Go to page of
Similar user manuals
-
Fryer
Vulcan-Hart 2G6BDF
26 pages 0.97 mb -
Fryer
Vulcan-Hart CCF-18
36 pages 10.75 mb -
Fryer
Vulcan-Hart 3GR65DF ML-136428
27 pages 1.74 mb -
Fryer
Vulcan-Hart 1GR35M ML-136407
24 pages 1.17 mb -
Fryer
Vulcan-Hart 2G4BDF
26 pages 0.97 mb -
Fryer
Vulcan-Hart ML-13
24 pages 1.27 mb -
Fryer
Vulcan-Hart 3GR85DF ML-136429
27 pages 1.74 mb -
Fryer
Vulcan-Hart MEF24A
12 pages 0.22 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Vulcan-Hart 2GR45CF ML-136431, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vulcan-Hart 2GR45CF ML-136431 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Vulcan-Hart 2GR45CF ML-136431. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Vulcan-Hart 2GR45CF ML-136431 should contain:
- informations concerning technical data of Vulcan-Hart 2GR45CF ML-136431
- name of the manufacturer and a year of construction of the Vulcan-Hart 2GR45CF ML-136431 item
- rules of operation, control and maintenance of the Vulcan-Hart 2GR45CF ML-136431 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vulcan-Hart 2GR45CF ML-136431 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vulcan-Hart 2GR45CF ML-136431, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vulcan-Hart service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vulcan-Hart 2GR45CF ML-136431.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Vulcan-Hart 2GR45CF ML-136431 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INSTALLATION & OPERATIONAL MANUAL GRD & GRC SERIES GAS FRYERS With KleenScreen PLUS ® Filtration Systems M O D E L S : 1 G R 4 5 D M L - 1 3 6 4 1 1 1 G R 4 5 C M L - 1 3 6 4 1 4 1 G R 6 5 D M L - 1 3 6 4 1 2 1 G R 6 5 C M L - 1 3 6 4 1 5 1 G R 8 5 D M L - 1 3 6 4 1 3 1 G R 8 5 C M L - 1 3 6 4 1 6 1 G R 4 5 D F M L - 1 3 6 7 7 8 1 G R 4 5 [...]
-
Page 2
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE [...]
-
Page 3
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY……………………………… ………. 2 INTRODUCTION…………………… …………………………………… … 4 GENERAL…………………………… ……………………………… 4 ORDERING PARTS…?[...]
-
Page 4
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance. Before installing the fryer, thoroughly read th is manual and carefully fo llow all instructio[...]
-
Page 5
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -5- INSTALLATION Do not use the door or its handle to lift the fryer. Before installing the fryer, veri fy that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel. Make sure the fryer is con[...]
-
Page 6
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -6- CODES AND STANDARDS The fryer must be insta lled in accordance with: In the United States: State and local codes, or in the absence of local codes, with: National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may be obtained from The American Gas Associa[...]
-
Page 7
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -7- FLUE CONNECTION Make the flue connection as follows: Comply with Vapor Removal from Cooking Equipment , ANSI-NFPA Standard #96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Locate the fryer under a hood [...]
-
Page 8
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -8- After piping has been checked for leaks, fully purge gas pipes to remove air. GAS PRESSURES (ALL MODELS): The gas pressure should be set at 4” W.C. (W ater Column) (0.8 kPa) for natural gas and 10” W.C. (2.75 kPa) for propane gas. If incoming pressure exceeds ½ PSI (3.45 [...]
-
Page 9
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -9- In Australia, use only the caster suppl ied by the manufacturer for the fryer device. The fryer must be installed using a hose assembly restraining device to limit the movement of the appliance in accordance with AS1869. The fryer must be installed with a connector (no[...]
-
Page 10
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -10- BEFORE FIRST USE Cleaning New units are wiped down at the fa ctory to remove an y visible signs of dirt, oil, grease, etc. remaining from th e manufacturing process. Before any food preparation, thoroughly wash the protective oil from all surface parts and the tank interior w[...]
-
Page 11
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -11- BASIC FRYING INSTRUCTION Set the desired temperature and allow shorte ning to heat up to t hat temperature. Fry items that are the same size to ensure equal doneness. Drain or wipe dry raw or wet foods to minimize splatter when lowering into hot shortening. Ad[...]
-
Page 12
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -12- TURNING ON THE FRYER Open the door to the fryer. Turn t he power switch to the on position. Set temperature by turning the knob to the desired temperat ures. The burners will light automatically. The burners will cycle on and off, mainta ining the set temperature.[...]
-
Page 13
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -13- Programming the Solid State Control[...]
-
Page 14
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -14- Programming the Computer Control[...]
-
Page 15
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -15- DRAINING THE TANK 1. Turn off fryer. 2. Insert the drain extension into the drain valve. Tighten only hand tight. 3. Direct the drain spout into the container that you want to drain the shortening into. 4. Open the drain valve. The oil will drain in to the container. When the[...]
-
Page 16
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -16- 7. Press the TEMP button again and the gas burners will heat the so lution. Bring the solution to a simmer only. A llow to stand for a few minutes. 8. Turn OFF the power to the fryer. Dr ain the tank according to DRAINING THE TANK. Rinse thoroughly with clear, hot wa ter. All[...]
-
Page 17
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -17- KleenScreen Plus ® Filtration System Installation and Operational Manual for “DF” and “CF” Models GRD/CF and 2XGD/CF Models 2GR45DF Shown 2XG45DF Shown GAS KleenScreen PLUS® Models: 1GR45DF ML-136778 1GR45CF ML-136791 1GR65DF ML-136789 1GR65CF ML-136792 1GR85DF ML-1[...]
-
Page 18
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -18- Filtering Instructions for KleenScreen PLUS ® Fryers General The KleenScreen PLUS ® filtration system filters t he oil as it is pumped back into its’ respective tank(s). Only one tank can be dr ained and filtered at a time. Under no circumstances should both tanks be drai[...]
-
Page 19
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -19- Fully assembled filter screen assembly: F i g . 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig. 3 Micro-Filtration Fabric Envelope Assembly: Same Suction Tube F a b r i c E n v e l o p e I n s e r t (Different from Screen Assembly) Fa[...]
-
Page 20
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -20- INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS ® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RA TE WE RECOMME ND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE). Step 1 Discard all oil from the filter vessel, (se[...]
-
Page 21
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -21- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank. Never run water or boil out solution thr ough fil[...]
-
Page 22
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -22- Filtering Instructions for KleenScreen PLUS ® Fryers with Solid State Controls[...]
-
Page 23
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -23- Filtering Instructions for KleenScreen PLUS ® Fryers with Computer Controls[...]
-
Page 24
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -24- FILTERING TIP: Open the filtering drawer approximately 1” to allow any oil in the re turn line to run back into the filter pan. This will take about 30 seconds to complete. Then open the drawer completely to clean filter components. REMOVING EXCESS DEBRIS FROM THE SCREEN FI[...]
-
Page 25
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -25- BOIL OUT PROCEDURE: Use the Boil Out By-Pass™ drai n extension allowing the boil out solution to exit the fry tank without using the filtering system. Do not allow water to run through the motor / pump. Drain the boil out solution into a bucket or place a hose on the end of[...]
-
Page 26
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -26- MAINTENANCE Hot oil and hot parts can cause burns. Use care when operating, clean ing, and servicing the fryer. Spilling hot fryer com pound can cause severe burns. Do not move fryer without draining all frying compound from the ta nk. FLUE VENT INSPECTION When the fryer is c[...]
-
Page 27
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. G (May 2009) -27- OPEN PROBE – If an open probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator butt ons are disabled. The digital control displays the following message: “D” Solid State – OPEN PROBE “C” Computer – PROBE OPEN SH[...]