Vizio DA-250F CU manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Vizio DA-250F CU, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vizio DA-250F CU one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Vizio DA-250F CU. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Vizio DA-250F CU should contain:
- informations concerning technical data of Vizio DA-250F CU
- name of the manufacturer and a year of construction of the Vizio DA-250F CU item
- rules of operation, control and maintenance of the Vizio DA-250F CU item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vizio DA-250F CU alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vizio DA-250F CU, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vizio service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vizio DA-250F CU.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Vizio DA-250F CU item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MUL TICHANNEL POWER AMPLIFIERS DA-250F CU DA-250FH CU Thank you for purchasing TOA's Multichannel Power Amplifier. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment. Note: The figure shows the DA-250F. OPERA TING INSTRUCTIONS An all-pole mains switch with a contact separation of at least[...]

  • Page 2

    2 T ABLE OF CONTENTS 1. IMPORT ANT SAFETY INSTRUCTIONS .................................................... 3 2. SAFETY PRECAUTIONS ............................................................................... 4 3. GENERAL DESCRIPTION ............................................................................. 6 4. FEA TURES ....................[...]

  • Page 3

    3 1. IMPORT ANT SAFETY INSTRUCTIONS • Read these instructions. • Keep these instructions. • Heed all warnings. • Follow all instructions. • Do not use this apparatus near water. • Clean only with dry cloth. • Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. • Do not install near[...]

  • Page 4

    4 When Installing the Unit • Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock. • Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock. • Do not cut, [...]

  • Page 5

    5 • When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. When removing the power cord, be sure to hold its plug to pull. • Avoid installing the unit in humid or dusty locations, in l[...]

  • Page 6

    6 3. GENERAL DESCRIPTION TOA's DA-250F and DA-250FH Multichannel Power Amplifiers feature high power handling capabilities and durability. The DA-250F is configured with 250 W x 4 channels (4 Ω output) and 170 W x 4 channels (8 Ω output), and the DA-250FH features a 250 W x 4 channels (70 V line, 19.6 Ω output) configuration. Besides, each [...]

  • Page 7

    Rack mounting screws are not supplied with the unit. Be sure to use the screws with a diameter of over 5 mm (0.2") and length of over 12 mm (0.47") to mount the unit. Failure to do so may cause personal injury. CAUTION 6. INST ALLA TION PRECAUTIONS 7 • The supplied power supply cord is designed for exclusive use with this unit. Never us[...]

  • Page 8

    8 1. Power switch [ ON / OFF] Turning this switch on causes the amplifier to function, and turning it off causes the amplifier to cease function. Note: The unit is not completely disconnected from the power supply even if this Power switch is turned off. 2. Power indicator [POWER] Lights blue when the Power switch (1) is turned on. 3. Input level c[...]

  • Page 9

    9 [Rear] 6 7 8 DA-250F 9 9 10 11 6 7 8 DA-250FH 9 9 10 11 6. AC inlet Connect the supplied power cord to this inlet. The socket-outlet shall be installed near the equipment and the plug (disconnecting device) shall be easily accessible. 7. Functional ground terminal [SIGNAL GND] Hum noise may be generated when external equipment is connected to the[...]

  • Page 10

    10 Step 1. Turn off this unit's Power switch. Step 2. Set the BRIDGE ON/OFF switches and CH 1 mode ON/OFF switch. Step 3. Connect the sound source equipment to the Input terminals. Note: Refer to p. 12 for the removable terminal plug connection. Step 4. Connect speakers to the Speaker output terminals. 4-1. Unscrew the output terminal cover. 4[...]

  • Page 11

    11 CH4 - + CH3 - + CH2 - + CH1 - + [1 input - 4 outputs] CH1 CH1 CH2 CH3 CH4 – + – + – + – + Switch BRIDGE 1 BRIDGE 2 CH 1 mode OFF OFF ON Setting Speaker output terminals 4 – 8 Ω 4 – 8 Ω 4 – 8 Ω 4 – 8 Ω 19.6 Ω 19.6 Ω 19.6 Ω 19.6 Ω DA-250F DA-250FH BRIDGE 1 BRIDGE 2 [2 inputs - 2 outputs] CH1 CH3 CH1 CH2 CH3 CH4 Speaker outp[...]

  • Page 12

    12 Connector connections Step 1. Loosen the terminal screw, then insert the cable. Step 2. Retighten the terminal screw. (Pull on the cable to ensure it is securely connected.) Tip Recommended slotted screwdriver type: Screwdriver with blade that is 3 mm (0.12") in width T ightens Loosens T erminal screw Slotted screwdriver Shielded cable Remo[...]

  • Page 13

    13 10. INPUT SENSITIVITY AND HIGH-P ASS FIL TER ON/OFF SETTINGS The Input sensitivity can be set to +4 dB (factory-preset) or –10 dB for each channel. Besides, only the DA-250FH employs the High-pass filter on each channel, which can be set to "ON" or "OFF." Step 1. Remove this unit's power plug from an AC outlet. Step 2.[...]

  • Page 14

    14 1 1. PROTECTION OPERA TION LIST Failure Protection Operation Indicator Remedy Recovery Overcurrent due to overload Current limiter activated when impedance drops below the specified value. Peak indicator lights. Remove overload. Connecting a correct load automatically restores normal operation. Short circuit Current limiter activated. Load is di[...]

  • Page 15

    15 13. CLEANING THE FIL TER Step 1. Turn off this unit's Power switch. Step 2. Remove the ventilation panel as shown in the figure. Step 3. Detach the filter inside the ventilation panel. Step 4. Clear the filter of dust. Step 5. Replace the filter and ventilation panel. Ventilation Panel 2 3 Filter Ventilation Panel Detach the panel by pressi[...]

  • Page 16

    16 H C CH 1 INPUT E H C CH 2 INPUT E Current Limiter Short Detector Protection Circuit OUTPUT 1 relay CH 1 OUTPUT CH 2 OUTPUT +4 dB - 10 dB CH 1 sensitivity selection jumper (+4 dB/ - 10 dB) CH 1 input level control +4 dB - 10 dB CH 2 sensitivity selection jumper (+4 dB/ - 10 dB) CH 2 input level control ON OFF BRIDGE 1 ON/OFF switch + - BRIDGE 1 O[...]

  • Page 17

    17 14.2. DA-250FH OFF ON CH 2 HPF ON/OFF jumper HPF 50 Hz OFF ON CH 3 HPF ON/OFF jumper HPF 50 Hz OFF ON CH 4 HPF ON/OFF jumper HPF 50 Hz H C CH 1 INPUT E H C CH 2 INPUT E Current Limiter Short Detector Protection Circuit OUTPUT 1 relay CH 1 OUTPUT CH 2 OUTPUT +4 dB - 10 dB CH 1 sensitivity selection jumper (+4 dB/ - 10 dB) CH 1 input level control[...]

  • Page 18

    18 15. DIMENSIONAL DIAGRAM Unit: mm (inches) 401.8 (15.82) 371 (14.61) 22.5 (0.89) 482 (18.98) 465 (18.31) 442 (17.4) 31.8 (1.25) 44 (1.73)[...]

  • Page 19

    19 * 0 dB = 0.775 V Note: The design and specifications are subject to change without notice for improvement. Power cord (2 m or 6.56 ft) .................................................. 1 Removable terminal plug (3 pins) ........................................ 4 Tamper-proof cap ................................................................ 4[...]

  • Page 20

    133-22-027-0B URL: http://www.toa.jp/ * 0 dB = 0.775 V Note: The design and specifications are subject to change without notice for improvement. Power cord (2 m or 6.56 ft) .................................................. 1 Removable terminal plug (3 pins) ........................................ 4 Tamper-proof cap ...............................[...]