Wayne GPH400 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Wayne GPH400, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Wayne GPH400 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Wayne GPH400. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Wayne GPH400 should contain:
- informations concerning technical data of Wayne GPH400
- name of the manufacturer and a year of construction of the Wayne GPH400 item
- rules of operation, control and maintenance of the Wayne GPH400 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Wayne GPH400 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Wayne GPH400, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Wayne service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Wayne GPH400.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Wayne GPH400 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Engine Driven Semi-T rash Pump Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for[...]

  • Page 2

    Operating Instructions and Replacement Parts List 2 An air leak in the suction line may prevent priming of the pump. Use of thread sealant is recommended. Suction lines must be reinforced hose or rigid pipe. Non-reinforced hose will collapse due to the suction created by the pump and prevent pump from operating. 3. A check valve must be used in the[...]

  • Page 3

    3 Operating Instructions and Replacement Parts List FEET FRICTION LOSS IN 100 FEET OF PLASTIC PIPE Gallons Per Minute Pipe Size 20 25 30 40 50 60 80 100 120 1 1 / 4 5.6 8.5 11.9 20.2 30.5 1 1 / 2 2.6 4.0 5.5 9.4 14.3 19.9 34.2 2 1.2 1.6 2.8 4.2 5.8 9.9 15.0 21.2 2 1 / 2 1.2 1.8 2.5 4.2 6.3 8.8 Performance Information Semi- T rash Pump Perfo rmanc e[...]

  • Page 4

    4 ® LAY FLAT DISCHARGE HOSE PART #16511 • Economical • Lightweight • Resistant to oils, light chemicals, abrasion and sunlight • Will not rot, mildew or absorb water Hose couples one end with 2” hose thread. One 25 ft. hose per carton SUCTION HOSE PART #16510-002 • Reinforced to prevent collapse under suction Hose coupled both ends wit[...]

  • Page 5

    F o r R e p l ac em e nt P a rt s, ca ll 1- 80 0 -2 3 7 -0 98 7 5 Operating Instructions and Replacement Parts Manual Item Part No. Description GPH400 GPH550 Qty 1 Honda Engine 57813-001 57812-001 1 2 Shaft Seal Kit 66048-WYN1 66047-WYN1 1 3 Suction Flange 42008-001 42007-001 1 4 Flapper Check Valve 37307-001 37306-001 1 5 Discharge Flange Kit 6605[...]

  • Page 6

    6 Operating Instructions and Replacement Parts List Limit ed W arranty For three years from date of purchase, Wayne Water Systems (”Wayne Water Systems“) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (”Product“) found upon examination by Wayne Water Systems to be defecti[...]

  • Page 7

    7 Les pompes Wayne sont des pompes à l’eau centrifuges d’utilisation générale. Ce manuel contient de l’information très importante qui est fournie pour la SÉCURITÉ et pour ÉVITER LES PROBLÈMES D’ÉQUIPEMENT. Rechercher les symboles suivants pour cette information. Danger indique une situation hasardeuse imminente qui RÉSULTERA en p[...]

  • Page 8

    Operating Instructions and Replacement Parts List 8 La conduite de succion ou le tuyau rigide doit être renforcé pour éviter qu’il ne s’affaisse à cause de la succion créée par la pompe. 3. Il faut utiliser une soupape anti- retour dans la conduite d’aspiration pour maintenir la capacité d’auto- amorçage. S’il n’y en a pas, il f[...]

  • Page 9

    3 FR PERTE DE POMPE A CAUSE DE 100 PIEDS DU TUYAU DE PLASTIQUE Diamètre Gal/minute du Tuyau 20 25 30 40 50 60 80 100 120 1 1 / 4 5.6 8.5 11.9 20.2 30.5 1 1 / 2 2.6 4.0 5.5 9.4 14.3 19.9 34.2 2 1.2 1.6 2.8 4.2 5.8 9.9 15.0 21.2 2 1 / 2 1.2 1.8 2.5 4.2 6.3 8.8 Information sur la performance Performance de la pompe à résidus Tête de décharge Gall[...]

  • Page 10

    10 TUYAU DE DÉCHARGE À DÉPOSER À PLAT PIÈCE NO 16511 • Économique • Léger • Résistant aux huiles, produits chimiques légers, abrasion et rayons du soleil • Ne pourrit pas, ne moisit pas et n’absorbe pas l’eau Tuyau couplé à une extrémité avec un filet de tuyau de 2 po. Un tuyau de 25 pieds par carton TUYAU D’ASPIRATION PI[...]

  • Page 11

    Pou r p ièc es de r echang e, co mpo ser 1-800 -23 7-09 87 11 Instructions d’Utilisation et Manuel de Pièces de Rechange No. de Réf Description GPH400 GPH550 Qty 1 Moteur Honda 57813-001 57812-001 1 2 Trousse de joint d’étancheité 66048-WYN1 66047-WYN1 1 3 Bride à succion 42008-001 42007-001 1 4 Clapet anti-retour à battant 37307-001 373[...]

  • Page 12

    Garantie Limitée Pendant un an à compter de la date d’achat, Wayne Water Systems ("Wayne") va réparer ou remplacer, à sa discrétion, pour l’acheteur original toute pièce ou pièces du Kit D’Étang, de ces Pompes De Puisard ou Pompes À Eau ("Produit") déterminées défectueuses, par Wayne, soit pour les matériaux o[...]