White Rodgers 1F80-41 manual

1
2
3
4
5
6

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of White Rodgers 1F80-41, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of White Rodgers 1F80-41 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of White Rodgers 1F80-41. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of White Rodgers 1F80-41 should contain:
- informations concerning technical data of White Rodgers 1F80-41
- name of the manufacturer and a year of construction of the White Rodgers 1F80-41 item
- rules of operation, control and maintenance of the White Rodgers 1F80-41 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of White Rodgers 1F80-41 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of White Rodgers 1F80-41, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the White Rodgers service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of White Rodgers 1F80-41.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the White Rodgers 1F80-41 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    To prevent electrical shock and/or equipment dam- age, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. Do not short out terminals on gas valve or primary control to test[...]

  • Page 2

    2 INST ALLA TION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the [...]

  • Page 3

    3 RH Y 24 VAC 120 VAC Hot Neutral THERMOSTAT SYSTEM G W Figure 10. Typical wiring diagram for heat pump with heat active changeover relay TRANSFORMER Changeover Relay* RC O B JUMPER WIRE Compressor Contactor JUMPER WIRE * Changeover Relay is energized when the system switch is in the HEAT position Fan Relay RH Y 24 VAC 120 VAC Hot Neutral THERMOSTA[...]

  • Page 4

    4 CAUTION ! CHECK THERMOSTAT OPERATION If at any time during testing your system does not operate properly, contact a qualified serviceperson. Fan Operation If your system does not have a G terminal connection, skip to Heating System . 1. Turn on power to the system. 2. Move FAN switch to ON position. The blower should begin to operate. 3. Move FAN[...]

  • Page 5

    5 WEEKDAY (5 DAY) WEEKEND (2 DAY) Start Time* Temperature Start Time* Temperature 1ST HEAT 2ND HEAT 3RD HEAT 4TH HEAT 1ST COOL 2ND COOL 3RD COOL 4TH COOL SAMPLE Heating/Cooling Schedule Plan Period 5:30 AM 8:00 AM 5:00 PM 10:30 PM 6:30 AM 2:00 PM 5:00 PM 10:30 PM 7:00 AM 11:00 AM 6:00 PM 11:30 PM 7:00 AM 12:30 PM 6:00 PM 11:30 PM 68 ° F 70 ° F 70[...]

  • Page 6

    your program time periods, and the temperatures you want during each period. You may also want to look at the sample program table to get an idea of how the thermostat can be programmed. Entering Your Program Follow these steps to enter the heating and cooling programs you have selected. The thermostat should be programmed in the 12-hour format, th[...]