Go to page of
Similar user manuals
-
Boiler
Weil-McLain GV90+
16 pages 1.33 mb -
Boiler
Weil-McLain WMBC-1A
11 pages 2.79 mb -
Boiler
Weil-McLain 550-141-850/0599
96 pages 3.79 mb -
Boiler
Weil-McLain LGB-6
11 pages 0.99 mb -
Boiler
Weil-McLain EGH-125
36 pages 0.88 mb -
Boiler
Weil-McLain Gas-Fired Boiler
2 pages 0.74 mb -
Boiler
Weil-McLain CG Series 11
23 pages 1.21 mb -
Boiler
Weil-McLain LGB-23
12 pages 1.28 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Weil-McLain FLAME GUARDIAN WC-1A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Weil-McLain FLAME GUARDIAN WC-1A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Weil-McLain FLAME GUARDIAN WC-1A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Weil-McLain FLAME GUARDIAN WC-1A should contain:
- informations concerning technical data of Weil-McLain FLAME GUARDIAN WC-1A
- name of the manufacturer and a year of construction of the Weil-McLain FLAME GUARDIAN WC-1A item
- rules of operation, control and maintenance of the Weil-McLain FLAME GUARDIAN WC-1A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Weil-McLain FLAME GUARDIAN WC-1A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Weil-McLain FLAME GUARDIAN WC-1A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Weil-McLain service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Weil-McLain FLAME GUARDIAN WC-1A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Weil-McLain FLAME GUARDIAN WC-1A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
P art Number 550-141-807/0298 LGB Gas–fir ed boiler Contents Flame Guardian WMBC -1A RM7895C Controller Electronic Pilot System IRI Control Supplement I . Installation ..................... 2 II . Gas piping ...................... 5 III. Wiring ............................. 5 IV. Startup ......................... 1 0 V. Sequence of operation 1 1 [...]
-
Page 2
P art Number 550-141-807/0298 2 LGB (Series 2) — Control Supplement I Installation 1 . For use with LGB-6 through 12 boilers. 2 . L O CAL INSPECT OR MUST CER TIFY B OILER FOR IRI COMPLIANCE. 3 . Assemble pilot burner and flame sensor to main burners with pilot brackets. See Figures 2 and 3. Install ground wiring as shown in Figures 2 and 3. 4 . R[...]
-
Page 3
P art Number 550-141-807/0298 3 Flame Guardian WMBC-1A Electronic Pilot System – IRI Figure 2 Q179 pilot burner assembly Figure 3 Main flame sensor assembly I Installation – continued LGB-A56 Locating Slot Igniter Sensor Q179 Pilot Burner 10-32 x 5/16“ Machine Screws(2) Ground Leadwire: Connect to WMBC P anel T erminal G2 (Ground T erminal) P[...]
-
Page 4
P art Number 550-141-807/0298 4 LGB (Series 2) — Control Supplement 16 13 15 17 18 18 14 12 11 10 9 7 6 5 4 3 2 1 Boiler Jacket V ent to Outside Atmosphere Drip Leg Service V alve 9 Second motorized gas valve w/ on/off actuator 1 Manual main shut-off gas valve 2 Low gas pressure switch 3 Pilot manual shut-off valve 4 Motorized gas valve w/ on/off[...]
-
Page 5
P art Number 550-141-807/0298 5 Flame Guardian WMBC-1A Electronic Pilot System – IRI 1 . Size gas piping considering: a. Diameter and length of gas supply piping. b. Number of fittings. c . Maximum gas consumption (including any possible future expansion). d. Allo wable pressure dr op from gas meter ou tle t to boiler . For pr essure dro ps, see [...]
-
Page 6
Part Number 550-141-807/0298 6 LGB (Series 2) — Control Supplement P art Number 550-141-807/0298 7 Flame Guardian WMBC-1A Electronic Pilot System – IRI Figure 5 — WMBC-1A panel wiring schematic[...]
-
Page 7
P art Number 550-141-807/0298 8 LGB (Series 2) — Control Supplement Figure 6 — WMBC-1A panel wiring diagram – factory wiring[...]
-
Page 8
P art Number 550-141-807/0298 9 Flame Guardian WMBC-1A Electronic Pilot System – IRI Figure 7 — WMBC-1A field wiring diagram[...]
-
Page 9
P art Number 550-141-807/0298 10 LGB (Series 2) — Control Supplement IV Start -up Low Fire Adjustment 1 . Disable high fire by disconnecting the blue wire in the two-stage gas valve. 2 . Connect manometer to gas manifold (manometer must be capable of measuring 0” to 14” W .C.). 3 . T urn on electrical power sup ply and g as supply t o boiler [...]
-
Page 10
P art Number 550-141-807/0298 11 Flame Guardian WMBC-1A Electronic Pilot System – IRI V Sequence of operation 1 . Operating control begins startup sequence: a. Limit control contacts are closed. b. Purge timer is energized. 2 . Flame safeguard control pilot circuit energizes after 2.0 seconds. a. Pilot gas valve opens. b. Ignition transformer ene[...]
-
Page 11
P art Number 550-141-807/0298 12 LGB (Series 2) — Control Supplement W eil-McLain 500 Blaine Street Michigan City , IN 46360-2388 http://www .weil-mclain.com VI P arts list – T able 3 Description Size Vendor/Part Number Weil-McLain Part Number Primary Control Honey well RM789 5C1012 510-35 0-431 Prepurg e Timing Card 2 .0 Seco nds Honey well ST[...]