A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Wibur Curtis Company ALPHA 6X, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Wibur Curtis Company ALPHA 6X one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Wibur Curtis Company ALPHA 6X. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Wibur Curtis Company ALPHA 6X should contain:
- informations concerning technical data of Wibur Curtis Company ALPHA 6X
- name of the manufacturer and a year of construction of the Wibur Curtis Company ALPHA 6X item
- rules of operation, control and maintenance of the Wibur Curtis Company ALPHA 6X item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Wibur Curtis Company ALPHA 6X alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Wibur Curtis Company ALPHA 6X, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Wibur Curtis Company service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Wibur Curtis Company ALPHA 6X.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Wibur Curtis Company ALPHA 6X item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
ALPHA AUTOMATIC COFFEE BREWERS Wilbur Curtis Co., Inc. - S E R V I C E M A N U A L INCLUDES THE FOLLOWING UNITS: ALPHA 3X ALPHA 3XR ALPHA 3XL ALPHA 2X ALPHA 1X ALPHA 6X Carton Content s Automatic Coffee Brewer . . . . . . . . . . . Brewcone . . . . . . . . . . . . . . . . . . . . . . . . . Paper Filters . . . . . . . . . . .[...]
-
Page 2
ALPHA X The Alpha X series of automatic coffee brewers require installation to be in compliance with all local water and electrical power codes. The Alpha is designed to brew 12 cups at a time. The Alpha 3X, 3XL and 3XR have three warmer plates that allow up to three decanters to be kept at serving temperature. The hot water faucet lets you draw ho[...]
-
Page 3
[ 1 ] SET -UP INSTRUCTIONS 1. WATER CONNECTION: A 3/8" NPT x 1/4" flare elbow fitting is supplied with this brewer for the water line connection. Use 1/4" copper tubing and flare nut to hook up your water source behind the machine. It is important to use a good water filter in the system before water enters the Alpha brewer. CAUTION [...]
-
Page 4
[ 2 ] 1 . Place a paper filter into the brew cone. Pour ground coffee into the filter . 2 . Slide the brew cone into place. When pushed in against the stop, the brewcone fits into the slide rails and centers it under the sprayhead. 3 . Place a clean coffee decanter on the warmer plate. 4 . T o start brewing, push in the moment ary brew switch, loca[...]
-
Page 5
MAINTENANCE & CLEANING OF BREWER Regular and preventive maintenance is essential in keeping your Alpha system looking and working like new. CAUTION When cleaning your Alpha System, do not use cleansers, bleach liquids, powders or any other substance that contains chlorine. These products promote corrosion and will pit the stainless steel. USE O[...]
-
Page 6
[ 4 ] POSSIBLE CAUSE SOLUTION Water line turned off or water filter clogged. Coil on Water Inlet Valve has burnt out. Grounded Water Level Probe. Defective Liquid Level Control (LLC) board. PROBLEM: Water does not flow into heating tank... ANY SERVICE DONE ON THIS UNIT MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. TROUBLE SHOOTING Disconnect[...]
-
Page 7
[ 5 ] POSSIBLE CAUSE SOLUTION Thermostat turned off. Burned out Heating Element. Check the thermostat to make sure stem is turned all the way to the right. If thermostat is on (closed) you should read 110/120 volts at the element terminals. Voltage present at these points but no heat, indicates the element is burned out. Replace it. PROBLEM: water [...]
-
Page 8
[ 6 ] Figure 3. Illustrated Parts List, Main View (Alpha 3X Shown). ALPHA 3X ILLUSTRA TED P ARTS THIS FIGURE (AND FIG. 4.) SHOW THE ALPHA 3X. ALL OTHER ALPHAS ARE SIMILAR EXCEPT WHERE DETAILED (FIG. 5, 6 & 7).[...]
-
Page 9
Figure 4. Illustrated Parts List, Detail Bubbles (Alpha 3X Shown). ALPHA ILLUSTRA TED P ARTS [ 7 ] 29[...]
-
Page 10
[ 8 ] ALPHA Part s List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 37 38 39 40 41 43 44 45 46 48 49 DESCRIPTION PART NUMBER INDEX NUMBER WC-38310 WC-6205 WC- 517 WC-4505 WC-2977 WC-4320 WC-2922 WC- 604 WC-4436 WC-3958 WC- 130 WC- 129 WC- 128 WC- 202 WC-1809 WC-1806 WC-5477 WC-4213 WC-2936 WC-1411[...]
-
Page 11
ALPHA 3X Part s List [ 9 ] DESCRIPTION INDEX NUMBER 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 70 71 72 PROBE, WATER LEVEL . . . . . . . . . . . . . . . . . . . . . FITTING, 1/8" HEX FOR WATER LEVEL PROBE . . . . . . SHOCK GUARD FOR HEATING ELEMENT . . . . . . . . . . WASHER, 9/16" I.D. TEFLON . . . . . . . . . . . . . . . .[...]
-
Page 12
[ 10 ] ALPHA 3XR & ALPHA 3XL THIS FIGURE ILLUSTRATES THE DIFFERENCES BETWEEN THE ALPHA 3XR/L AND THE ALPHA 3X. THE ALPHA 3XR/L HAS A PLAIN TOP COVER AND A WIDE BOTTOM COVER. THE LABELING ON THE SWITCH PANEL IS ALSO DIFFERENT. Figure 5. Illustrated Parts, Alpha 3XR & 3XL. ALPHA 3XR ALPHA 3XL 64 65 66 8[...]
-
Page 13
ALPHA 2X [ 11 ] THIS FIGURE ILLUSTRATES THE DIFFERENCES BETWEEN THE ALPHA 2X AND THE ALPHA 3X. THE ALPHA 2X HAS ONLY TWO WARMERS, A DIFFERENT TOP COVER AND TWO WARMER SWITCHES ON THE SWITCH PANEL. Figure 6. Illustrated Parts, Alpha 2X. 68 67 THE ALPHA 6X IS BASICALLY AN ALPHA 3XR AND AN ALPHA 3XL LINKED TOGETHER. THIS FIGURE ILLUSTRATES THE DIFFERE[...]
-
Page 14
APPVD. WIRES HZ VOLTS DATE PHASE AMPS WATTS 8/4/97 2 1 3 2 1 3 2 1 3 2 1 3 T4 T3 T2 T1 OFF/ON SWITCH BREW SWITCH TIMER 2 B 6 A WHT L LIQUID LEVEL CONTROL THERMOSTAT BLK RED BLK 2 1 3 DUMP VALVE REV. C Single 2+GND 60 120 BLK DRWN. WIRING DIAGRAM BOTOM WARMER SWITCH BLK WHT WHT PWR CORD BLK GRN WHT [...]
-
Page 15
[ 13 ] WIRES HZ VOLTS WD-AL2X-10 PHASE AMPS WATTS MODEL 120 2+GND 14.2 60 1700 Single ALPHA 2X -10 DRWN. CHKD. APPVD. 8/4/97 DATE C REV. THERMOSTAT PROBE BLK BLK WHT GRN PWR CORD WHT BLK BLU RED RED GRY L WHT BLK 2 1 3 T4 T3 T2 T1 WATER LEVEL CONTROL YEL ST BLK WHT BLK YEL 1450W HEATING ELEMENT WHT WHT WHT WHT WHT TIMER RED 2 B [...]
-
Page 16
[ 14 ] BLU RED[...]
-
Page 17
THIS P AGE INTENTIONALL Y LEFT BLANK[...]
-
Page 18
Product W arranty Information The Wilbur Curtis Company certifies that its products are free from defects in material and workmanship under normal use. The following limited warranties and conditions apply: 3 Y ears, Parts and Labor , from Original Date of Purchase on digit al control boards . 2 Y ears, Parts, from Original Date of Purchase on all [...]