A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Wayne ESP45, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Wayne ESP45 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Wayne ESP45. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Wayne ESP45 should contain:
- informations concerning technical data of Wayne ESP45
- name of the manufacturer and a year of construction of the Wayne ESP45 item
- rules of operation, control and maintenance of the Wayne ESP45 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Wayne ESP45 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Wayne ESP45, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Wayne service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Wayne ESP45.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Wayne ESP45 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    © 2010 WA YNE Pumps 353502-001 3/10 24-V olt Backup Sump Pump OPERA TING INSTRUCTIONS AND P AR TS MANUAL PLEASE READ AND SA VE THESE INSTRUCTIONS. READ CAREFULL Y BEFORE A TTEMPTING TO ASSEMBLE, INST ALL, OPERA TE OR MAINT AIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMA TION. F AILURE TO COMPL Y WITH INSTRUCT[...]

  • Page 2

    2 Operating Instructions and Parts Manual www .waynepumps.com A ground fault cir cuit interrupter is required. This pump must only be used to pump clear water . This pump is not designed to handle effl uent, salt water , brine, laundry discharge or any other application which may contain caustic chemicals and/or foreign materials. Pump damage may [...]

  • Page 3

    3 Model ESP45 www .waynepumps.com PUMP INST ALLA TION Installation of this unit may take several hours. Before disabling your main pump, have ready an appr opriate means of evacuating the sump. 1. T urn power to main pump off. 2. Pump must be installed using 11/4” or 11/2” rigid PVC piping. PUMP INST ALLA TION The ESP45 can be installed as a ba[...]

  • Page 4

    4 Operating Instructions and Parts Manual www .waynepumps.com W ear safety goggles when connecting batteries. Battery connections should be made in a well-ventilated area. 1. Place battery box within six feet of the sump and a 115 V AC separately fused outlet. The outlet must be protected by a ground fault circuit interrupter (GFCI). The area must [...]

  • Page 5

    5 Model ESP45 OPERA TION Always disconnect the power source befor e attempting to install, service, relocate or maintain the pump. Never touch sump pump, pump motor , water or discharge piping when pump is connected to electrical power . Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water . Fatal ele[...]

  • Page 6

    6 Operating Instructions and Parts Manual TROUBLESHOOTING CHART Symptom Possible Cause(s) Corrective Action Pump won't run 1. Connections not secure 2. Low or defective battery 3. Float switch stuck 4. Defective or blown fuse 1. Check all connections 2. Check battery and replace if low or defective 3. Make sure nothing is interfering with oper[...]

  • Page 7

    7 Model ESP45 www .waynepumps.com FOR REPLACEMENT P ARTS OR TECHNICAL ASSIST ANCE, CALL 1-800-237-0987 Please provide following information: - Model number - Serial number (if any) - Part description and number as shown in parts list Address parts correspondence to: WA YNE Water Systems 101 Production Drive Harrison, OH 45030 U.S.A. REP AIR P ARTS [...]

  • Page 8

    8 Operating Instructions and Parts Manual www .waynepumps.com LIMITED WARRANTY For one year from the date of purchase, WA YNE Pumps ("WA YNE") will repair or re place, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by W A YNE to be defective in materials [...]

  • Page 9

    9 Fr © 2010 WA YNE Pumps 353602-001 3/10 MÉMENTO : Gardez votre pr euve datée d‘achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. Pompe de vidange de secours 24 volts INSTRUCTIONS D'UTILISA TION ET MANUAL DE PIÉCES PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULL Y BEFORE A[...]

  • Page 10

    Instructions d‘Utilisation et Manual de Pièces 10 Fr Un interrup-teur pour protéger contr e un défaut de mise à la terre (DDFT) est exigé. Cette pompe est conçue pour le pompage de l’eau claire seulement. Cette pompe n’est pas conçue pour les substances qui contiennent les produits chimiques caustiques et/ou les matières étrangèr es[...]

  • Page 11

    Modèle ESP45 11 Fr • Le CB/AC est conçu seulement pour la pompe de WA YNE Water Systems, il NE doit P AS être utilisé à toutes autres fins. LE SYSTÈME P ASSERA À L'ALARME SI: • On entend un bip d'alarme si le moteur de la pompe fonctionne. • On entend une alarme continue si le fusible de la pompe du panneau avant grille. • [...]

  • Page 12

    Instructions d‘Utilisation et Manual de Pièces 12 Fr minimum car cela réduit l’écoulement de sortie de la pompe. Le tuyau qui sort de la structure de l’édifi ce devrait être en pente vers le bas pour que l’eau ne gèle pas dans le tuyau. En installant le tuyau de décharge distinct, percer dans le mur extérieur avec l’équipement d[...]

  • Page 13

    Modèle ESP45 13 Fr T oujours débrancher le c.a. et retir er le fusible de la pompe avant de brancher ou débrancher la batterie. 1. Choisir un emplacement convenable sur le plancher près du puisard, pour placer le boîtier de batterie. S'assurer que le cordon du CB/AC atteigne le courant c.a. et que le cordon de la pompe de puisard atteigne[...]

  • Page 14

    Instructions d‘Utilisation et Manual de Pièces 14 Fr GUIDE DE DÉP ANNAGE Symptôme Cause(s) Possible(s) Mesures Corr ectives Pompe ne fonctionne pas 1. Raccords ne sont pas sûrs 2. Batterie faible ou défectueuse 3. Interrupteur à fl otteur coincé 4. Fusible défectueux ou sauté 1. Vérifi er tous les raccords 2. Vérifi er la batterie e[...]

  • Page 15

    Modèle ESP45 15 Fr POUR DES PIÈCES DE RECHANGE, COMPOSER 1-800-237-0987 S’il vous plaìt fournir l’information suivante : - Numéro de modèle - Numéro de série (si applicable) - Description et numéro de pièce d’après la liste de pièces Correspondance : WA YNE Pumps 101 Production Drive Harrison, OH 45030 U.S.A. No. de Réf. Descripti[...]

  • Page 16

    Instructions d‘Utilisation et Manual de Pièces 16 Fr GARANTIE LIMITÉE For one year from the date of purchase, WA YNE Pumps ("WA YNE") will repair or re place, at its option, for the original purchase Pour un an à compter de la date d’achat, WA YNE Water Systems (“W A YNE”) vas réparer ou remplacer , à son option, pour l’ach[...]

  • Page 17

    17 Sp © 2010 WA YNE Pumps 353602-001 3/10 MÉMENTO : Gardez votre pr euve datée d‘achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. Bomba de r espaldo para sumider os MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PIEZAS POR F A VOR LEA Y GUARDE EST AS INSTRUCCIONES. LÉALAS CUIDADOSAMENTE ANT[...]

  • Page 18

    Manual de Instrucciones de Operación y Piezas 18 Sp Esta bomba sólo debe usarse para bombear aguas limpias. Esta bomba no está diseñada para bombear efl uentes, agua salada, salmuera,agua con detergentes o en ningún otro líquido que contenga químicos causticos y/o residuos y partículas. Ésto le ocasionaría daños a la bomba y cancelaría[...]

  • Page 19

    Modelo ESP45 19 Sp BOMBA: • La bomba se encenderá cuando el interruptor de flotador se eleve. El motor de la bomba continuará funcionando durante 15 segundos después de que baje el flotador . INST ALACIÓN DE BOMBA La instala-ción de esta bomba podría tomarle varias horas. Antes de desconectar temporalmente la bomba principal, cerciór ese d[...]

  • Page 20

    Manual de Instrucciones de Operación y Piezas 20 Sp MÉTODO 2 Si no es posible lograr una descarga separada y dedicada como en el Método 1, la bomba ESP45 puede conectarse a la tubería de descarga de la bomba que funciona con CA, instalando un conector "Y". Se requerirán dos válvulas de retención. 1. Coloque la ESP45 sobre una super[...]

  • Page 21

    Modelo ESP45 21 Sp ¡Riesgo de choque eléctrico! Use un interruptor de circuito de descarga a tierra (GFCI) para reducir el riesgo de choque eléctrico mortal. Asegúrese de que la conexión a tierra del receptáculo esté graduada para 5 amp. por lo menos. Siempre desconecte la corriente CA y retir e el fusible de la bomba antes de conectar o des[...]

  • Page 22

    22 Sp GUÍA DE DIAGNÓSTICO DE A VERÍAS Problema Posible(s) Causa(s) Acción Correctiva La bomba no funciona 1. Conexiones fl ojas 2. Batería baja o defectuosa 3. Interruptor de fl otador atascado 4. Fusible defectuoso o quemado 1. Revise todas las conexiones 2. Revise la batería y reemplácela si está baja o defectuosa 3. Asegúrese de que n[...]

  • Page 23

    Modelo ESP45 23 Sp N°. de Ref. Descripción Númer o de pieza Ctd. 1 Bomba 06710 1 2 PS/BC (suministro de energía/carga- dor de batería) 30260-002 1 3 Impulsor 29884-001 1 4 Anillo de desgaste 28183-001 1 5 Placa del impulsor 15958 1 6 Sello 21203-001 1 7 Juego de fl otador 60120-001 1 * Únicamente piezas de repuesto 1 2 3 4 5 6 7 P ARA ORDENA[...]

  • Page 24

    Manual de Instrucciones de Operación y Piezas GARANTÍA LIMIT ADA Durante un año a partir de la fecha de compra del comprador original, la compañía WA YNE Pumps ("WA YNE") reparará o re emplazará, según lo decida, cualquier pieza de esta bomba de desagüe o bomba de agua que se encuentre defectuosa debido a materiales usados o proc[...]