Vermont Casting NVBR36 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Vermont Casting NVBR36, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vermont Casting NVBR36 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Vermont Casting NVBR36. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Vermont Casting NVBR36 should contain:
- informations concerning technical data of Vermont Casting NVBR36
- name of the manufacturer and a year of construction of the Vermont Casting NVBR36 item
- rules of operation, control and maintenance of the Vermont Casting NVBR36 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vermont Casting NVBR36 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vermont Casting NVBR36, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vermont Casting service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vermont Casting NVBR36.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Vermont Casting NVBR36 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    950 NVB cov er 2/1/01 Decorative Gas Appliances PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these in- structions may result in a possible fire hazard and will void the warranty . W ARNING: If the information in this manu[...]

  • Page 2

    2 NVB Ser ies B- V e nt Gas F ireplace 7412950 T able of Contents Thank you and Congratulations on your purchase of a CFM Corporation fireplace. PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these inst[...]

  • Page 3

    3 NVB Ser ies B- V e nt Gas F ireplace 7412950 General Information This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. FOR U.S.A Installations follow local codes and/or the cur - rent National Fuel Gas Code. [...]

  • Page 4

    4 NVB Ser ies B- V e nt Gas F ireplace 7412950 Fig. 1 NVBR36 Series specification and framing dimensions. NVBR36 Series Gas Appliance FP561 36" (914mm)  " (356mm)  " (337mm) 40" (1016mm) 36" (914mm) 3" (76mm)  " (16mm) 45  " (1 162mm) 45  " (1 162mm) ?[...]

  • Page 5

    5 NVB Ser ies B- V e nt Gas F ireplace 7412950 NVBR42 Series Gas Appliance FP563 Fig. 3 NVBR42 Series specification and framing dimensions. 42" (1067mm)  " (356mm)  " (337mm) 46" (1 168mm) 36" (914mm) 3" (76mm)  " (16mm) 49" (1245mm) 49" (1245mm)  " (13mm) [...]

  • Page 6

    6 NVB Ser ies B- V e nt Gas F ireplace 7412950 Clearance to Combustibles Appliances T op ..........................................................0” (0 mm) Bottom .....................................................0” (0 mm) Side .........................................................0” (0 mm) Back ........................................[...]

  • Page 7

    7 NVB Ser ies B- V e nt Gas F ireplace 7412950 Framing and Finishing Check appliance to make sure it is levelled and properly positioned. The appliance should only be mounted on the following sur- faces: • A flat combustible (burnable) surface. • A raised wooden platform. • A concrete block or other solid object placed beneath each of the fo[...]

  • Page 8

    8 NVB Ser ies B- V e nt Gas F ireplace 7412950 WF597 NVC (from FP528) 12/2/97 Parts Identification and Chase Installation Fig. 7 Parts identification and system installation. (Insulation methods shown are optional for cold climate, not a requirement for unit operation.) FP597 *Do not install header until unit is in place. See Page 8, "Mounti[...]

  • Page 9

    9 NVB Ser ies B- V e nt Gas F ireplace 7412950 24 V AC HOT 24 V AC RTN ON-OFF SWITCH NOV A SIT 822 V ALVE HONEYWELL S8600 B IGNITION MODULE 120 V AC RTN 40V A TRANSFORMER 120 V AC HOT BLACK BLACK BLACK BLACK BLACK BLACK BLACK WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE BLACK FP670 NOV A SIT 822 V AL VE WIRING DGRM. ?[...]

  • Page 10

    10 NVB Ser ies B- V e nt Gas F ireplace 7412950 EB-1 Electrical Box The fireplace, when installed, must be elec- trically connected and grounded in accor- dance with local codes or , in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. For USA installations, follow local codes and the National Electrical Code, ANSI/ [...]

  • Page 11

    1 1 NVB Ser ies B- V e nt Gas F ireplace 7412950 FP567 Fig. 13 V enting configurations.    V enting Runs                ?[...]

  • Page 12

    12 NVB Ser ies B- V e nt Gas F ireplace 7412950 Operating Instructions Glass Information Only glass approved for use in Majestic Fireplaces products may be used for re- placement. • Glass doors are optional. The appliance may be operated safely without glass doors. • The use of any non-approved replacement glass will void all product warranties[...]

  • Page 13

    13 NVB Ser ies B- V e nt Gas F ireplace 7412950 LG148 NVB42 log set 1/30/01 djt Left Rear Log Left Cross Log Middle Cross Log Right Cross Log Right Rear Log Ember Left Log Embers Grate Lava Rock Ember Right Fig. 16 NVB42 log placement. LG148 Under no circumstances should lava rock be placed on any part of the burner assem- bly . First Firing Upon c[...]

  • Page 14

    14 NVB Ser ies B- V e nt Gas F ireplace 7412950 LG151 NVB36 log flames 2/2/01 djt Red Glow Embers LG151 Fig. 19 NVB36 flame appearance. L G1 50  N VB 42 l og f la me s 2 /1 /0 1 d jt LG150 Fig. 20 NVB42 flame appearance.[...]

  • Page 15

    15 NVB Ser ies B- V e nt Gas F ireplace 7412950 A. This heater has a pilot which must be lit manu- ally . When lighting the pilot follow these instructions exactly . B. BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T TO DO IF YOU[...]

  • Page 16

    16 NVB Ser ies B- V e nt Gas F ireplace 7412950 1/2" Gas Supply 1/2" x 3/8" Shut-off V alve 3/8" Union 3/8" Nipple 3/8" Nipple GF598 nvb GAS SUPPL Y INST ALL 12/4/97 Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas V alve (EN or EP) A. This fireplace is equipped with an ignition device which[...]

  • Page 17

    17 NVB Ser ies B- V e nt Gas F ireplace 7412950 T roubleshooting FP396 Gas Supply On • Supply Line Hooked up • Shutoff V alve Open NO NO NO NO • Lockout has engaged. W ait 60 seconds and try again. • Piezo not tight enough for good ground. • For spark at electrode while depressing Piezo (Red Button) 1/8" gap to pilot hood needed. •[...]

  • Page 18

    18 NVB Ser ies B- V e nt Gas F ireplace 7412950 FP649 • T urn gas supply off • T urn ON/OFF Switch to call for heat. NO NO NO NO NO NO NO Spark across Ignitor Sensor gap Power to module (24V nominal) YES YES YES YES YES YES YES • T urn gas on Pilot burner lights? Spark stops when pilot is lit? Main Burner lights? • Replace Module ST ART •[...]

  • Page 19

    19 NVB Ser ies B- V e nt Gas F ireplace 7412950 In order to properly clean the burner and pilot assem- bly , turn off the gas to the unit, open the glass door (if used), remove logs exposing the burner and pilot assembly . Clean all foreign materials from the top of the burner . Check to make sure that burner parts are clean. Visually inspect pilot[...]

  • Page 20

    20 NVB Ser ies B- V e nt Gas F ireplace 7412950 NVB Series Ref. Description NVB36 NVB42 1. Logs - Complete Set 20003868 20003910 1a. Log - Left Rear 20003862 20003904 1b. Log - Right Rear 20003863 20003905 1c. Log - Right Cross 20003864 20003906 1d. Log - Left Cross 20003865 20003865 1e. Log - Center Cross -- 20003907 1f. Log - Left Ember (Long) 20[...]

  • Page 21

    21 NVB Ser ies B- V e nt Gas F ireplace 7412950 NVB (continued) Ref. Description NVB36 NVB42 Door T rack - Brass 3067102 3072102 1 1. Side Brick - Left 3030104 3030104 12. Back Brick 3030102 3032102 13. Side Brick - Right 3030160 3030160 14. Ceramic Panel - Left 3043132 3051 120 15. Ceramic Panel - Right 3043133 3051 1 19 16. Glass 7540637 7540642 [...]

  • Page 22

    22 NVB Ser ies B- V e nt Gas F ireplace 7412950 Optional Accessories Fan Kit The FK12 fan kit is available for use on the NVBC36 and NBVC42 model appliances only . Auxiliary fan systems increase the efficiency of the cir- culation of the heating air . The FK12 fan assembly is a fixed speed fan system and does not allow for variable speed control.[...]

  • Page 23

    23 NVB Ser ies B- V e nt Gas F ireplace 7412950 BASIC W ARRANTY CFM Corporatio n (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and l[...]

  • Page 24

    2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation[...]