Vanguard Heating VP1600ITA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Vanguard Heating VP1600ITA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vanguard Heating VP1600ITA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Vanguard Heating VP1600ITA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Vanguard Heating VP1600ITA should contain:
- informations concerning technical data of Vanguard Heating VP1600ITA
- name of the manufacturer and a year of construction of the Vanguard Heating VP1600ITA item
- rules of operation, control and maintenance of the Vanguard Heating VP1600ITA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vanguard Heating VP1600ITA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vanguard Heating VP1600ITA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vanguard Heating service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vanguard Heating VP1600ITA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Vanguard Heating VP1600ITA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Save this manual for future reference. Models: VP1600D, VP1600IT A, VP2600D, and VP2200IT A ® INFRARED VENT -FREE PROP ANE/LP GAS HEA TER This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer OW[...]

  • Page 2

    2 101823 CONTENTS SECTION PAGE Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ................................................................................... 4 Unpacking ......................[...]

  • Page 3

    3 101823 SAFETY INFORMA TION Continued WARNING ICON G 001 W ARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any stru[...]

  • Page 4

    4 101823 PRODUCT FEA TURES Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. Piezo Ignition System This heater has a piezo ignitor. This system requires no matches, batteries,[...]

  • Page 5

    5 101823 FRESH AIR FOR COMBUSTION AND VENTILA TION WARNING ICON G 001 W ARNING This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. Today’s homes are buil[...]

  • Page 6

    6 101823 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or[...]

  • Page 7

    7 101823 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 WARNING ICON G 001 W ARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space,[...]

  • Page 8

    8 101823 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued Figure 3 - Ventilation Air from Outdoors Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outd[...]

  • Page 9

    9 101823 INST ALLING T O W ALL NOTICE A qualified service person must install heater. Follow all local codes. Continued CHECK GAS TYPE Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION ITEMS Before installing heater, make sure you have the i[...]

  • Page 10

    10 101823 For convenience and efficiency, install heater • where there is easy access for operation, inspection, and service • in coldest part of room An optional fan kit is available from your dealer. See Accessories , page 31 If planning to use fan, locate heater near an electrical outlet. THERMOSTAT SENSING BULB (Models VP1600ITA and VP2200I[...]

  • Page 11

    11 101823 INSTALLING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel. INST ALLING T O W ALL Continued Mounting Bracket Figure 6 - Mounting Bracket Location Removing Front Panel Of Heater 1. Remove two screws near bottom corners of [...]

  • Page 12

    12 101823 Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mount- ing bracket is level. 2. Mark screw locations on wall (see Figure 8). Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall. Models VP26[...]

  • Page 13

    13 101823 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. Figure 10 - Popping Open Anchor Wings For Thin Walls 5. Place mounting bracket onto wall. Line up last hole on each[...]

  • Page 14

    14 101823 CONNECTING T O GAS SUPPL Y NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. Typical Pipe Diameters VP1600D or VP1600ITA 3/8" or greater VP2600D or VP2200ITA 1/2" or greater Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within rea[...]

  • Page 15

    15 101823 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. Tee Joint Reducer Bushing to 1/8" NPT 1/8" NPT Plug Tap Test Gauge Connection * Sediment Trap Tee Joint Pipe Nipple Cap CHECKING GAS CONNECTIONS Manual Shutoff Valve * 1/2" NPT Pipe Nipple Ground Joint Union Heater Cabinet PRESS[...]

  • Page 16

    16 101823 3. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff v[...]

  • Page 17

    17 101823 OPERA TING HEA TER Models VP1600IT A and VP2200IT A FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier tha[...]

  • Page 18

    18 101823 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information at the top of page 17. 2. Make sure manual shutoff valve is fully open. 3. Turn thermostat control knob on left side of heater clockwise Clockwise to the OFF position. OPERA TING HEA TER Models VP1600IT A and VP2200IT A Continued 4. Wait five minutes to clear out any gas. Then sme[...]

  • Page 19

    19 101823 Figure 18 - Pilot OPERA TING HEA TER Models VP1600IT A and VP2200IT A Continued T O SELECT HEA TING LEVEL WARNING ICON G 001 CAUTION Do not try to adjust heating levels by using the manual shut- off valve. WARNING ICON G 001 W ARNING When running heater, set control knob at the 1, 2, 3, or 4 locked positions. Never set control knob betwee[...]

  • Page 20

    20 101823 T O TURN OFF GAS TO APPLIANCE OPERA TING HEA TER Models VP1600IT A and VP2200IT A Continued Shutting Off Heater 1. Turn thermostat control knob clockwise Clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit) 1. Turn thermostat control knob c[...]

  • Page 21

    21 101823 HIGH OFF LOW MED PILOT IGN IGNITOR OPERA TING HEA TER Models VP1600D and VP2600D FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor be[...]

  • Page 22

    22 101823 4. Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 21. If you don’t smell gas, go to the next step. 5. Press in control knob. Note: You may be running this heater for the first time after hooking up to gas supply. If[...]

  • Page 23

    23 101823 T O SELECT HEA TING LEVEL Figure 22 - Burner Patterns LOW HIGH OFF MED 1. Slightly press in control knob and turn counterclockwise C-clockwise to the LOW, MEDIUM, or HIGH positions. IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position. OPERA TING HEA TER Models VP1600D and VP2600D[...]

  • Page 24

    24 101823 GRH/OV 007 GOOD PILOT/LP Thermocouple Pilot Burner Figure 23 - Correct Pilot Flame Pattern Thermocouple GRH/OV 008 BAD PILOT/LP Pilot Burner Figure 24 - Incorrect Pilot Flame Pattern If pilot flame pattern is incorrect, as shown in Figure 24 • turn heater off (see To TurnOff Gas to Appliance , page 20 [models VP1600ITA and VP2200ITA] or[...]

  • Page 25

    25 101823 Figure 25 - Correct Burner Flame Pattern Bad Burner Pattern-Plaque GRH/OV 019 Figure 26 - Incorrect Burner Flame Pattern If burner flame pattern is incorrect, as shown in Figure 26 • turn heater off (see To Turn Off Gas to Appliance , page 20 [models VP1600ITA and VP2200ITA] or page 24 [models VP1600D and VP2600D]) • see Troubleshooti[...]

  • Page 26

    26 101823 CLEANING AND MAINTENANCE WARNING ICON G 001 W ARNING Turn off heater and let cool before cleaning. WARNING ICON G 001 CAUTION You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more [...]

  • Page 27

    27 101823 REMEDY 1. Turn on gas supply or open manual shutoff valve. 2. Press in control knob while pressing ignitor button (non-thermostat models only). Press in thermostat control knob while turning to PILOT/IGN position (thermostat models only) 3. Continue holding down control knob. Repeat igniting operation until air is removed. 4. Contact loca[...]

  • Page 28

    28 101823 OBSERVED PROBLEM Burner(s) does not light after ODS/pilot is lit. Delayed ignition of burner(s) Burner backfiring during combustion. Burner plaque(s) does not glow. Slight smoke or odor during initial opera- tion Heater produces a clicking/ticking noise just after burner is lit or shut off. REMEDY 1. Clean burner orifice(s) (see Cleaning [...]

  • Page 29

    29 101823 WARNING ICON G 001 W ARNING TROUBLE- SHOOTING Continued If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you canno[...]

  • Page 30

    30 101823 SPECIFICA TIONS VP1600ITA VP2200ITA Btu (Variable) 6,000-16,000 6,500-22,000 Type Gas Propane/LP Only Propane/LP Only Ignition Piezo Piezo Pressure Regulator Setting 8" W.C. 8" W.C. Inlet Gas Pressure (in. of water) Maximum 14" 14" Minimum 11" 11" Dimensions, Inches (H x W x D) Heater 23.5 x 18.5 x 8 23.5 x 2[...]

  • Page 31

    31 101823 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. Parts Under Warranty Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call DESA International’s Technical Service Department a[...]

  • Page 32

    32 101823 HEATER EXPLODED VIEW ILLUSTRA TED P ARTS BREAKDOWN Model VP1600IT A 1 2 3 11 6 4 8 5 6 7 12 23 9 10 24 14 17 16 21 18 22 20 19 15 13 ODS/PILOT A B C 23-1 23-2 23-3 23-4 23-5 23-7 23-6 23-8 23-9 23-15 23-11 23-12 23-10 23-13 23-14 23-17 23-16 BURNER ASSEMBLY[...]

  • Page 33

    33 101823 P ARTS LIST Model VP1600IT A This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098742-13 Front Panel 1 3 098238-06 Grill Guard 1 4 101108-01 Clip-Grill G[...]

  • Page 34

    34 101823 1 2 3 11 6 4 8 5 6 7 12 23 9 10 24 14 17 16 21 18 22 20 19 15 13 ILLUSTRA TED P ARTS BREAKDOWN Model VP2200IT A 23-18 23-17 D C 23-1 23-2 23-3 23-8 23-13 23-12 23-11 B A 23-5 23-6 23-4 23-9 23-7 23-16 23-10 23-14 23-15 BURNER ASSEMBLY HEATER EXPLODED VIEW ODS/PILOT[...]

  • Page 35

    35 101823 P ARTS LIST Model VP2200IT A This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098742-14 Front Panel 1 3 098238-07 Grill Guard 1 4 101108-01 Clip-Grill G[...]

  • Page 36

    36 101823 HEATER EXPLODED VIEW ILLUSTRA TED P ARTS BREAKDOWN Model VP1600D 13-15 13-14 BURNER ASSEMBLY A B C 13-1 13-2 13-3 13-10 13-4 13-5 13-6 13-7 13-8 13-9 13-12 13-13 13-11 13-16 ODS/PILOT 1 2 3 11 6 4 8 5 6 7 12 18 13 9 10 14 16 15 17[...]

  • Page 37

    37 101823 P ARTS LIST Model VP1600D This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098742-13 Front Panel 1 3 098238-06 Grill Guard 1 4 101108-01 Clip-Grill Guar[...]

  • Page 38

    38 101823 HEATER EXPLODED VIEW ILLUSTRA TED P ARTS BREAKDOWN Model VP2600D 13-15 13-14 ODS/PILOT BURNER ASSEMBLY E D C 13-1 13-2 13-3 13-9 13-4 13-5 13-7 13-6 13-8 13-10 13-12 13-13 13-11 B A 13-16 1 2 3 11 6 13 4 8 5 6 7 12 18 9 10 14 15 16 17[...]

  • Page 39

    39 101823 P ARTS LIST Model VP2600D This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098742-14 Front Panel 1 3 098238-07 Grill Guard 1 4 101108-01 Clip-Grill Guar[...]

  • Page 40

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Model Serial No. Date Purchased 101823-01 REV. D 3/96 Patent Pending LIMITED WARRANTY VANGUARD VENT-FREE PROPANE/LP GAS HEATERS DESA International warrants this product to be free from defects in materials and components for three (3) years from the date of first purchase, provided that the product has been[...]