 5 4 7-3 3 AMITY ™ STOVE CHASSIS[...]
-
Page 37
37 105499 OWNER’S MANUAL P ARTS LIST AMITY™ SCIVF(*) SERIES PSCIVF(*) SERIES (* Indicates Color Suffix Designation) This list contains replaceable parts used in your stove. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. * Included In Hardware Kit KEY PART NO. NO. DESCRIPTION QTY. 1 104171-[...]
-
Page 38
VANGUARD LIMITED WARRANTY DIRECT-VENT BURNER SYSTEM AND AMITY ™ STOVE CHASSIS DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions[...]