Vanguard FBST manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Vanguard FBST, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vanguard FBST one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Vanguard FBST. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Vanguard FBST should contain:
- informations concerning technical data of Vanguard FBST
- name of the manufacturer and a year of construction of the Vanguard FBST item
- rules of operation, control and maintenance of the Vanguard FBST item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vanguard FBST alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vanguard FBST, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vanguard service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vanguard FBST.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Vanguard FBST item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ® Sav e this manual for future reference. For more information, visit www .desatech.com UNVENTED (VENT -FREE) LogMate ® UNIVERSAL FIREBO X OWNER’S OPERA TION AND INST ALLA TION MANU AL MODEL FBST 36" See-Thru Heat-Circulating Firebox FOR YOUR SAFETY — Do not store or use gasoline or any other ammable v[...]

  • Page 2

    www .desatech.com 1051 16-01D 2 W ARNING: Improper installation, adjustment, altera - tion,service ormaintenancecan causeinjury orprop - erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a?[...]

  • Page 3

    www .desatech.com 1051 16-01D 3 SAFETY INFORMA TION IM PO RT ANT : R ea d t hi s o wn er’ s ma nu al c ar ef u ll ya nd c om pl et e ly b e f o r e  t r y i n g  t o  as se m b l e ,  op er a t e or  se rv ic eth is  r ebo x. Imp ro pe r us e of th is  re bo x ca nc au se [...]

  • Page 4

    www .desatech.com 1051 16-01D 4 12. Do not use th e reb ox if it has bee n unde r wat er due to the sho ck haz ard th at cou ld res ult wi th the blo wer acce ssar y ( if i nsta lled ) i n pl ace. 1 3 . Provide adequate clearances around air openings. LOCAL CODES Install and use rebox with care. Follow all local codes. In the absence of local[...]

  • Page 5

    www .desatech.com 1051 16-01D 5 LOCA TING FIREBO X PLANNING Plan where you will install the rebox. This will sav e time and mone y later whe n you instal l the re - box. Before installation, consider the following: 1. Where the rebox will be located. Allow for wall and ceiling clearances (see Installation Clearances , page 8). 2. Everythin[...]

  • Page 6

    www .desatech.com 1051 16-01D 6 Unusually tight construction is dened as con - struction where: a. walls and ceilings exposed to the outside atmospher e have a continuous water vapor retarder with a rating of one perm (6 x 10 - 1 1 kg per pa-sec-m 2 ) or less with openings gasketed or sealed and b. weather stripping has been added on open- able [...]

  • Page 7

    www .desatech.com 1051 16-01D 7 The space in the above example is a conned space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. Y ou must provid e additional fresh air. Y our option s are as follows: A. Rework work sheet, adding the space of an adjoining room. If the extra space provides an unconned spac[...]

  • Page 8

    www .desatech.com 1051 16-01D 8 INST ALLA TION NOTICE: This rebox in com - bination with unvented log sets are intended for use as supplemental heat. Use along with your primary heating  system. Do not install them as your primary heat source. If you have a central [...]

  • Page 9

    www .desatech.com 1051 16-01D 9 Figure 5 - Minimum Clearance - Front V iew 42" Min. 0" to Wood Floor 8" Min. 0" Min. Clearance to Upper Frame/Wallboard Ceiling 4" Min. from the Perpendicular Side Wall to the Edge of Facial 1/2" Min. Clearance to Combustibles 44 1 / 4 " 24" Figure 6 - Minimum Clearance - T op [...]

  • Page 10

    www .desatech.com 1051 16-01D 10 INST ALLA TION Continued 44 1 / 4 " Min. 40 1 / 4 " Min. 36" Min. to Facing Wall 22 3 / 4 " Min. Facing Wall Wallboard Wallboard Gas Line Facing Wall (Base line) Note: Gas line may also be on opposite side. Figure 8 - Framing for Built-In Firebox Installation 1 1 / 2 " Max. 3/8" Max. 4&[...]

  • Page 11

    www .desatech.com 1051 16-01D 1 1 INST ALLING GAS LINE  W ARNING: A  qualied ser - vic e perso n must con nect  heate r to gas supply . Follow all local codes. IMPORT ANT : See Connecting to Gas Supply in your log set owner ’ s manual for details on gas hookup. Y ou may run the gas line from either side of the reb[...]

  • Page 12

    www .desatech.com 1051 16-01D 12 If a sediment trap is not incorporated as a part of the gas utiliz atio n equ ipme nt, one shall be inst alle d as close to the inlet of the equipment as practical at the time of installation, as per ANS Z223.1/NFP A 54 . See Figure 14. Prepare incoming black iron gas line with T eon tape or pipe joint compound ([...]

  • Page 13

    www .desatech.com 1051 16-01D 13 Figure 15 - Locating Electrical Connection and Gas Connection on Either Side of Fireplace Cover Plates Electrical Connection Access Hole Gas Connection Access Hole Note: A 120V supply connection to the leads to the receptacle must be provided for use with the optional blower kit whether installed during or after ini[...]

  • Page 14

    www .desatech.com 1051 16-01D 14 Figure 17 - Optional Blower Wiring Diagram INST ALLA TION Continued HEA T DEFLECTIVE HOOD INST ALLA TION The factory supplied heat deective hoods must be installed inside the replace opening on both sides for the safe operation of the unit as shown in Figure 19. 1. Remove protective covering from hoods. 2. Pos[...]

  • Page 15

    www .desatech.com 1051 16-01D 15 OPERA TING GUIDELINES AND MAINTENANCE INSTRUCTIONS Whe n lit for the rst time , a ven t- fre e log hea te r will emit a sl ight o dor for a bout an ho ur or two . This is a normal occ urre nce which is due to the “curi ng” of the lo gs and th e “bur n-in ” of inte rna l p aint s and lubr ica nts used in t[...]

  • Page 16

    www .desatech.com 1051 16-01D 16 ILL USTRA TED P ARTS BREAKDOWN MODEL FBST **These items are used on both sides of fireplace. 8** 14 16** 16** 16** 7-1 7-2 2 16** 1 1** 16** 12 6 6 6 15 15 15 15 13 13 10** 5** 15 15 15 15 6 6 15 15 4 15 15 15 15 15 15 15 4 14 14 16** 16** 8** 16** 16** 7-1 9** 15 1 3[...]

  • Page 17

    www .desatech.com 1051 16-01D 17 P ARTS LIST MODEL FBST This list contains replaceable parts used in your rebox. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 *** Firebox Assembly 1 2 *** Firebox Bottom 1 3 *** Firebox T op 1 4 23982 T op Spacer 4 5[...]

  • Page 18

    www .desatech.com 1051 16-01D 18 TECHNICAL SERVICE Y ou may have further questions about installatio n, operation or troubleshooting. If so, contact DESA at 1-866-672-6040. Y ou can also visit DESA T echnical Service web site at www .desatech.com . ACCESSORIES Purcha se these rebox accessori es from your local deal er . If they can not supply th[...]

  • Page 19

    www .desatech.com 1051 16-01D 19 NO TES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________________[...]

  • Page 20

    LIMITED WARRANTY VENT -FREE FIREBO X DESA warrants this product to be free from defects in materials and components for four (4) years from the date of rst purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. T o make a claim under this warranty the Bill of Sale [...]