A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Vermont Casting RADVTBD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vermont Casting RADVTBD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Vermont Casting RADVTBD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Vermont Casting RADVTBD should contain:
- informations concerning technical data of Vermont Casting RADVTBD
- name of the manufacturer and a year of construction of the Vermont Casting RADVTBD item
- rules of operation, control and maintenance of the Vermont Casting RADVTBD item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vermont Casting RADVTBD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vermont Casting RADVTBD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vermont Casting service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vermont Casting RADVTBD.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Vermont Casting RADVTBD item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INST ALLER / CONSUMER SAFETY INFORMA TION 20012697 8/07 Rev . 1 PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE. W ARNING! IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. FOR YOUR SAFETY Installation and service must be performed[...]
-
Page 2
2 2 Radiance Direct Vent Gas Heater 20012697 PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a V ermont Castings stove. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a po[...]
-
Page 3
3 Radiance Direct Vent Gas Heater 20012697 The Ra dian ce D irec t V e nt Room H eate r , M odel Nos . R ADVTCB, R A DVT EB, R A DVT MB, R A DVT BS, R A DVTCH , R A DV T VG, R A DVT BD, R ADV T BB, R A DV TCG, R A DVTGG , R A DV TSG, R A DVTCC B, R A DVTCEB , R A DV TCMB , R A DV TCBS, R A D - V T CCH, R ADVTC VG, R ADVTCBD , R ADVTCBB, R ADVTCCG, [...]
-
Page 4
4 4 Radiance Direct Vent Gas Heater 20012697 29 " (758 mm) 31" (787 mm) 7" Outer Dia. (178 mm) Flue Collar L C 4 " (120 mm) 14 " (378 mm) ST126 RDV40 dimensions 10/99 RADIANCE 28" (71 1 mm) 5" (127 mm) 18 " (464 mm) Supply Inlet 9 " (241 mm) RADVT Models [...]
-
Page 5
5 Radiance Direct Vent Gas Heater 20012697 Installation Requirements The installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFP A 54 - latest edition. (EXCEP- TION: Do not derate this appliance for altitude. Main- tain the manifold pressure at 3.5” w .c. for Natural Gas, and[...]
-
Page 6
6 6 Radiance Direct Vent Gas Heater 20012697 Parallel Installation: Minimum Clearance and Flue Centerline Fig. 3 Parallel installation, minimum back and side clear- ances, and flue centerlines. ST130 42" (1070mm) Min. Alcove Width 48" (1220mm) Max. Alcove Depth 6"[...]
-
Page 7
7 Radiance Direct Vent Gas Heater 20012697 Gas Specifications Max. Min. Inp ut Input Mo del Fuel Gas Control BT U /h BTU/h RADVT Series Nat Millivolt 38,000 25,000 RADVT Series Prop Millivolt 36,000 25,000 RADVTC Series Nat Comfort Control 38,000 25,000 RADVTC Series Prop Comfort Control 36,000 25,000 Weight: Fully assembled; 350 lbs. Natural LP ([...]
-
Page 8
8 8 Radiance Direct Vent Gas Heater 20012697 V ertical T ermination A vertical vent system must terminate no less than 8’ (2.44 m) and no more than 40’ (12 m) above the ap- pliance flue collar . A restrictor plate (supplied) must be used, where specified, in all vertically terminated vent systems. (Refer to Figure 8) NOTE: The restrictor plat[...]
-
Page 9
9 Radiance Direct Vent Gas Heater 20012697 V ent T ermination Clearances Y our stove is approved to be vented either through the side wall, or vertical through the roof. • CFM Corporation does not require any opening for inspection of vent pipe. • Only CFM Corporation, Simpson DuraV ent and Selkirk Corporation venting components specifi- cally[...]
-
Page 10
10 10 Radiance Direct Vent Gas Heater 20012697 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev . 12/05/01 sta INSIDE CORNER DET AIL V A G N N CFM145a General V ent[...]
-
Page 11
1 1 Radiance Direct Vent Gas Heater 20012697 Fig. 12 T ermination clearances. Outside Corner Inside Corner T ermination Clearances T ermination clearances for buildings with combustible and noncombustible exteriors. G = Combustible 6" (152 mm) Noncombustible 2" (51 mm) F = Combustible 6" (152 mm) Noncombustible 2" (51 mm) G Balc[...]
-
Page 12
12 12 Radiance Direct Vent Gas Heater 20012697 V enting Requirements and Options Approved V ent System Components The Radiance Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appropriate listed venting components specified on this page. These parts are availab[...]
-
Page 13
13 Radiance Direct Vent Gas Heater 20012697 V ertical T ermination Cap 4DT -VC CFM V ent Components The following kits are available to meet the needs of most installations. All pipe has a 7” outer diameter and includes a 4” diameter inner section. A (CG) designa- tion indicates the part is finished in Charcoal Gray paint. Consult your dealer [...]
-
Page 14
14 14 Radiance Direct Vent Gas Heater 20012697 ST720 Radiance slide stove back 7/30/02 djt ST720 Fig. 13 Slide stove back just far enough to access rear leg holes. Assembly Procedures Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved for use with this heater may result in property [...]
-
Page 15
15 Radiance Direct Vent Gas Heater 20012697 ST347a JUV FK28 rheostat install 9/21/00 Rheostat Retaining Collar Rheostat Knob ST347a Fig. 18 Attach the fan rheostat. Rheostat Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. It is easiest to install fan kit before connecting gas line. If you [...]
-
Page 16
16 16 Radiance Direct Vent Gas Heater 20012697 V enting System Assembly General Information The Radiance is approved for installation only with the vent components listed on Pages 12 and 13. Follow the vent component instructions exactly . For U.S. installations: The venting system must con- form with local codes and/or the current National Fuel Ga[...]
-
Page 17
17 Radiance Direct Vent Gas Heater 20012697 ST651 Fig. 23 Simpson Dura-V ent - install outer adapter pipe. ST652 dura v ent attach outer assy 4/20/01 djt ST649 dura vent attach inner assy 4/20/01 djt CEMENT ST649 Inner Adpater Pipe 1/4-20 x 3/8” Phil- lips Screws Fig. 22 Simpson DuraV ent - install inner adpater pipe. Install V ent Adap[...]
-
Page 18
18 18 Radiance Direct Vent Gas Heater 20012697 4. For CFM Vent Pipe only: If necessary , measure to determine the vertical length (X) of pipe required from the adapter pipe to the wall cutout centerline, including a 2” overlap at the joint. (Fig. 26) use a hacksaw or tin snips to trim the pipe as needed. ZCS103 Zero Clearance Sleeve & Firesto[...]
-
Page 19
19 Radiance Direct Vent Gas Heater 20012697 1 1. For CFM only: Install Charcoal Gray Pipe Rings (#7FSDRG) or Polished Brass Pipe Rings (#7FSDRP) at pipe joints, if desired. V ent T ermination Below Grade Install Snorkel Kit #7FSDVSKS when it is not possible to meet the required vent termination clearances of 12” (305 mm) above grade level. The sn[...]
-
Page 20
20 20 Radiance Direct Vent Gas Heater 20012697 7. Install the appropriate roof support and flashing, making certain that the upper flange of the flashing base is below the shingles. (Fig. 33) 8. Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward. 9. Instal[...]
-
Page 21
21 Radiance Direct Vent Gas Heater 20012697 Gasket Lock T ab Inlet End Outlet End ST922 T o T ermination T o Appliance Fig. 34 Joint connection. it by screwing the support plate to the top of the prop- erly framed ceiling joist opening, using screws provided. A round trim plate (TP)[...]
-
Page 22
22 22 Radiance Direct Vent Gas Heater 20012697 The Cathedral Ceiling Support (CCS) may be used in pitched or flat ceiling installations and comes with a support collar and a decorative two part square trim plate. Install by inserting the support box down through the framed joist opening (end with round hole first) in the ceiling using tin snips, [...]
-
Page 23
23 Radiance Direct Vent Gas Heater 20012697 from traffic areas such as walkways if it is less than 7’ (2.1 m) high. Refer to Pages 10, 1 1, Figures 1 1, 12 for more detail. Snorkel T ermination Window Well 12” (305 mm) Minimum Clearance Above Grade Level to Air Intake Grade [...]
-
Page 24
24 24 Radiance Direct Vent Gas Heater 20012697 If the wall is brick or concrete, and contains no com- bustible material, a 7” (178 mm) round penetration hole is adequate. The wall thimble is not required. The perforated straps of the horizontal termination provide a method of attachment. These can either be threaded through the opening or wall th[...]
-
Page 25
25 Radiance Direct Vent Gas Heater 20012697 Minimum Height Above Roof ST934 minimum height 6/07 Minimum Roof Pitch Height Flat to 7/12 1’0” Over 7/12 to 8/12 1’6” Over 8/12 to 8/12 2’0” Over 9/12 to 10/12 2’6” Over 10/12 to 1 1/12 3’3” Over 1 1/12 to 12/12 4’0” Over 12/12 to 14/12 5’0” Over 14/12 to 16/12 6’0” Over 1[...]
-
Page 26
26 26 Radiance Direct Vent Gas Heater 20012697 Rear Log LG488 Figure 48 2. Install the rear log by plac- ing it on the ember bed toward the back of the firebox. (Fig. 48) The log should touch the back wall of the firebox. When the log is in place, the two (2) notches on the bottom of the log [...]
-
Page 27
27 Radiance Direct Vent Gas Heater 20012697 Figure 51 Left Cross Log Rear Log Right Cross Log Front Right Log Front Left Log Ember Bed LG490 Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the t[...]
-
Page 28
28 28 Radiance Direct Vent Gas Heater 20012697 Install ON/OFF Switch The switch assembly parts are found in the parts bag. 1. Attach switch assembly to left rear side of stove shroud (when facing shroud) using two screws and existing holes in shroud. (Fig. 52) 2. Run wires down back of stove, under bottom of rear shroud to valve. 3. Attach wires to[...]
-
Page 29
29 Radiance Direct Vent Gas Heater 20012697 ST477 Stardance pilot location 10/4/00 Fig. 54 Pilot Assembly location. ST476 Pilot As- sembly Flame & T emperature Adjustment For stoves equipped with HI/LO valves, flame adjust- ment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control valve. (Fig. 55)[...]
-
Page 30
30 30 Radiance Direct Vent Gas Heater 20012697 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn of f all electrical power to the fireplace. 3. Turn the On/Of f switch to “OFF” position, set the r[...]
-
Page 31
31 Radiance Direct Vent Gas Heater 20012697 T roubleshooting the Gas Control System (RADVT Series) NOTE : Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. SIT NOV A 820 MILLIVOL T V AL VE Symptom 1. Spark ignitor will not light 2. Pilot will not stay lit after carefully following lighting in[...]
-
Page 32
32 32 Radiance Direct Vent Gas Heater 20012697 Instructions for Comfort Control V alve RADVTC Series The Comfort Control valve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal. Operation 1. If the manual switch is in remote position, switch it to LOCAL. (Fig. 57) 2. [...]
-
Page 33
33 Radiance Direct Vent Gas Heater 20012697 Auto Mode In the AUTO mode, the room temperature, set tem- perature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons. When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The[...]
-
Page 34
34 34 Radiance Direct Vent Gas Heater 20012697 Light pilot burner Set manual switch to local or remote Release pilotstat knob. T urn pilotstat knob from PILOT to ON. If manual switch is set to LOCAL, did main burner light and fan turn on? T urn pilotstat knob to PILOT to turn off main burner . T urn pilotstat knob to OFF to turn valve completely of[...]
-
Page 35
35 Radiance Direct Vent Gas Heater 20012697 If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter . Does the transmitter display the room and temperture setting? If the settings is above room temperture on the transmitter , does the main valve and fan turn on? T urn pilotstat knob to OFF to turn valve com- [...]
-
Page 36
36 36 Radiance Direct Vent Gas Heater 20012697 Conversion Precautions Before proceeding, turn control knob on valve to OFF and turn gas supply OFF . T urn OFF any electricity that may be going to the appliance. Fuel Conversion Instructions W ARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufac[...]
-
Page 37
37 Radiance Direct Vent Gas Heater 20012697 2. Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 32, Fig. 57) 3. Remove motor top cap using a standard slotted screwdriver . Depress and turn center plunger until arrow points to correct screw . Red for LP and Blue for NG. NOTE: Plunger will “snap” in[...]
-
Page 38
38 38 Radiance Direct Vent Gas Heater 20012697 Burner Orifice Conversion 1. Remove three (3) 3/8” nuts on bottom side of burner pan. (Fig. 72) 2. Carefully remove ember bed by tilting the right side up and lifting out toward the right side of the unit. (Fig. 73) CO144 RF Pilot conversion 6/07 djt Pilot Orifice CO1044 Fig. 71 Remove pilot orifi[...]
-
Page 39
39 Radiance Direct Vent Gas Heater 20012697 T able 3. Air Shutter Adjustment Natural Gas Natural Gas LP Model High Altitude RADVT/RADVC 1/2” Open 1/2” Open 1/2” Open T able 4. High Altitude Orifice [Required for altitudes above 2000’ (610 m) up to 4500’ (1,370 m)] Input (BTU/h) Model Orifice Part # Minimum Maximum RADVT/RADVTC #33 / 0.1[...]
-
Page 40
40 40 Radiance Direct Vent Gas Heater 20012697 Maintenance Y our Radiance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly . Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician. Repla[...]
-
Page 41
41 Radiance Direct Vent Gas Heater 20012697 Gasket Replacement The Radiance Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer . Shut off the gas supply and allow the stove to cool. Wear saf[...]
-
Page 42
42 42 Radiance Direct Vent Gas Heater 20012697 NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200°C WIRE OR ITS EQUIV ALENT . F AN JUNCTION BO X F AN PO WER CORD Strain Relief Chassis Ground B L K GRN GRN WHT O N / O FF R he o st at Chassis Ground RHEOST A T / SNAPST A T[...]
-
Page 43
43 Radiance Direct Vent Gas Heater 20012697 10 1a 40 14 16 7 42 45 12697 RADVT/RADVTC parts 6/07 djt 37a,b,c 47 LOCAL REMOTE ON • PILOT OFF • LED 6 7 8 15 26a,b 27a 27b 27c 29 30 28 31 33 32 34 35a,b 44 36a,b 9 43 22 23 13 21 1 1 12 20 48 3 5 4 25 38 19 17 18 24 46 41 1 1c 1b 1e 1d 2 50 CFM Corporation reserves the right to make changes in desi[...]
-
Page 44
44 44 Radiance Direct Vent Gas Heater 20012697 Radiance Direct V ent Gas Heater (continued) Models: R ADVT S eries: R A D V TC B, R ADVTEB, R ADVTMB, R ADV TBS, RA D V TC H , R ADVT VG, R AD V TBD , R ADVTBB, R ADVTC Series: R AD V TC G, R ADV T GG, R ADVTSG, R ADVTCC B, R A D V TCE B, R AD V TC MB, R AD V TCBS, RA D V TC CH, R AD V TCV G, R ADVTCB[...]
-
Page 45
45 Radiance Direct Vent Gas Heater 20012697 Fuel Conversion Kits Conversion Kit, NG to LP - RADVTC Kit 20012900 Conversion Kit, NG to LP - RADVT Kit 20012729 Conversion Kit, LP to NG - RADVTC Kit 20012902 Conversion Kit, LP to NG - RADVT Kit 20012899 High Altitude Conversion Kit Kit 20013135 35b. Pilot Orifice #35 - LP T op Convertible 10002269 36[...]
-
Page 46
46 46 Radiance Direct Vent Gas Heater 20012697 Radiance Direct V ent Gas Heater (continued) Models: R ADVT S eries: R A D V TC B, R ADVTEB, R ADVTMB, R ADV TBS, RA D V TC H , R ADVT VG, R AD V TBD , R ADVTBB, R ADVTC Series: R AD V TC G, R ADV T GG, R ADVTSG, R ADVTCC B, R A D V TCE B, R AD V TC MB, R AD V TCBS, RA D V TC CH, R AD V TCV G, R ADVTCB[...]
-
Page 47
47 Radiance Direct Vent Gas Heater 20012697 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture. A rheostat provides for variable fan[...]
-
Page 48
48 48 Radiance Direct Vent Gas Heater 20012697[...]
-
Page 49
49 Radiance Direct Vent Gas Heater 20012697[...]
-
Page 50
50 50 Radiance Direct Vent Gas Heater 20012697[...]
-
Page 51
51 Radiance Direct Vent Gas Heater 20012697 LIMITED LIFETIME W ARRANTY CFM Corporation (hereinafter referred to as CFM) warrants that all cast iron parts, the combustion chamber , ceramic burner , and heat exchanger of every V ermont Castings gas product will be free of defective material or workmanship during the period the product is owned by the[...]
-
Page 52
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation[...]