Go to page of
Similar user manuals
-
Septic System
Wayne DSP75
12 pages 0.31 mb -
Septic System
Wayne 331301-001
20 pages 5.56 mb -
Septic System
Wayne 330502-001
24 pages 2.26 mb -
Septic System
Wayne EFL30
12 pages 0.28 mb -
Septic System
Wayne 330102-001
20 pages 1.39 mb -
Septic System
Wayne SEP8
8 pages 0.88 mb -
Septic System
Wayne RPPCAP50
20 pages 5.56 mb -
Septic System
Wayne SEL40
20 pages 0.82 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Wayne SEL50, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Wayne SEL50 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Wayne SEL50. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Wayne SEL50 should contain:
- informations concerning technical data of Wayne SEL50
- name of the manufacturer and a year of construction of the Wayne SEL50 item
- rules of operation, control and maintenance of the Wayne SEL50 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Wayne SEL50 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Wayne SEL50, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Wayne service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Wayne SEL50.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Wayne SEL50 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
© 2009 Wayne W ater Systems 330002-001 3/09 Sewage Pump Operating Instructions and Parts Manual Models SEL40 and SEL50 Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failur e to comply with i[...]
-
Page 2
2 Operating Instructions and Parts Manual Gener al Saf ety In format ion (Continued) GENERAL SAFETY 1. Know t he pump applic ation, limitations, and po ten tial hazards. Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Personal injury and/or propert[...]
-
Page 3
3 Models SEL40 and SEL50 www .waynepumps.com Gener al Saf ety In format ion (Continued) The pump motor is equipped with automatic resetting thermal pr otector and may restart unexpectedly . Protector tripping is an indication of motor overloading as a result of operating the pump at low heads (low discharge restriction), excessively high or low vol[...]
-
Page 4
4 Operating Instructions and Parts Manual www .waynepumps.com Maintenance (Continued) 5. Submer ge the complet e pump i n a disinf ectant so lu tion (1 0% chlo rine bleach solution) for at least one hour before handling the pump. 6. Clean all dir t and d eposits from th e pump f loat. M ake sur e float moves freely after cleaning. 7. Clean all dir [...]
-
Page 5
5 Models SEL40 and SEL50 www .waynepumps.com 1 Motor housing 28088-001 1 2 Power cord 31026-001 1 3 #8 - 16 x 1 inch screw 67112-001 6 4 Motor housing gasket 17456-002 1 5 Impeller 17317-001 1 6 V olute (includes 6 screws) 23272-001 1 7 Dielectric oil 55932 2.2 pints 8 Mechanical switch kit 60022-001 1 9 Oil plug 37303-001 1 Reference Number Descri[...]
-
Page 6
6 Operating Instructions and Parts Manual www .waynepumps.com Limited W arranty For one year from the date of pur chase, W ayne W ater System s ("Way ne") will rep air or re place, at its optio n, for the origi nal purcha ser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon exami nation by Wayne to be defectiv[...]
-
Page 7
Instructions d‘Utilisation et Manual de Pièces Mod è les SEL40 et SEL50 V euillez lire et conserver ces instructions. Lire attentivement avant de commencer à assembler , installer , faire fonctionner ou entr etenir l‘appareil décrit. Pr otégez-vous et les autres en observant toutes les informations sur la sécurité. Négliger d‘applique[...]
-
Page 8
Instructions d‘Utilisation et Manual de Pièces 8 Fr Généralités Sur La Sécurité (Suite) 1. Se f ami li ar is er av ec l ’a pp lic at io n, le s limites et les hasards potentiels de la pompe. Ne p as uti lis er pou r le pom pa ge des l iqu ide s inf la mma ble s ou exp lo sif s tels que l’essence, l’huile à c ha uf fa ge, le ké r os?[...]
-
Page 9
Mod è les SEL40 et SEL50 9 Fr Généralités Sur La Sécurité (Suite) Le moteur de la pompe est équipé d’un protecteur thermique à réenclenchement automatique et peut se mettre en mar che subitement. Le déclenchement du protecteur est une indication de surcharge du moteur résultant du fonctionnement de la pompe à basse pression (r estric[...]
-
Page 10
Instructions d‘Utilisation et Manual de Pièces 10 Fr Entretien (Suite) 2. Enleve r le co uvercle du bass in et déb rancher la tuy auterie de déchar ge avan t de so ulever l a pompe du bassin. 3. Inspec ter la pompe p ar inter valles réguli ers pou r le fo nctionne ment correc t. S’il y a eu des cha ngement s depuis l’acha t du mo dèle, l[...]
-
Page 11
Mod è les SEL40 et SEL50 11 Fr Guide de Dépannage (Suite) Symptôme Cause(s) Possible(s) Mesure Corr ective La pompe fonctionne mais délivre peu ou pas d’eau (Suite) 4. Pompe fonctionne à l’envers 5. Po mpe d e m au va is e ta i ll e po ur l’application 6. Clapet pris dans la position fermée ou installée à l’envers 7. Soupape d’arr[...]
-
Page 12
Instructions d‘Utilisation et Manual de Pièces 12 Fr Garantie Limitée For one year from the date of purchase, Wayne W ater Systems ("Wayne") will repair or re place, at its option, for the original purchase Pour un an à compter de la date d’achat, W ayne Water Systems (“Wayne ”) vas répar er ou rempla cer , à son option, pour[...]
-
Page 13
Manual de Instrucciones de Operación y Piezas Modelos SEL40 y SEL50 Por favor lea y guarde estas instrucciones. Léalas cuidadosamente antes de tratar de montar , instalar , operar o dar mantenimiento al producto aquí descrito. Protéjase usted mismo y a los demás observando toda la información de seguridad. ¡ El no cumplir con las instruccion[...]
-
Page 14
Manual de Instrucciones de Operación y Piezas 14 Sp Infor macion es Gen erales de Seguridad (Continuación) GENERALES DE SEGURIDAD 1. Famili arícese con la s aplica ciones adecua das par a el eq uipo, su s limitaciones y los peligros al usarlo. No use esta bomba para bombear fluídos inflamables o explosivos tales como gasolina, combustibles, ker[...]
-
Page 15
Modelos SEL40 y SEL50 15 Sp Infor macion es Gen erales de Seguridad (Continuación) 13. Es altamente recomendable que utilic e un to macorri entes qu e tenga un sist ema de cortacir cuito incorporado. Con súltele a un electr icista local p ara ver si ésto s están disponibles en su área. E l motor de la bomba tiene un sistema de protección tér[...]
-
Page 16
Manual de Instrucciones de Operación y Piezas 16 Sp Mantenimiento (Continuación) 3. Chequé e la bo mba per iódicame nte para v er si e stá en buen est ado. Si el sis tema ha cambia do despu és de instal ar la u nidad, debe des conecta r y reem plazar la bomb a. Sólo electr icistas califi cados de ben tratar de rep arar es ta unida d. Reparac[...]
-
Page 17
Modelos SEL40 y SEL50 17 Sp Guía de diagnóstico de averías (Continuación) Symptôme Cause(s) Possible(s) Mesure Corr ective La bomba funciona pero bombea muy poca agua o no bombea agua (Continuación) 4. La bomba está rotando en sentido contrario 5. La bo mb a n o es l a ad e cu ad a pa ra l a aplicación en que se está usando 6. La válvula [...]
-
Page 18
Manual de Instrucciones de Operación y Piezas 18 Sp Garantía Limitada Durante un año a partir de la fecha de compra del comprador original, la compañía Wayne Water Systems ("Wayne") reparará o re emplazará, según lo decida, cualquier pieza de esta bomba de desagüe o bomba de agua que se encuentre defectuosa debido a materiales us[...]
-
Page 19
Notes / Notas / Notes 19 SEL40, SEL50[...]
-
Page 20
Notes / Notas / Notes SEL40, SEL50 Operating Instructions and Parts Manual • Instructions d‘Utilisation et Manual de Pièces • Manual de Instrucciones de Operación y Piezas 20[...]