A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Viking NGIQ532T, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Viking NGIQ532T one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Viking NGIQ532T. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Viking NGIQ532T should contain:
- informations concerning technical data of Viking NGIQ532T
- name of the manufacturer and a year of construction of the Viking NGIQ532T item
- rules of operation, control and maintenance of the Viking NGIQ532T item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Viking NGIQ532T alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Viking NGIQ532T, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Viking service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Viking NGIQ532T.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Viking NGIQ532T item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA[...]

  • Page 2

    IMPORTANT: PLEASE READ AND FOLLOW • Before beginning, please read these instructions completely and carefully. • Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty • Please observe all local and national codes and ordinances. • The installer should leave these instructions with the consume[...]

  • Page 3

    BASIC SPECIFICATIONS T-SERIES GRILLS Description Cutout Width Cutout Depth Cutout Height Overall Width Overall Depth Gas Requirements Electrical Requirements Grill Burner Rating TilJSea r TM Burner Rating (if applicable) Smoker Burner Rating (If applicable) Side Burner Rating (If applicable) Rotisserie Burner Rating (If applicable) Approximate Ship[...]

  • Page 4

    BASIC SPECIFICATIONS E-SERIES GRILLS Description Cutout Width Cutout Depth Cutout Height Overall Width Overall Depth ,Sas Requirements Electrical Requirements Maximum Amp Usage Still Burner Rating TruSear TM Burner Rating (if applicable) Smoker Burner Rating (If applicable) Side Burner Rating (If applicable) Rotisserie Burner Rating (If applicable)[...]

  • Page 5

    GAS CONNECTION Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the grill rating plate agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas shut-off valve must be installed in an easily accessible location. All installer supplied parts must conf[...]

  • Page 6

    NATURAL FIXED PIPING CONNECTION Connection: Operating Pressure: Supply Pressure: Standard Residential 1/2" ID gas service line - 1/2" NPT male with 7/8" (2.2 cm) flare adapter. 4.0" W.C.R Nat. 6" to 10" W.C.R Nat. If in excess of 10" W.C.R, a step-clown regulator is required. Check with your local gas utility comp[...]

  • Page 7

    LP/PROPANE FIXED PIPING CONNECTION Connection: Operating Pressure: Supply Pressure: Standard Residential 1/2" ID gas service line - 1/2" NPT male with 3/8" flare adapter. 10.0" W.C.R LP/Propane. 11" to 14" W.C.R Nat. If in excess of 14" W.C.R, a step-clown regulator is required. Check with your local gas utility c[...]

  • Page 8

    LP/PROPAN E TAN K CON N ECTION Outdoor grills orificed for use with LP/Propane gas come equipped with a high capacity hose/regulator assembly for connection to a standard 20 lb. LP/Propane cylinder equipped with a Type 1, QCC-1 connector. Hose assembly must comply with Elastomeric Composite Hose and Couplings for Conducting Propane and Natural Gas,[...]

  • Page 9

    LEAK TESTING Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas tightness check must be performed at the installation clue to possible mishandling in shipment or excessive pressure unknowingly being applied to the unit. Periodically check the whole system for leaks, or immediately check if the[...]

  • Page 10

    INSTALLATION PROCEDURES FOR BUILT-IN INSTALLATION 1. A minimum of 6" (15.2 cm) from the sides, or a minimum of 8" (20.3 cm) from the right side if there is a rotisserie motor, and a minimum of 24" (61.0 cm) from the back must be maintained from the grill above the cookin 9 surface to adjacent vertical combustible construction. The gr[...]

  • Page 11

    ,, (15.2 cm) / / ._ A ,. n 0 0 _° o /, o°@ @0 / / / / MODEL Dim. A VGBQ300T/0302T 29 1/2" (74.9 cm) VGBQ300E VGIQ300T 29 1/2" (74.9 cm) VGIQ300E VGBQ410T/VGIQ410T 41 3/16" (104.6 cm) VGBQ410E/VGIQ410E VGBQ412T 41 3/16" (104.6 cm) VGBQ412E VGBQ530T/VGIQ530T 53 3/16" (135.1 cm) VGBQ530E/VGIQ530E VGBQ532T/VGIQ532T 53 3/16&qu[...]

  • Page 12

    CUTOUT DIMENSIONS Model Dim. B VGBQ300T/0302T 28 518" (72.7 cm) VGBQ300E VGIQ300T 28 5/8" (72.7 cm) VGIQ300E VGBQ410T/VGIQ410T 40 1/4" (102.2 cm) VGBQ410E/VGIQ410E VGBQ412T 40 1/4" (102.2 cm) VG BQ412E VGBQ530TNGIQ530T 52 1/4" (132.7 cm) VGBQ530E/VGIQ530E VGBQ532TNGIQ532T 52 1/4" (132.7 cm) VGBQ532E/VGIQ532E **Gas Inle[...]

  • Page 13

    BURNER ADJUSTMENT Each burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply may make it necessary to adjust the burners. The flames of the burners (except the rotisserie infrared burner) should be visually checked and compared with Fig. 1, Fig. 2, and Fig. 3. Flames should be blue and stable wi[...]

  • Page 14

    Fig. 3 SIDE BURNERS (If applicable) °O o _[ ° I -1_ Air Shutters / Orifice Fig. 4 FLAME HEIGHT SIDE BURNERS (If applicable) 3/8" (.95 cm) Fig. 6 FLAME HEIGHT TruSear BURN ER 1/4" (.64 cm) Fig. 5 FLAME HEIGHT INFRARED BURNER 1/4" (.64 cm) .-_ 14[...]

  • Page 15

    ROTISSERIE SYSTEM The rotisserie motor is attached to the mounting bracket located on the right side of the grill frame. The rotisserie motor must be electrically grounded in accordance with local codes The skewer for the rotisserie is assembled into the gear box assembly by placing the pointed end into the gear box, and resting the threaded end on[...]

  • Page 16