Vector VEC049C manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Vector VEC049C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vector VEC049C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Vector VEC049C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Vector VEC049C should contain:
- informations concerning technical data of Vector VEC049C
- name of the manufacturer and a year of construction of the Vector VEC049C item
- rules of operation, control and maintenance of the Vector VEC049C item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vector VEC049C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vector VEC049C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vector service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vector VEC049C.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Vector VEC049C item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    4140 S.W . 28TH W A Y • FT . LAUDERDALE, FL 33312 TEL 954.584.4446 • F AX 954.584.5556 TOLL-FREE: (866) 584-5504 OWNER’S MANUAL THIS MANUAL CONT AINS IMPORT ANT INFORMATION REGARDING SAFETY , OPERA TION, MAINTENANCE AND STORAGE OF THIS PRODUCT . TO A VOID POSSIBLE INJURY OR PROPER TY DAMAGE, PLEASE READ THIS INSTRUCTION MANUAL CAREFULL Y BEFO[...]

  • Page 2

    IMPORT ANT SAFETY INFORMA TION To ensure reliable ser vice, your power inverter must be installed and used properly . Please read the installation and operating instructions thoroughly prior to installation and use. Pay particular attention to the W ARNING and CAUTION statements in this manual. The CAUTION statements advise against certain conditio[...]

  • Page 3

    CONTENTS 1.0 INTRODUCTION 1.0 Basic T our of Inver ter . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 Maxx SST Safety Features . . . . . . . . . . . . . . . . . . .[...]

  • Page 4

    1.0 INTRODUCTION Y our new V ector MAXX SST inver ter is one in a series of the most advanced DC to AC inverters available. With proper care and appropriate usage, it will provide years of dependable ser vice in your car , truck, RV or boat. The MAXX SST supplies continuous power and peak watts, in the form of three plug-in outlets ready to deliver[...]

  • Page 5

    FIGURE 1 – FRONT P ANEL FIGURE 2 – BACK P ANEL 5 1 3 2 1 3 4 2 5 1) THREE NORTH AMERICAN ST ANDARD OUTLETS 2) GREEN LED SHOWS UNIT IS OPERA TING 3) RED LED SHOWS UNIT IS SHUT DOWN 4) ON/OFF SWITCH 4 1.2 MAXX SST SAFETY FEA TURES BUIL T -IN AUTOMA TIC SAFETY FEA TURES INCLUDE: •O verload and over-temperature shutdown activated if AC output exc[...]

  • Page 6

    MAXX SST™ inverters are ideal for powering: • TV/VCR combinations • Refrigerator/freezers • Lights • Radio receivers/transceivers •H eavy duty power tools & chargers • Stereo systems • Small microwave ovens •H ousehold appliances • Computers and peripheral equipment •D ry and/or wet-and-dr y vacuums • Sump pumps, motors [...]

  • Page 7

    2.0 INVERTER APPLICA TIONS Aside from issues of supplying power to higher wattage appliances, inverters must be supplied with a constant source of high current 12VDC from a bank of batteries. At full watt load, the DC input requirements are up to 15 amps at 12VDC. Read and comply with the following applications, and your inverter will give you year[...]

  • Page 8

    3.0 THEOR Y OF OPERA TION MAXX SST™ inverters change 12VDC into 110/120V AC RMS, electrical power . This is accomplished in two steps. (See FIGURE 4 ). The first stage raises the 12VDC input to 145VDC. The advanced design of the DC-to-DC first stage uses high-frequency conversion techniques that replace bulky and heavy transformers found in older[...]

  • Page 9

    NOTE: Because of wave-shape differences, using standard digital or analog voltmeters may not correctly read the inverter output voltage. Unless a true RMS voltmeter such as a "Fluke 87" , "Fluke 8060A" , "Beckman 4410" or "T riplet 4200" is used, the reading will be from 2 to 20 volts low . 4.0 OPERA TION NOT[...]

  • Page 10

    APPLIANCE AMPS@ W A TTS@ 110/120V AC 110/120V AC COMPUTER AND MONITOR 4 440 PORT ABLE V ACUUM 4.6 506 8-CUP COFFEE MAKER 5.5 605 ELECTRIC TRIMMER 5.5 605 1/2" HAMMER-DRILL 5.5 605 RECIPROCA TING SA W 6 660 V ACUUM CLEANER 7.2 792 1-1/8" ROT ARY HAMMER 7.8 858 1/6 H.P . SUBMERSIBLE SUMP PUMP 8 880 COMP ACT MICROW A VE OVEN 8.5 935 10"[...]

  • Page 11

    Inductive loads, such as TVs and stereos, require more current to operate than do resistive loads with the same wattage rating. Induction motors, as well as some TVs, may require two to six times their rated wattage to start up. Because the MAXX SST™ inverters have a peak watt power rating, many such appliances and tools may be safely operated. T[...]

  • Page 12

    Figure 6 – Batter y Operating Time For example, as shown in FIGURE 6 , using a 400 amp hour batter y (batteries), if the average power usage will be 1000 watts, the operating time will be about 150 minutes. A larger capacity batter y will deliver more operating time between recharges. NOTE: The manufacturer recommends conser vative estimates when[...]

  • Page 13

    5.0 INST ALLA TION MAXX SST™ inverters will provide you with various watts of continuous, electrical power (See Models Specification Chart Page 18) when powered by a 12VDC source such as is found in a vehicle or multiple batter y configuration as shown in FIGURE 7 . This manual does not describe all of the possible types of batter y , batter y ch[...]

  • Page 14

    In all marine applications, DO NOT install the inverter below or near the waterline, and keep the inverter away from moisture and water . Use ONL Y non-corrosive marine fasteners and fittings for installation. Only con- nect the inverter’ s DC input to existing wiring (which must be approved for marine use) rated specified gauge, cable and length[...]

  • Page 15

    5.4 QUICK OPERA TIONAL CHECKOUT OR EMERGENCY USE YOU WILL NEED: • One heavy-duty jumper cable set with specified A WD wire rating (See Page 18) • One fully-charged automobile batter y • A common, slip joint pliers for loosening and tightening terminal nuts TEST PROCEDURE: 1. Remove the plastic terminal covers and terminal nuts. 2. Identify th[...]

  • Page 16

    PRELIMINARY INST ALLA TION NOTES: The inverter has four slots in its mounting bracket that allow the unit to be fastened against a bulkhead, floor , wall or other flat sur face. Ideally , the mounting surface should be cool to the touch. It is more electrically efficient to use longer AC wiring than DC wiring, so install the inverter as close as po[...]

  • Page 17

    9. Crimp or clamp on a heavy-duty , batter y-connection terminal to the other end of the negative (–) and positive (+) cable. Connect the negative (–) bat- ter y terminal cable to the negative (–) batter y terminal connector . 10. Ensure the inverter power switch is in the off position ( see FIGURE 1 ). 11. Connect the ring terminal end of th[...]

  • Page 18

    18 Maximum Continuous Power 1000 W atts 1200 W atts 1500 W atts 2000 W atts 2500 W att Surge Capacity (Peak Power) 2000 W atts 2400 W atts 3000 W atts 4000 W atts 5000 W atts No Load Current Draw (switch on) 0.6 amps 1.3 amps 1.3 amps 1.3 amps 1.8 amps Max. Efficiency Approximately 90% 90% 90% 90% 90% Input V oltage 10.5–15.5VDC 10.5–15.5VDC 10[...]

  • Page 19

    7.0 SER VICE & P ARTS For ser vice on the inverters, contact the T echnical Support Depar tment at: VECTOR MANUF ACTURING, L TD 4140 S.W . 28th W ay • Ft. Lauderdale, Florida 33312 T el. (954) 584-4446 • Fax (954) 584-5556 • T oll-free: (866) 584-5504 8.0 TROUBLESHOOTING 8.1 COMMON PROBLEMS: POWER TOOLS AND MICROW A VE OVENS WON’T ST AR[...]

  • Page 20

    8.2 TROUBLESHOOTING GUIDE TROUBLE/ INDICA TION POSSIBLE CAUSE SUGGESTED REMEDY No AC output – DC input below Recharge or replace red LED lit 10 volts batter y No AC output – Excessive appliance Reduce load-wait for red LED lit load-thermal shutdown inverter to cool. T urn off Low batter y alarm Bad connection T ighten all DC sounds continuously[...]

  • Page 21

    10. W ARRANTY VECTOR 2 YEAR LIMITED W ARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of V ector Manufacturing, Ltd., regarding this product. There is no other warranty other than those described herein. This V ector Manufacturing, Ltd. product is warranted, to t[...]