Go to page of
Similar user manuals
-
Boiler
Weil-McLain GOLD CGt SERIES
3 pages 0.04 mb -
Boiler
Weil-McLain LGB-4
8 pages 0.66 mb -
Boiler
Weil-McLain HE (Series 3)
23 pages 2.04 mb -
Boiler
Weil-McLain AFG
12 pages 1.48 mb -
Boiler
Weil-McLain LGB-10
11 pages 0.99 mb -
Boiler
Weil-McLain WJB1
4 pages 1.1 mb -
Boiler
Weil-McLain CGt SERIES
3 pages 0.04 mb -
Boiler
Weil-McLain D Gas Series 2
12 pages 1.18 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Weil-McLain STAR-34, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Weil-McLain STAR-34 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Weil-McLain STAR-34. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Weil-McLain STAR-34 should contain:
- informations concerning technical data of Weil-McLain STAR-34
- name of the manufacturer and a year of construction of the Weil-McLain STAR-34 item
- rules of operation, control and maintenance of the Weil-McLain STAR-34 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Weil-McLain STAR-34 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Weil-McLain STAR-34, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Weil-McLain service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Weil-McLain STAR-34.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Weil-McLain STAR-34 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
P art Number 550-110-268/0699 Special gas vent system vent and combustion Special gas vent system vent and combustion Special gas vent system vent and combustion Special gas vent system vent and combustion Special gas vent system vent and combustion air supplement air supplement air supplement air supplement air supplement V enting Supplement StaR [...]
-
Page 2
P art Number 550-110-268/0699 2 GOLD GV W ater boiler — Series 3 Combustion air supply Ref e r t o GV Series 3 Boiler Manual for sizing free area of combu stion/ven t ilation air opening s. All boilers experience some c ondensation in section assembly during start-up. U nlik e most con ventional boilers, condensation is minimized in the GV Series[...]
-
Page 3
P art Number 550-110-268/0699 3 StaR -34 V enting Supplement V ent termination V enting method definitions Direct vent — U ses outside c ombustion air w ith comb ust ion air connector piping seale d at al l joints and seams. Also known as “sealed c ombustion ” . Non-Direct vent — U ses inside comb ust ion air with no comb ustion air connect[...]
-
Page 4
P art Number 550-110-268/0699 4 GOLD GV W ater boiler — Series 3 Installation P re -installation planning 1. Follo w national, state, local or provincial c o des or regulations when venting GV boiler . 2. Choose vent method fro m those shown on page 5. 3. Select ve nt run compo nents fr om T able 2 . T able 3 states maximum ve nt run lengths and [...]
-
Page 5
P art Number 550-110-268/0699 5 StaR -34 V enting Supplement 26801 Air pipe V ent pipe StaR-34 vent starter tee Slope Slope vent pipe downward, t oward boiler , minimum ¼” per foot. Figure 3 GV direct vent through sidewall (using Weil-McLain V ent/Air Intake T ermination Kit) Figure 5 GV direct vent (using W eil-McLain Through-Roof or Through-Un[...]
-
Page 6
P art Number 550-110-268/0699 6 GOLD GV W ater boiler — Series 3 Installation — assembly Connect vent starter tee to boiler Follo w the inst ructions in the GV Series 3 Boiler Manual section II II II II II b b b b b to c onnect the vent starter tee to the boiler . Construct vent and optional combustion air run Follo w vent pipe manufacturer&apo[...]
-
Page 7
P art Number 550-110-268/0699 7 StaR -34 V enting Supplement Figure 8 Sidewall termination installation (non-direct venting) 26809 ¼" to ¾" between stop on ter mination and metal plate 4" galvanized slee v e (through 4 " hole for wa ll) ¹⁄₈ combustible Pipe sect ion Meta l pl at e Spacers (2) (to support and center vent i[...]
-
Page 8
P art Number 550-110-268/0699 8 GOLD GV W ater boiler — Series 3 W eil-McLain 500 Blaine Street Michigan City , IN 46360-2388 http://www .weil-mclain.com Installation — assembly continued Finish the vent installation Figure 11 Installation of condensate tubing Sealant recommended by vent pipe manufacturer must be used as indicated in their inst[...]