Go to page of
Similar user manuals
-
Fan
Vermont Casting 2951
46 pages 0.95 mb -
Fan
Vermont Casting 2467
28 pages 6.12 mb -
Fan
Vermont Casting 2998
46 pages 0.95 mb -
Fan
Vermont Casting VCBV10
16 pages 0.36 mb -
Fan
Vermont Casting 2995
46 pages 0.95 mb -
Fan
Vermont Casting UE181L
14 pages 0.17 mb -
Fan
Vermont Casting ANSI Z83.7-2000
14 pages 0.41 mb -
Fan
Vermont Casting 3340
32 pages 0.62 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Vermont Casting UC241N, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vermont Casting UC241N one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Vermont Casting UC241N. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Vermont Casting UC241N should contain:
- informations concerning technical data of Vermont Casting UC241N
- name of the manufacturer and a year of construction of the Vermont Casting UC241N item
- rules of operation, control and maintenance of the Vermont Casting UC241N item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vermont Casting UC241N alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vermont Casting UC241N, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vermont Casting service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vermont Casting UC241N.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Vermont Casting UC241N item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Decorative Gas Appliance For Installation In Solid Fuel Burning Fireplaces 331 1243 7/04 Rev . 1 Certified to ANSI Z21.1 1.2A Standard D E S I G N C E R T I F I E D W ARNING If the information in this manual is not followed exactly , a fire or explosion may result causing property damage, personal injury or loss of life. Installation and Operating [...]
-
Page 2
2 331 1243 A TTENTION This unvented gas log heater has been certified by CSA and tested to conform to ANSI Z21.1 1.2 Gas Fired Room Heaters. Check local codes before installing this log heater . In some areas of the country , unvented gas log heaters are restricted. The installation and provision for combustion and ventilation air must conform with[...]
-
Page 3
3 331 1243 CARBON MONOXIDE POISONING MA Y LEAD TO DEA TH When used without fresh air , vent free gas logs may give off carbon monoxide, an odorless, poisonous gas. Some people such as pregnant women, people with heart or lung disease and persons at high altitudes are more affected by carbon monoxide than others. Early signs of carbon monoxide poiso[...]
-
Page 4
4 331 1243 Provisions for Adequate Combustion and V entilation Air This heater shall not be installed in a “ CONFINED SP ACE” or unusually tight construction unless provi- sions are provided for adequate combustion and ventilation air . The NA TIONAL FUEL GAS CODE, ANSI Z223.1/NFP A 54 defines a “CONFINED SP ACE” as a space whose volume is [...]
-
Page 5
5 331 1243 Fireplace Spacing Requirements The illustration in Figure 2 shows spacing requirements for your room with a hood installed (not included). W ithout a hood, you must maintain a minimum of 32” between the top opening of the firebox and the bottom of a mantel which protrudes out 12”. If you do not have at least 32” between the two, a [...]
-
Page 6
6 331 1243 A TTENTION: This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney . Heat is generated by realistic flames. This heater is designed for vent-free operation with flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters. NOTE: Where listed vented d[...]
-
Page 7
7 331 1243 • If the fireplace has glass doors, remove the glass doors and frame assembly or the upper door track. • If the upper door track has been removed, follow the instructions for Figure 3. If the upper door track remains, skip Figure 3 and follow the instructions for Figure 4. 2. If the upper door track has been removed, hold the adjusta[...]
-
Page 8
8 331 1243 Connection to Gas Supply 1. Place the burner assembly (grate and control package) in the fireplace. Center the assembly front to back and side to side. 2. Install the gas supply fitting to the gas supply pipe. Use pipe thread sealing compound, or T eflon tape, on the iron pipe threads only . Do not use on flared threads. 3. Connect the b[...]
-
Page 9
9 331 1243 Guidelines After your installer does the test burn, the log set should be operated either with the chimney open or , in the absence of a chimney , with a window open approxi- mately 1-2 inches. This operation should last for about 2-3 hours to cure the logs and dissipate any residual fumes from the new unit. This unvented gas log heater [...]
-
Page 10
10 331 1243 Thermostatic Control The thermostat control knob can be set to any comfort level between “HI” and “LO”. The thermostat will gradually modulate the heat output and flame height from higher to lower settings in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amoun[...]
-
Page 11
11 331 1243 Oxygen Depletion System For your safety , this appliance is equipped with an oxygen depletion system. This system senses the oxygen in the firebox and switches off the gas supply before the amount of oxygen falls below safe levels. (Fig. 12) Pilot ODS Sensor Flame Thermocouple Piezo Ignitor FP1505 Fig. 12 Pilot. Maintenance To clean the[...]
-
Page 12
12 331 1243 UC/UE181, UC/UE241 Series Unvented Gas Log Heaters Ref. Description UC/UE181 UC/UE241 1a. Log Assembly - 2 Larger Bottom Logs 4312759 4312760 1b. Log Åssembly - 3 Smaller T op Logs 4312761 4312762 2. Bag of Lava Rock (2 lbs.) (2 per Heater) 20000198 20000198 3. Flexline Gas Connector 3304177 3304177 4. Damper Clamp Assembly 7540310 754[...]
-
Page 13
13 331 1243 Failure to follow all instructions in this owner ’s manual will also void this warranty . CFM Home Products will not be liable for incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gi[...]
-