Go to page of
Similar user manuals
-
Network Card
Watlow Electric RUI/Gateway
20 pages 0.32 mb -
Thermostat
Watlow Electric Series 142
8 pages 0.24 mb -
Network Card
Watlow Electric Integrated Controller User Manual Rev C EZ-ZONE PM
80 pages 3.42 mb -
Network Card
Watlow Electric Ramping and Profiling Microprocessor-Based Control SERIES 1500
90 pages 0.94 mb -
Electric Heater
Watlow Electric FREEZE-SAFE
1 pages 3.57 mb -
Electric Heater
Watlow Electric 1220
2 pages 0.06 mb -
Electric Heater
Watlow Electric 397
1 pages 0.04 mb -
Switch
Watlow Electric Controller Series D8
4 pages 0.23 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Watlow Electric SERIES146, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Watlow Electric SERIES146 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Watlow Electric SERIES146. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Watlow Electric SERIES146 should contain:
- informations concerning technical data of Watlow Electric SERIES146
- name of the manufacturer and a year of construction of the Watlow Electric SERIES146 item
- rules of operation, control and maintenance of the Watlow Electric SERIES146 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Watlow Electric SERIES146 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Watlow Electric SERIES146, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Watlow Electric service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Watlow Electric SERIES146.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Watlow Electric SERIES146 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 ■ Watlow Series 146 User’ s Manual Series 146 User’ s Manual T emperature Regulator 1241 Bundy Boulev ard, P .O . Box 5580, Winona, Minnesota USA 55987-5580 Phone: +1 (507) 454-5300, F ax: +1 (507) 452-4507, Internet: http://www .watlow .com Registered Company Winona, Minnesota USA TO T AL 3 Y ear W arranty CUST OM ER SA TISF A CTION $5.00 [...]
-
Page 2
Figure 2a — Series 146 dimensions. Sub-Panel Mounting the Series 146 NOTE: FM approval requires limit switches to be suitably enclosed to minimize casual readjustment of set temperature. 1. Using the controller as a location template, mark both mounting holes. 2. Drill two 5 mm (0.19 in.) diameter holes in the desired panel location. See Figure 2[...]
-
Page 3
120V Å 146_ - 1 _ _ _ - 0000 230 to 240 V Å 146_ - 2 _ _ _ - 0000 24V Å 146_ - 3 _ _ _ - 0000 NOTE: The line voltage is specified by your model number . ç WARNING: T o avoid potential electric shock, use National Electrical Code safety practices when wiring and connecting this unit to a power source and to electrical sensors or peripheral devic[...]
-
Page 4
4 ■ Watlow Series 146 User’ s Manual Figure 4 — System wiring examples. 1 2 3 4 8 9 10 11 12 5 6 7 13 Series 102 Temperature Controller 102C-16XX-1000 4 (+) 5 (-) 120V Å L1 L2 1 3 6 7 89 1 CR-1 1 1 11 14 (+) 10 15 (-) 11 13 12 14 13 17 1 2 2 2 SSR-240-10A-DC1 Solid-State Relay 10 (+) (-) Heater 48 to 260 V Å out 3 to 32 V Î (dc) in. Series[...]
-
Page 5
Declaration of Conformity Series 146 W A TLOW WINONA 1241 Bundy Boulevard Winona, Minnesota 55987 USA Français Declara que el producto siguiente: Español Designación: Serie 146 Números de modelo: 146E - (1, 2 ó 3) (100-999) - (1, 2, 3 ó 4) (Cualquier combinación de tres números y letras) Clasificación: Control de temperatura, Categoría de[...]
-
Page 6
(2012) 146 _ - _ _ _ _ - _ _00 Output T ype E = Electromechanical rela y , 8A, Form C Line V oltage 1 = 120V Å 2 = 230V Å to 240V Å 3 = 24V Å Input and Range T ype E 619 = 0 to 799 ° C (32 to 1470 ° F) Ty p e J 601 = 0 to 315 ° C (32 to 600 ° F) 602 = 0 to 750 ° C (32 to 1382 ° F) 615 = Fixed at 315 ° C (600 ° F) 618 = -17 to 93 ° C (0[...]