Go to page of
Similar user manuals
-
Indoor Fireplace
Vermont Casting NVC43
28 pages 1.12 mb -
Indoor Fireplace
Vermont Casting 7TDVP3564
3 pages 0.44 mb -
Indoor Fireplace
Vermont Casting 3225
44 pages 2.71 mb -
Indoor Fireplace
Vermont Casting DVHVAC36
32 pages 1.82 mb -
Indoor Fireplace
Vermont Casting VCEF26
12 pages 0.44 mb -
Indoor Fireplace
Vermont Casting DV360
56 pages 4.35 mb -
Indoor Fireplace
Vermont Casting DTV38s2
48 pages 16.24 mb -
Indoor Fireplace
Vermont Casting RHEDV32
38 pages 0.68 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Vermont Casting IRFSDV24, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vermont Casting IRFSDV24 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Vermont Casting IRFSDV24. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Vermont Casting IRFSDV24 should contain:
- informations concerning technical data of Vermont Casting IRFSDV24
- name of the manufacturer and a year of construction of the Vermont Casting IRFSDV24 item
- rules of operation, control and maintenance of the Vermont Casting IRFSDV24 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vermont Casting IRFSDV24 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vermont Casting IRFSDV24, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vermont Casting service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vermont Casting IRFSDV24.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Vermont Casting IRFSDV24 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 Irving Oil 10004000 Installation Instructions and Homeowner ’ s Manual INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER Freestanding Direct V ent Fireplaces IRFSDV24 IRFSDV34 10004000 0102 Rev . 0 WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJUR[...]
-
Page 2
2 Irving Oil 10004000 Installation Instructions ................................................................................................................ 3 Important Curing/Burn Information ..................................................................................... 3 Locating Your Fireplace .........................................[...]
-
Page 3
3 Irving Oil 10004000 A - *Flat on wall B - *Room divider C - Island D - Cross corner E - Flat on wall corner * A & B must maintain a 12” (305 mm) clearance between the wall and side glass of fireplace. There is a minimum vertical rise required for the venting which varies depending on the application. The maximum horizontal run also has rest[...]
-
Page 4
4 Irving Oil 10004000 IRFSDV24 IRFSDV34 A 23 in (584 mm) A 26-14 in (667 mm) B 28-3/4 in (730 mm) B 31-1/2 in (800 mm) C 16-5/8 in (422 mm) C 19-3/8 in (492 mm) D 27-3/8 in (695 mm) D 30 in (762 mm) E 9-1/2 in (241 mm) E 10 in (254 mm) F 13-7/8 in (352 mm) F 15-1/2 in (394 mm) G 4 in (102 mm) G 4-1/2 in (1 14 mm) H 23 in (584 mm) H 26-1/4” (667 m[...]
-
Page 5
5 Irving Oil 10004000 Max. Max. Input Input Model Fuel Gas Control BT U/h BT U/h IRFSDV24RN Nat Millivolt Hi/Lo 20,000 14,000 IRFSDV24RP Prop Millivolt Hi/Lo 20,000 1 5,000 IRFSDV34RFN Nat Radio Frequency 30,0 00 21,000 IRFSDV34RFP Prop Radio Frequency 30,000 22,500 Natural LP (Propane) Input Minimum 5.5” wc 1 1” wc Input Maximum 14” wc 13”[...]
-
Page 6
6 Irving Oil 10004000 The remote ON/OFF switch can not be fitted to units using the Honeywell Radio Frequency control valve. If the fireplace has been fitted with the Radio Frequency Control Valve, the ON/OFF function is controlled by the remote handset. (See the Comfort Control Valve Operating Instruction Section). Install on/off switch assembly o[...]
-
Page 7
7 Irving Oil 10004000 Canadian Installations US Installations A = Clearance above grade, veranda, porch, 12 inches (30cm) 12 inches (30 cm) deck, or balcony B = Clearance to window/door that may be opened 6 in (15cm) for appliances<10,000 Btuh 6 in (15cm) for appliances < 10,000 (3kW), 12 in (30cm) for appliances > Btuh (3kW), 9 in (23cm) [...]
-
Page 8
8 Irving Oil 10004000 584-15 Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. A = Combustible 6"(152mm) Noncombustible 2"(50mm) B = Combustible 6"(152mm) Noncombustible 2"(50mm) A Balcony - with no side wall G = Combustible 24"(610mm) Non[...]
-
Page 9
9 Irving Oil 10004000 Before joining elbows and pipes apply a bead of high temperature sealant to the crimped end of the elbow or pipe. Join the pipes using a 2” (50mm) overlap and secure the joints with three (3) sheet metal screws (Fig. 11). Wipe off excess sealant. There are polished brass decorative rings available to hide the exposed piping [...]
-
Page 10
10 Irving Oil 10004000 VERTICAL SIDEWALL APPLICATIONS Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to. The graph, on page 11, showing the relationship between vertical and horizontal[...]
-
Page 11
11 Irving Oil 10004000 Horizontal Dimension From The Outside Face Of The Wall To The Center Of The Fireplace Vent Flange Vertical Dimension From The Floor Of The Fireplace To The Center Of The Horizontal Vent Pipe TO USE THE VENT GRAPH SIDEWALL VENTING GRAPH ( Dimensions In Feet) 1. Determine the height of the center of the horizontal vent pipe exi[...]
-
Page 12
12 Irving Oil 10004000 STEP 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size (Fig. 17). (For combustible walls first frame in opening. Fig. 17) COMBUSTIBLE WALLS : Cut a 9-3/8”H x 9-3/8” [...]
-
Page 13
13 Irving Oil 10004000 When it is not possible to meet the required vent terminal clearances of 12 inches (305mm) above grade level a snorkel vent kit is recommended. It allows installation depth of down to 7 “ (178mm) below grade level. The 7 “ is measured from the center of the horizontal vent pipe as it penetrates through the wall. If ventin[...]
-
Page 14
14 Irving Oil 10004000 If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as protruding wall face (Fig. 25). This Gas Fireplace has been [...]
-
Page 15
15 Irving Oil 10004000 installations. From 0 to a maximum of 8’ of vent pipe can be used between elbows (Fig. 25). • 7DVCS must be used to support offsets (Fig. 26). This application will require that you first determine the roof pitch and use the appropriate starter kit. (See Venting Components List) The minimum height of the vent above the hi[...]
-
Page 16
16 Irving Oil 10004000 CRIMPED END VENTING COMPONENTS Starter Kit-Model 7FSDVSK-Sidewall Venting Starter Kit-Model 7TDVSKV-Vertical Venting for 7DVSKV-A order 1/12 to 6/12 roof pitch for 7DVSKV-B order 7/12 to 12/12 roof pitch for 7DVSKV-F order flat roof Starter Kit-Model 7FSDVSKS-Snorkel Kit for Below Grade Installation 45˚ elbow kit 7FSDVT45G f[...]
-
Page 17
17 Irving Oil 10004000 Starter Kit - Model 7TFSMSK Starter Kit-Model 7TFSDVSK-Sidewall Venting Starter Kit-Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSK-F order flat roof Starter Kit-Model 7TFSDVSKS-Snorkel Kit for Below Grade Installation 45˚ elbow kit 7TFSDV45[...]
-
Page 18
18 Irving Oil 10004000 Only glass approved by the Vermont Castings, Majestic Products Company may be used for replacement. 1. Shut off gas (See Lighting Instructions). 2. Let the unit cool if it has been operating. 3. Open two side doors 4. Open the clamps on two sides. 5. Pull the frame forward. 6. To reinstall window frame assembly follow the abo[...]
-
Page 19
19 Irving Oil 10004000 1. It is important to keep the burner and the burner compartment clean. This must be done periodically, at least once per season (See Cleaning Procedure). 2. Clean the brass trim using a soft clean cloth, slightly dampened with lemon oil and buff with a soft clean cloth. Do NOT use brass polish or household cleaners as these [...]
-
Page 20
20 Irving Oil 10004000 RN/RP Models For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ knob located near the center of the gas control valve (See Fig. below). It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the pictorials illustrated belo[...]
-
Page 21
21 Irving Oil 10004000 OPTIONAL GOLD TRIM KIT OPTIONAL FRAME WINDOW TRIM KITS A decorative gold plated window trim kit Model #VT1G00 RFSDV24TKG is available for the IRSFD24 Freestanding Fireplace. The kit contains: 1 Gold-plated Window Trim 4 Magnets INSTALLATION PROCEDURE 1. Unpack the kit and confirm all parts are present. 2. Remove all the prote[...]
-
Page 22
22 Irving Oil 10004000 1. STOP! Read the safety information above on this page. 2. Turn off all electrical power to the fireplace appliance. 3. For MN/MP/TN/TP appliances only, go on to Step 4. for RN/RP turn the On/Off switch to “OFF” position or set thermostat to lowest level. 4. Open control access panel. 5. Push in gas control knob slightly[...]
-
Page 23
23 Irving Oil 10004000 OPERATING INSTRUCTIONS FOR RFN/RFP COMFORT CONTROL VALVE Mode Auto On/Off Countdown Timer Fan Display Room Temperature Set Temperature Flame Height Level Fan Speed Level Countdown Timer Low Battery Flame Up Increases Flame Height, Fan Speed Timer, or Set Point Down Decrease Flame, Fan Speed Timer or Set Point The Comfort Cont[...]
-
Page 24
24 Irving Oil 10004000 FAN Antenna Red White Red White Pilot Assembly Valve (Bottom View) Fan Delay Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. T o change the timer level, press the time key followed by an arrow key . Pushing the key once will change the timer by 10 minutes. Auto Mode In the AUTO mode[...]
-
Page 25
25 Irving Oil 10004000 TROUBLE SHOOTING THE GAS CONTROL SYSTEM Set manual s witch to local or remote Light pilot burner Five min ute wait period Did the LED stop blinking? No Re view LED f ailure analysis Release pilotstat knob T ur n pilotstat knob from PILO T to ON Cycle s witch once and leav e in remote. Press any ke y on transmitter f or recogn[...]
-
Page 26
26 Irving Oil 10004000 Code # Part Description IRFSDV24 IRFSDV34 1 Log Set Complete 10003538 100001763 1a Log ember bed --- KR7 1b Log - Front left KR13 KR8 1c Log - Front right KR14 KR9 1d Log - Rear — KR10 1e Log - T op left — KR1 1 1f Log - T op right — KR12 1g Log - Rear left KR15 --- 1h Log - Rear right KR16 --- 2* Lava Rock 57897 57897 [...]
-
Page 27
27 Irving Oil 10004000 Code# Part Description IRFSDV24 IRFSDV34 20 Fan Assembly with bracket 54103 54103 21 Remote ON/OFF Switch 53606 53606 22* Wiring Harness - Remote Switch 57265 57265 23* Remote ON/OFF Switch Kit (includes bracket) 53859 53859 24 Window Frame Assembly (complete with glass) 10003973 10003966 25* Window Glass with Gasket Assembly[...]
-
Page 28
28 Irving Oil 10004000 REPLACEMENT PARTS L O H I PILOT ADJ PILOT ON OFF 1c 1b 1g 1h 3 14 18c/d 20 37 21 24 27 28 29 30 32 9c/d 11a 10 13b 8a/b 11a 13a 14 11b 39 13b 17 15 O N P I L O T O F F 14 18a/b 38 1a 1b 1c 1d 1e 1f IRFSD V24 Log Set IRFSD V34 Log Set 34 40 31 9a/b[...]