Vinotemp WINE-MATE WM1500 HTD-TE manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Vinotemp WINE-MATE WM1500 HTD-TE, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vinotemp WINE-MATE WM1500 HTD-TE one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Vinotemp WINE-MATE WM1500 HTD-TE. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Vinotemp WINE-MATE WM1500 HTD-TE should contain:
- informations concerning technical data of Vinotemp WINE-MATE WM1500 HTD-TE
- name of the manufacturer and a year of construction of the Vinotemp WINE-MATE WM1500 HTD-TE item
- rules of operation, control and maintenance of the Vinotemp WINE-MATE WM1500 HTD-TE item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vinotemp WINE-MATE WM1500 HTD-TE alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vinotemp WINE-MATE WM1500 HTD-TE, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vinotemp service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vinotemp WINE-MATE WM1500 HTD-TE.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Vinotemp WINE-MATE WM1500 HTD-TE item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    WINE-MATE Cooling Unit Use & Care Manual WM1500 HTD, HTD-TE WM2500 HTD, HTD-TE V V i i n n o o t t e e m m p p I I n n t t e e r r n n a a t t i i o o n n a a l l C C o o r r p p . . w w w w w w . . v v i i n n o o t t e e m m p p . . c c o o m m w w w w w w . . w w i i n n e e m m a a t t e e . . c c o o m m[...]

  • Page 2

    - 1 - Important Safety Information • DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY. • DO NOT USE A GROUND FAUL T INTERRUPTER (GFI). • A DEDICATED 20 AMP CIRCUIT IS REQUIRED.[...]

  • Page 3

    - 2 - TABLE OF CONTENTS Features & Specifications.…………………….……………..3 Installation Instruction………………………………………..5 Temperature Control & Humidity Adjustment……..……11 Care Guide……………………………………………………1 4 Troubleshooting………………………?[...]

  • Page 4

    - 3 - Features and Specifications • WM1500HTD, HTD-TE and WM2500HTD, HTD-TE cooling units are designed and used to provide a subtle temperature between 50~65 °F for suitable space at a normal environment. • The refrigerated space will mainta in humidity of 50~70% RH even when the environment becomes dry and humid. • These temperatures and hu[...]

  • Page 5

    - 4 - Fig. 1.2 DIMENSIONS (in) The dimensions and capacity are specified as follows: Model Exhaust CFM Capacity cu ft (55°F/75°F) Electrical Weight (lb) 1500htd Rear Exhaust 120 90 115V/60Hz/4A 55 1500htd-te Top Exha ust 120 90 115V/60Hz/4A 55 2500htd Rear Exhaust 180 200 115V/60Hz/5A 60 2500htd-te Top Exha ust 180 200 115V/60Hz/5A 60 NOTES: • [...]

  • Page 6

    - 5 - Installation Instruction NOTES: 1) DO NOT INSTALL ANY DUCTS ONTO THE SUPPLY, INTAKE AND EXHAUST. 2) MOUNTING BRACKETS, SCREWS, GASKETS AND OTHER SEAL MATERIALS ARE NOT INCLUDED. 1. Cabinet Location • Place the wine cabinet in a properly ventilated location. Otherwise, heat exhausted by the cooling unit will build up and it will not operate [...]

  • Page 7

    - 6 - • If top exhaust, cut another rectangular ope ning at the top of the cabinet to the length and width of the t op exhaust (see Fig.2.2 & 2.3). • Make 2 holes at the ceiling and insta ll the ¼” inside di ameter wood thread inserts (see Fig.2.1 & 2.3). • Place the gaskets (1/2” foam t ape) on the gasket lips (see Fig 2.4). •[...]

  • Page 8

    - 7 - Fig. 2.2 TOP EXHAUST CUTOUT Fig. 2.3 CUTOUT A ND HOLE DIMENSIONS[...]

  • Page 9

    - 8 - Fig. 2.4 GASKET AND SCREW INSERT Fig. 2.5 COOLING UNIT MOUNTING (EXPLODED)[...]

  • Page 10

    - 9 - Fig. 2.6 COOLING UNIT MOUNTING (COMPLETED) Fig. 2.7 COOLING UNIT MOUNTING (REAR EXHAUST) Fig. 2.8 COOLING UNIT MOUNTING (TOP EXHAUST)[...]

  • Page 11

    - 10 - Fig. 2.9 TOP EXHAUST GASKET 3. Electrical Cord • Because of potential safety hazards under a certain condition, we strongly recommend against the use of an extens ion cord. However, if you still elect to use an extension cord, it is absolutely necessary that it will be a UL LISTED 3-wire grounding type appliance extension cord having a 3- [...]

  • Page 12

    - 11 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantit y of bottles, temperature setting and surrounding temperature. • Allow 24 hours to stabilize th[...]

  • Page 13

    - 12 - 2.1 LED Functions LED MODE FUNCTION ON Compressor enabled Flashing Anti-short cycle enabled ON Defrost cycle enabled ON Fan enabled Flashing Fan delay after defrost enabled ON Alarm occurring ON Temperature measuring unit Flashing Programming mode 3) Alarm Signals 3.1 Code Description MESSAGE CAUSE FUNCTION P1 Temperature probe faulty Compre[...]

  • Page 14

    - 13 - 1. Press the SET + keys for 3 sec until the “ °C” or “°F” LED starts blinking, then release the keys. 2. Press again the SET + keys for more th an 7sec until the Pr2 label will be displayed, then release the keys. The first parameter Hy will be displayed. 3. Press up/down keys / to select the required parameter within 10 s ec. 4. P[...]

  • Page 15

    - 14 - Care Guide I. Component Identification Fig. 4.1 Exploded View[...]

  • Page 16

    - 15 - II. Condenser Coil Cleaning • The condenser coil is on the ambient air intake side of the cooling unit. • Clean the condenser coil regularly . Coil may need to be cleaned at least every 6 months. • Unplug the unit or disconnect power. • Use a condenser brush or a va cuum cleaner with an extended attachment to clean the coil w hen it [...]

  • Page 17

    - 16 - Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration servic e person, not is it comprehensive Complaint Possible Causes Response 1. Unit not running a. Power co rd u nplugged b. No power to unit c. Setting higher than ambient temperature d. Differential too high e. Incor[...]

  • Page 18

    - 17 - l. Failed components l. Chec k compressor wi ndings, start relay and overload protector 5. Unit running too long a. Improper room insulation & seal b. Exhaust restricted c. Room too large d. Ambient temperature higher > 90 ° F e. Dir ty C ondenser f. Improper condense r air flow a. Check for insulation, gasket and door opening b. Lea[...]

  • Page 19

    - 18 - rising high 11. Evaporator freezing up a. Evaporator air flow restricti on b. Not stopping due to air leak, high ambient temperature or low setting c. Low ambient temperature d. Bad thermostat or sensor e. Moisture in the system f. Refrigerant low or leaki ng g. Capillary tube blockage a. Check for fans & CFM b. Check for seal, door open[...]

  • Page 20

    - 19 - Wiring Diagram Fig. 6.1 WIRING DIAGRAM[...]

  • Page 21

    - 20 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com[...]

  • Page 22

    - 21 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and se rial numbers in the space provided: Model_____________ _________________________ __ _________________ Serial No._________________ ____________________ _________________ Attach your purchase receipt to this owner’s manual. 1. Limited Warranty VIN[...]

  • Page 23

    - 22 - is determined to be faulty and is within the twelve month warranty period VINOTEMP will, at its discret ion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect. 2. Limitation o[...]