Westinghouse UL-ES-Parkway-WH10 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Westinghouse UL-ES-Parkway-WH10, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Westinghouse UL-ES-Parkway-WH10 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Westinghouse UL-ES-Parkway-WH10. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Westinghouse UL-ES-Parkway-WH10 should contain:
- informations concerning technical data of Westinghouse UL-ES-Parkway-WH10
- name of the manufacturer and a year of construction of the Westinghouse UL-ES-Parkway-WH10 item
- rules of operation, control and maintenance of the Westinghouse UL-ES-Parkway-WH10 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Westinghouse UL-ES-Parkway-WH10 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Westinghouse UL-ES-Parkway-WH10, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Westinghouse service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Westinghouse UL-ES-Parkway-WH10.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Westinghouse UL-ES-Parkway-WH10 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    UL -ES-Parkwa y-WH10 OWNER' S MANUAL MANUAL DEL USUARIO Please write model number here for future reference: / Por fav or , incluya el número del modelo aquí para futura referencia: Net Weight: 14.08 LBS P es o N et o : 6. 39 K GS P arkw a y[...]

  • Page 2

    2 UL -ES-Parkwa y-WH10 1. Installation work and elec trical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFP A 70-1999), including fire-rated construction. 2. Use this unit only in the manner intended by the manufacturer . If you have any questions contact the manufacturer . 3. After making [...]

  • Page 3

    3 UL -ES-Parkwa y-WH10 1. El trabajo de instalación y el cableado eléctrico los deben efec tuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFP A 70-1999), incluyendo las de incendio. 2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante. 3. Desp[...]

  • Page 4

    4 UL -ES-Parkwa y-WH10 FEA TURES C ARA C TERÍSTICAS DOWNROD INST ALLA TION INST ALACIÓN CON V ARILLA VERTICAL For normal ceilings Para cielorrasos normales V AUL TED CEILING INST ALLA TION INST ALACIÓN P ARA CIEL ORRASOS ABOVEDADOS May require a longer downrod (sold separately) Podría requerir una varilla vertical más larga (se vende por separ[...]

  • Page 5

    5 UL -ES-Parkwa y-WH10 COMBO-BLADE Combo-Blades feature two high quality finishes on one blade. Select the one that best complements your decor , or change the style with just a flip of the blade. NOTE: Combo-Blade finishes var y , depending upon model. ASP AS DE DOBLE CARA Las aspas del rotor de doble cara presentan dos super ficies con un acabado[...]

  • Page 6

    6 UL -ES-Parkwa y-WH10 6 Unpack and inspect fan carefully to be certain all conten ts are included. T urn off power at fuse box to avoid possible elec trical shock. 1 Use metal outlet box suitable for fan suppor t (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a struct[...]

  • Page 7

    7 UL -ES-Parkwa y-WH10 Remove the screws and star washers from the two mating holes (1) on the canopy . Loosen (do not remov e) the screws in the mating slots (2) on the canopy . Rotate the mounting bracket and remove from the canopy . Quite los tornillos y las dos arandelas en estrella de los dos orificios coinciden tes (1) del dosel. Afloje (no q[...]

  • Page 8

    8 UL -ES-Parkwa y-WH10 MOUNTING BRA CKET INST ALLA TION INST ALACIÓN CON SOPORTE DE MONT A JE Install mounting brack et to outlet box in ceiling using the screws and washers provided with the outlet box. Instale el soporte de montaje a la caja de embutir del cielorraso con la tornillería suministrada con la caja de embutir . 4 5 MOUNTING OPTIONS [...]

  • Page 9

    9 UL -ES-Parkwa y-WH10 FL USH MOUNT OPTION OPCIÓN DE INST AL A CIÓN AL RAS 6 G ui de m ot o r wi r es t h ro u gh t he b as e of t h e c a no p y a s sh o w n a n d a t ta c h ca no p y directly to top of motor housing with flush mount screws and lock washers provided . Tigh ten screws sec ur ely . De s li c e l o s c a bl es d e l m o to r a tr [...]

  • Page 10

    10 UL -ES-Parkwa y-WH10 9 Loosen downrod ball (1) fr om downr od (2) by removing set scr ew (3). Afloje la esfera de la varilla vertical (1) de la varilla vertical (2) quitando el tornillo (3). 2 3 1 EX TENDED DOWNROD OPTION OPCIÓN C ON VARILLA VERTIC AL MÁS L ARGA NORMAL DOWNROD OPTION OPCIÓN C ON VARILLA VERTIC AL P ARA CIEL ORRASO NORMAL 8 2 [...]

  • Page 11

    11 UL -ES-Parkwa y-WH10 EX TENDED DOWNROD OPTION OPCIÓN C ON VARILLA VERTIC AL MÁS LARGA 10 S li de d o wn r od b al l (1 ) o ff o f d o wn r o d a n d re m ov e p i n ( 2 ). De s li c e l a es f er a de l a v ar il l a v ert ic a l ( 1 ) h a st a se p ar a rl a de l a v ar i ll a v ert ic a l y q u it e el p as a do r (2 ) . 2 1 11 Re-install pi[...]

  • Page 12

    12 UL -ES-Parkwa y-WH10 Feed motor lead wires through downrod/canopy assembly and inser t downrod into downrod yok e. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yok e and downrod . Inser t clamp pin (2) into cross pin until it snaps into place. Tigh ten set screws (3) in yok e. P ase los hil[...]

  • Page 13

    13 UL -ES-Parkwa y-WH10 MOUNTING MONT A JE 14 W i th b r ac k et h ol d in g fa n as s em bl y , ma k e el ec tr i ca l co n ne ct io n s u s in g th e following step for wiring instruc tions . C o n l a pi e za d e mo n ta j e s u je ta n do e l co n ju n to d el v e n ti la d or , h ag a l as c on e xi on e s el éc tr ic a s de a cu er do a la s[...]

  • Page 14

    14 UL -ES-Parkwa y-WH10 WIRING OPTIONS OPCIÓN DE CABLEADO 16 Follo w diagram above to make wiring connec tions for wall contr ol operation. 15 Follo w diagram above to make wiring connec tions for fan pull chain contr ol. PULL CHAIN WIRING OPTION WALL CONTROL WIRING OPTION Sig a las i nstr ucci ones del di agra ma an ter ior pa ra ha cer las co ne[...]

  • Page 15

    15 UL -ES-Parkwa y-WH10 SECURE TO CEILING ASEGURE EL VENTILADOR AL CIEL ORRASO 17 1 3 2 The canopy has two mating slots (1) and t wo mating holes (2). P osition both slots on canopy directly under and in line with t wo screws in the mounting bracket (3). Lift the canopy , allowing the two screws and star wahers to slide into the mating slots. Rotat[...]

  • Page 16

    16 UL -ES-Parkwa y-WH10 Check the motor for plastic shipping stabilizer tabs (1), and remove them if they are present. Attach blade assembly to motor using the noise -dampening motor gaskets (2) and motor screws provided. Tighten screws securely . NOTE: Some models do not utilize motor gaskets , washers , or stabilizer tabs. V er if iq u e si h ay [...]

  • Page 17

    17 UL -ES-Parkwa y-WH10 Attach the switch housing cap using three small screws provided. Conecte la tapa del alojamiento del interrupt or con los tres tornillos pequeños incluidos. Connect the wire plugs from the motor (1) to the wire plugs from the light kit (2), white to white, and black to black. Attach light kit to the switch housing using thr[...]

  • Page 18

    18 UL -ES-Parkwa y-WH10 23 6 1 2 3 4 5 Install glass (1) onto light kit and tighten rubber/ metal washer (2) (rubber side facing the glass), and nut (3) onto bottom of glass. Make sure ceiling fan pull chain is threaded through the side hole in the bottom of the glass. Place decorative cap (4) ov er bottom of glass and secure by tightening decorati[...]

  • Page 19

    19 UL -ES-Parkwa y-WH10 24 Assemble decorative fob and extension chains from har dware bag to fan pull chains by inser ting end of chain into chain coupling. Confirm chains are held by lightly pulling both chains in coupling . Sujetar las cadenas largas de tiro con las piezas finales correspondien tes, a las cadenas del ventilador , introduciendo e[...]

  • Page 20

    20 UL -ES-Parkwa y-WH10 Operation T urn on the power and check operation of fan. T he pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool wea ther depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls directio[...]

  • Page 21

    21 UL -ES-Parkwa y-WH10 Operación Encienda el ventilador y verifique su funcionamiento . La cadenilla de tiro contr ola las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado . Las velocidades para clima cálido o frío dependen de fac tores como el tamaño de la hab[...]

  • Page 22

    22 UL -ES-Parkwa y-WH10 TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this T rouble Shooting Chart. If a problem cannot be remedied, plea[...]

  • Page 23

    23 UL -ES-Parkwa y-WH10 GUÍA P ARA SOLUCIONAR PROBLEMAS Si tiene dificultades para hacer funcionar su nuevo ventilador , podría ser a causa del armado , instalación o cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar proble[...]

  • Page 24

    UL -ES-Parkwa y-WH10 W estinghouse Lighting Corporation 12401 McNult y Road Philadelphia, P A 19154 U.S.A. W estinghouse Lighting Corporation, a W estinghouse Elec tric Corporation licensee is a register ed trademark of W estinghouse Electric Corporation Made in China © 2010 Westinghouse Lighting Corporation W estinghouse Lighting Corporation 1240[...]