Warwick SUB III manual

1
2
3
4
5
6
7

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Warwick SUB III, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Warwick SUB III one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Warwick SUB III. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Warwick SUB III should contain:
- informations concerning technical data of Warwick SUB III
- name of the manufacturer and a year of construction of the Warwick SUB III item
- rules of operation, control and maintenance of the Warwick SUB III item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Warwick SUB III alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Warwick SUB III, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Warwick service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Warwick SUB III.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Warwick SUB III item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OFFICIAL W ARWICK AMP OWNER MANUAL ENGLISH SUB III[...]

  • Page 2

    SAFETY HINTS - Read these instructions - Keep these instructions - Heed all warnings - Follow these instructions Caution: T o reduce the risk of electrical shock, do not remove the cover . Or expose this appliance to rain or moisture. No user serviceable parts inside; refer serving to qualified personnel. Apparatus shall not be exposed to dripping [...]

  • Page 3

    3 RECOMMENDA TIONS The following recommendations are designed to ensure that the device always functions reliably: • Never open the casing! T o do so would expose you to the risk of an electric shock. Should repairs prove necessar y , leave them to qualified service personnel. • Avoid dust and high moisture levels, direct sunlight and extremely[...]

  • Page 4

    4 PROTECTIVE CIRCUITS Y our new Warwick amplifier is equipped with a series of circuits to prevent it from destruction in case of inadequate ope- rating conditions: Power -up delay: When the unit is switched on, the SPEAKER OUT sockets are activated with a slight delay to protect the loudspeakers. Short-circuit: In the event of a short-circuit at t[...]

  • Page 5

    5 ELEMENTS LINE OUT socket allows to connect additional power amplifiers or active cabinets. LINE IN socket to connect the (post master prefered) LINE OUT of an amplifier or preamplifier . INPUT - 3 DB P AD switch to adjust the loudness (not pressed -3dB, depressed 0dB) MAINS IN AC T erminal with integrated fuse compartment for connecting the ampli[...]

  • Page 6

    6 TECHNICAL DA T A T ake 12 Sweet 15 CL CCL SUB III Input 25 mV 25 mV 25 mV 25 mV 25 mV Preamp CH 1 transistor active controlled transistor active controlled transistor active controlled transistor active controlled none Preamp CH 2 n/a n/a n/a n/a n/a Poweramp fan cooled (non permanent) fan cooled (non permanent) fan cooled (non permanent) fan coo[...]

  • Page 7

    Headquarters: Warwick GmbH&Co.Music Equipment KG • Gewerbegebiet Wohlhausen • 08258 Markneukirchen/Germany • E-Mail: info@warwick.de Branch China: Warwick Music Equipment (Shanghai) Ltd., Co.•Shanghai Waigaoqiao Free T rade Zone • Shanghai 200131/P .R.China • E-Mail: info@war wick.cn Branch UK: Warwick Music Equipment T rading (Manc[...]