Go to page of
Similar user manuals
-
Griddle
Vulcan-Hart ML-135309-924RX
14 pages 1.91 mb -
Griddle
Vulcan-Hart 972A ML-52608
12 pages 0.37 mb -
Griddle
Vulcan-Hart ML-135310-936RX
14 pages 1.91 mb -
Griddle
Vulcan-Hart MSA60 ASA60
48 pages 1.54 mb -
Griddle
Vulcan-Hart RRE36D
4 pages 0.64 mb -
Griddle
Vulcan-Hart ML135341-00048
22 pages 2.49 mb -
Griddle
Vulcan-Hart ML-135311-948RX
14 pages 1.91 mb -
Griddle
Vulcan-Hart MSA72
8 pages 0.87 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Vulcan-Hart MSA48 ASA48, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vulcan-Hart MSA48 ASA48 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Vulcan-Hart MSA48 ASA48. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Vulcan-Hart MSA48 ASA48 should contain:
- informations concerning technical data of Vulcan-Hart MSA48 ASA48
- name of the manufacturer and a year of construction of the Vulcan-Hart MSA48 ASA48 item
- rules of operation, control and maintenance of the Vulcan-Hart MSA48 ASA48 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vulcan-Hart MSA48 ASA48 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vulcan-Hart MSA48 ASA48, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vulcan-Hart service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vulcan-Hart MSA48 ASA48.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Vulcan-Hart MSA48 ASA48 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
ITW Food Equipment Group, LLC 3600 North Point Blvd. Baltimore, MD 21222 RETAIN THIS MANUAL FOR FUTURE USE FORM F-38315 (rev. 08-10) INSTALLATION & OPERATION MANUAL HEAVY DUTY GAS GRIDDLES MODELS 924RX 936RX 948RX 960RX 972RX MSA24 ASA24 MSA36 ASA36 MSA48 ASA48 MSA60 ASA60 MSA72 ASA72 AGM24 AGM36 AGM48 AGM60 AGM72 948RX AGM48 MSA48[...]
-
Page 2
- 2 - IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOU LD PERFORM THE IN ITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION TH E INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETE CTED. THIS INFORMATION CAN BE OBT[...]
-
Page 3
- 3 - TABLE OF CONTENTS GENERAL………………………… …………………………………… …………………………...…...… Specifications…………………………………………… ………………………………………..... .... INSTALLATION………………… …………………………… …………[...]
-
Page 4
- 4 - INSTALLATION, OPERATION AND CARE OF HEAVY DUTY GAS GRIDDLES GENERAL Heavy Duty Gas Griddles are produce d with quality workmanship and mater ials. Proper installation, usage and maintenance of your griddle will result in many years of satisfa ctory per formance. Thoroughly read this entire ma nual and car efully follow all o f the instru ctio[...]
-
Page 5
- 5 - Do not pe rmit air to b low directl y at the griddl e. Avoid o pen windows next to the griddl e wherever possible. Avo id wall-type fans which create air cross-cu rrents within the roo m. This griddle is Design Certified f or installation on a non-combusti ble counter wi th 4” legs, or combustible floor with 25 ” high stand. INSTALLATION [...]
-
Page 6
- 6 - If disconnectio n of the restraint i s necessary, turn off the gas supply before disconnecting. Reco nnect the restraint p rior to turning the gas supply on an d returning the griddl e to its insta llation position. Casters are only sup plied on a griddle stand. If th e griddle is moved for any reason th e griddle shou ld be re-levele d (see [...]
-
Page 7
- 7 - GAS PRESSURE REGULATO R INSTALLATION A gas pressure regulator is supp lied with the grid dle and must be instal led. Install the regulator as close to the gr iddle on the gas supply line as possib le. Make sure that the arrow on the und erside of the regulator is or iented in the dir ection of gas f low to the griddle (Fig. 2) and the regul a[...]
-
Page 8
- 8 - OPERATION The griddle a nd its parts ar e hot. Use car e when oper ating, clea ning or servicin g the griddle. BEFORE FIRST USE Remove all packing mater ial and protect ive plastic fr om the surfaces of the unit. Bef ore leaving the fact ory the griddle is co ated with veget able oil as a rust inh ibitor. Remove this film when the grid dle pl[...]
-
Page 9
- 9 - This model feature s an electric ignition system that is controlled by a momentary power switch. The power switch turn s the electri c ignition syste m off and on onl y and will onl y supply powe r to the ignit ers when held down in the ON po sition. The bu rners and pil ots will continue to work with power switch in the OFF position until th[...]
-
Page 10
- 10 - CONTROLS – MSA AND ASA MODELS This model fe atures a standin g pilot that must be manually lit wit h an outside ignition source (su ch as a lit ta per, etc). The pilo t is monitore d by a t hermocouple an d pilot safety valve. If the pilot goes o ut, the safety valve will sh ut-off the ga s supply to the pilot and main burners. There is on[...]
-
Page 11
- 11 - CONTROLS – AGM MODELS The model is e quipped with standing pilo ts. Gas will flo w from the pilots as soon as the main gas supply to th e unit is turned on. The pilot s are lit with the us e of an outside ignition source (such as a lit taper, etc) . There is one p ilot for every two bu rners excep t on the 36” and 60 ” models. The 36?[...]
-
Page 12
- 12 - PILOT LIGHTING PROCEDURE – 900RX MODELS 1. Turn the griddle shut-off valve to the OFF position (See Fig.6 on page 9). Wait 5 minutes to allow any gas that may have accumulated in the burner compartment to escape. 2. Turn the griddle shut-off valve to the ON position (See Fig. 5 on page 9). 3. Push and hold the power switch in the ON positi[...]
-
Page 13
- 13 - PILOT LIGHTING PROCEDURE- MSA AND ASA MODELS 1. Turn the main gas shut-off valve to the OFF position. Wait 5 minutes to allow any gas that may have accumulated in the burner compartment to escape. 2. Turn the main gas shut-off valve ON. 3. Depress and hold the safety valve button while lighting the corresponding pilot. Y ou will have to reac[...]
-
Page 14
- 14 - PILOT LIGHTING PROCEDURE – AGM MODELS 1. Turn the main gas shut-off valve and all burner control knobs to the OFF position. Wait 5 minutes to allow any gas that may have accumulated in the burner compartment to escape. 2. Turn the main gas shut-off valve ON. 3. While viewing through the pilot sight hole, you will have to reach under the fr[...]
-
Page 15
- 15 - USING THE GRIDDLE To preheat, turn th e burners on about 20-25 min utes before cookin g. A uniform and sy stematic ap proach to lo ading the gr iddle will pro duce the most co nsistent product re sults. The griddl e plate is steel, but the surface is relatively so ft and can be scored or de nted by careless use of a sp atula or scraper. Be c[...]
-
Page 16
- 16 - CLEANING THE GRIDDLE Empty the gre ase drawer as needed thro ughout the d ay and regul arly clean at least once daily. Clean the grid dle regularly. A clean grid dle alway s looks better, last s longer and perform s better. To produce evenly cooked, perf ectly browned g riddle produc ts keep the gr iddle plate clean and free of carbonized gr[...]
-
Page 17
- 17 - ADJUSTMENTS CALIBRATION-900RX AND M SA MODELS 1. Each thermostat co ntrols a 12” zone of the griddle. Usin g a Surface P robe temp erature measurement de vice, observe the te mperatures at the center points of t he cooking zon es. These points are lo cated by starting 6” fr om the side splash (left or right) and every 12 ” across the w[...]
-
Page 18
- 18 - LEVELING The griddl e must be level (side-to-side and front-t o-back) during op eration to e nsure proper perfo rmance. Improper leveling can result in uneven temperat ure distribution, co ld spots, and po ssibly damage el ectrical comp onents. 1. Place a level on the g riddle. 2. Adjust legs by t urning the bu llet feet a t the bott om of e[...]
-
Page 19
- 19 - SHUTDOWN OF GRIDDLE – MSA AND ASA MODELS 1. Turn ther mostats to the OFF positi on to cut off burners. 2. The pil ots will remain lit a nd monitore d by the safe ty valve as long as the main gas supply is on. SHUTDOWN OF GRIDDLE WITH STANDI NG PILOT SYSTEM – AGM MODELS 1. Turn bu rner control kn obs to the O FF position to cut of f burne[...]
-
Page 20
- 20 - MAINTENANCE The griddle a nd its parts ar e hot. Use car e when oper ating, clea ning or servicin g the griddle. LUBRICATION All valves mu st be checke d and lubricate d periodically. Chec k with your servi ce agency for details. VENT Daily, wh en the grid dle is cool, c heck the flu e and clear an y obstructions. SERVICE AND PARTS INFORMATI[...]
-
Page 21
- 21 - TROUBLESHOOTIN G PROBLEM POSSIBLE CAUSES Heat does n ot come on when the th ermostat or burner valve is turne d on 1. Problem with thermostat or burner valve. (Call f or service) 2. Pilot burner not lit. 3. Griddle shut-o ff valve not in ON posit ion. 4. Low gas pressure. (Call for service) Pilot burner will no t light 1. Griddle shut-o ff v[...]
-
Page 22
- 22 - ACCESSORY INSTALLATION The griddle a nd its parts ar e hot. Use car e when oper ating, clea ning or servicin g the griddle. 1 SIDE VIEW 2[...]
-
Page 23
- 23 - SIDE VIEW FRONT VIEW 4 3[...]
-
Page 24
- 24 - NOTES[...]
-
Page 25
Groupe ITW Équipement a limentaire, LLC 3600 North Point Blvd. Baltimore, MD 21222 DOCUMENT À CONSERVER EN CAS DE BESOIN FORMULAIRE F-38315 (r ev. 08-10) MANUEL D’INSTALLATION ET D’EMPLOI PLAQUES CHAUFFANTES À FONCTION ÉLEVÉE MODELS 924RX 936RX 948RX 960RX 972RX MSA24 ASA24 MSA36 ASA36 MSA48 ASA48 MSA60 ASA60 MSA72 ASA72 AGM24 AGM36 AGM48 [...]
-
Page 26
- 2 - MESURES DE SÉCURITÉ IMPORTANTES CE MANUEL A ÉTÉ PRÉPARÉ À L’INTE NTION D’UN PERSONNEL QUALIFIÉ ET AUTORISÉ À INSTALLER DES APPAREIL S FONCTIONNANT AU GAZ ET À EFFECTUER LE DÉMARRAGE INITIAL CHE Z LE CLIENT DE MÊME QUE LE RÉGLAGE DES APPAREILS CONCERNÉS DANS CE MANUEL. AFFICHER À UN ENDROIT VISIBLE LES PR EMIERS SOINS À AD[...]
-
Page 27
- 3 - TABLE DES MATIÈRES GÉNÉRAL………………………… …………………………………… …………………………...…...… Caractéristiques…………… ……………………………………… ………………………………...... INSTALLATION………………… …………………………… ……?[...]
-
Page 28
- 4 - INSTALLATION, FONCTIONNEMENT ET ENTRETIEN PLAQUES À FRIRE AU GA Z À SERVICE INTENSE GÉNÉRALITÉS Les plaques à fr ire au gaz à service inte nse sont fabriquée s avec le plus grand soin et à partir des meil leurs matériaux. Le ur installation, u tilisation et ent retien appropriés permettent d’en ob tenir un rendement op timal pend[...]
-
Page 29
- 5 - Veiller à ce que les ventilateurs ne soufflent pas directement sur la plaque à frire et, dans la mesure du possible, ne pas ouvrir les fenêtres à proximité de l’appareil ni utiliser des ventilateurs muraux qui produisent des courants d’air. Cette plaque à frire a été conçue en fonction d’une installatio n sur un comptoir incomb[...]
-
Page 30
- 6 - Si le débranchement du dispositif de retenue est nécessaire, éteindre l’alimentation en gaz avant le débranchement. Rattacher le dispositif de retenue av ant de rétablir l’alimentation en gaz et de remettre l’appareil à la position d’installation. Les roulet tes sont fo urnies seulemen t sur le support de la plaque à fr ire. Si[...]
-
Page 31
- 7 - PRESSION DU GAZ ET INSTALLATION D’ UN RÉGULATEUR Il faut installer le régulateur de pression du gaz f ourni avec la plaque chauffante Installer le régulateur aussi près que possible de la plaque à frire, sur la conduite d e gaz. S’assurer que la flèche sur la face intérieure du régulateur pointe vers le débit de gaz allant à la [...]
-
Page 32
- 8 - FONCTIONNEMENT ! AVERTISSEMENT La plaque à frire et ses composants sont chauds. Exercer une extrême prudence lors de l’exploitation, du nettoyage et de l’entretien de cet appareil. AVANT UNE PREMIÈRE UTILISAT ION Retirez to ut le matérie l d’emballage e t la protection en plastique des surfa ces de l’appareil. Avant de quitte r l?[...]
-
Page 33
- 9 - Ce modèle compo rte un système d'allu mage électrique q ui est contrôlé par un interrupteur d ’alimentation à rappel. L’in terrupteur d’ali mentation o uvre et ferme seulemen t le système d’a llumage électr ique et fournit seu lement l’alime ntation aux allumeurs lorsqu’il est maintenu ouver t. Les brûleurs et les ve[...]
-
Page 34
- 10 - COMMANDES – MODÈLES MSA ET AS A Ce modèle comport e une veilleuse per manente qui doit être allumé e manuellement à l’aide d’une source d'in flammation exté rieure (tell e qu’une tige pour allumer les bougies, etc.). L a veilleuse es t contrôlée par un thermocouple et par une soupape de s ûreté. Si la veill euse s’é[...]
-
Page 35
- 11 - COMMANDES – MODÈLES AGM L’appareil est muni de ve illeuses d’allumage perman entes non contrôlé es. Le gaz circulera à p artir des veilleus es dès que l’aliment ation principale en gaz de l’appa reil est ouverte. Les vei lleuses sont allu mées à l’aide d’u ne source d'inflammati on extérieure (telle qu’une tige p[...]
-
Page 36
- 12 - PROCÉDURE D’ALLUMAGE DE LA VEILLEUSE – MODÈLES 900RX 1. Fermez le robinet d’arrêt de la plaque chauffante (Voir Fig. 6 à la page 9). Attendez 5 minutes pour permettre au gaz accumulé dans le compartiment des brûleurs de s’échapper. 2. Ouvrez le robinet d’arrêt de la plaque chauffante (Voir Fig. 5 à la page 9). 3. Poussez e[...]
-
Page 37
- 13 - VUE EN COUPE BRÛLEUR DE VEILLEUSE FENTE DE LA VEILLEUSE 12” (305 mm) BOUTON DE LA SOUPAPE DE SÛRETÉ DE LA VEILLEUSE TROU D’OBSERVATION DE LA VEILLEUSE Fig. 12 PROCÉDURE D’ALLUMAGE DE LA VEILLEUSE – MODÈLES MSA E T ASA 1. Fermez le robinet d’arrêt principal du gaz. A ttendez 5 minutes pour permettre à tout gaz accumulé dans [...]
-
Page 38
- 14 - VUE EN COUPE Fig. 13 BRÛLEUR DE VEILLEUSE FENTE DE LA VEILLEUSE TROU D’OBSERVATION DE LA VEILLEUSE 12” (305 mm) bouton de commande des brûleurs PROCÉDURE D’ALLUMAGE DE LA VEILLEUSE – MODÈLES AGM 1. Fermez le robinet d’arrêt principal du gaz. Attendez 5 minutes pour per mettre à tout gaz accumulé dans le compartiment des brû[...]
-
Page 39
- 15 - UTILISATION DE LA PLAQUE À FRIRE Allumer les brûleurs de 20 à 25 minutes avant la cuisson pour le préchauffage de la plaque. Pour obtenir des résultats des plus constants, il est important de placer les aliments dans la plaq ue de façon uniforme et systématique. La plaque à frire est en acier, mais la surface est relativement fragile[...]
-
Page 40
- 16 - NETTOYAGE DE LA PLAQUE À FRIRE Vider le tiroir de propreté au besoin durant le jour et régulièrement au moins une fois par jour. Nettoyer la plaque à frire régulièrement. Une plaque propre a meilleure apparence, dure plus longtemps et donne de meilleurs résultats. Pour obtenir des résultats de cuisson uniformes et des produits parfa[...]
-
Page 41
- 17 - RÉGLAGES ÉTALONNAGE-MODÈLES 900RX ET MSA 1 . Chaque thermostat commande une zone de 305 m m (12 po) de la plaque à frire. Utiliser un dispositif de mesurage de la température adéquat pour observer les températures à des points centraux des zones de cuisson. En partant de 152 mm (6 po) d’un côté ou de l’autre de la plaque et à [...]
-
Page 42
- 18 - NIVELAGE Niveler la plaque à frire (d’un côté à l’autre et d’ava nt en arrière) pour obtenir un meilleur rendement de l’ap pareil, faute de quoi la distribu tion de tempér ature ne sera pas ég ale, certains en droits seront plus froid et les co mposants él ectriques po urraient poss iblement être endommagé s. 1. Placer un n[...]
-
Page 43
- 19 - FERMETURE DE LA PLAQUE CHAUFFA NTE – MODÈLES MSA ET ASA 1. Fermez l es thermostats pour éteindre les brûleu rs. 2. Les veille uses resteront all umées et contrôl ées par la soupa pe de sûreté a ussi longtemps que l’a limentation principaleen gaz est ou verte. FERMETURE DE LA PLAQUE CHAUFFANTE AVEC SYSTÈME DE VEILLEUSES PERMANENT[...]
-
Page 44
- 20 - ENTRETIEN ! AVERTISSEMENT La plaque à frire et ses composants sont chauds. Exercer une extrême prudence lors de l’exploitation, du nettoyage et de l’entretien de cet appareil. LUBRIFICATION On doit vérifier et lubrifier toutes les soupape s régulièrement. Cont actez votre agenc e de servicepour de p lus amples déta ils. CONDUIT D?[...]
-
Page 45
- 21 - DÉPANNAGE PROBLÈME CAUSES POSSIBLES Aucune chaleur lorsqu’on ouvre le thermostat 1. Problème de thermostat. (Communiquer avec le ser vice de l’entretien). 2. Le brûleur de la veilleuse ne reste pas allu mé. (Communiquer avec le service de l’entretien). 3. Le robinet d ’arrêt de la plaque chau ffante n’es t pas ouvert . 4. La [...]
-
Page 46
- 22 - INSTALLATION DE COMPLICE ! AVERTISSEMENT La plaque à frire et ses composants sont chauds. Exercer une extrême prudence lors de l’exploitation, du nettoyage et de l’entretien de cet appareil. 1 2 PROFIL [...]
-
Page 47
- 23 - PROFIL VUE DE DEVANT 3 4[...]
-
Page 48
- 24 - REMARQUES[...]