Williams 2903512 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Williams 2903512, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Williams 2903512 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Williams 2903512. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Williams 2903512 should contain:
- informations concerning technical data of Williams 2903512
- name of the manufacturer and a year of construction of the Williams 2903512 item
- rules of operation, control and maintenance of the Williams 2903512 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Williams 2903512 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Williams 2903512, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Williams service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Williams 2903512.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Williams 2903512 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation Instructions and Owner’s Manual Direct-Vent Wall Furnace - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GA S • Open all windows. • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in y[...]

  • Page 2

    Table of Contents General Information and Technical Data Instructions to Installer ………………………………………………………………… ………………………………………… ………1 Safety and General Warnings …………………… …………………………………… ……………………………?[...]

  • Page 3

    Safety Rules and General Warnings DO NOT OPERATE THIS FURNACE WI THOUT THE FRONT P ANEL INSTALLED • Due to high temperatures, the furnace should be located out of traffic and away from combustible materials such as furniture and draperies . • More frequent cleaning may be requi red due to excessive lint from carpeting, bedding material s, etc. [...]

  • Page 4

    Some Points to Remember • Learn to recognize the odor of LP Gas. Your local LP Gas Dealer ca n give you a ”Scratch and Sniff” pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP Gas has a weak or abnorm al odor, call your LP Gas Dealer. • If you are not qualified, do not light pilot lights, perform se[...]

  • Page 5

    Installation Installation should be done by a QU ALIFIED SERVICE TECHNICIAN. The furnace must be located on an o utside wall. WARNING: For the installati on of this furnace, the following items must be used as a v ent air intak e system: Wall Installation Minimum clearances from combustible materials: External Vent Cap • Furnace to the top surfac[...]

  • Page 6

    A. Clearance above grade, verand a, porch, deck or balcony 12-inches (30 cm ) minimum. (3) B. Clearance to window or do or that may be opened 12- inches (30 cm) minimum. (3) C. Clearance to permane ntly closed window (minimum 12- inches (30 cm) recomme nded to prevent condensation on wind ow. D. Vertical clearance to ventilated soffit located above[...]

  • Page 7

    Outside Location for Vent Terminal Upon delivery, check to make sure the p ackaging has not been damaged. 1. Remove the furnace from box/packaging taking care not to damage the paper template to be used to mark the holes for mounting the furnace. 2. After marking the appropri ate holes using the above mentioned template, make a 2-inch diameter hol [...]

  • Page 8

    12. When the inside installation is com plete, proceed to the out side location of the aluminium vent cap on the external wall. The vent cap should perfectly match the pipe end. Mark the lo cation of the three holes for the scre w anchors. (Figure 7) The flue grid must be vertical. 13. Remove the vent cap and drill all the necessary hole s (diame t[...]

  • Page 9

    Gas Conversions Converting to another gas type mu st be performed by a qualified service technician. If the type of th e gas supplied to the dwelling is not the same type as your furnace (natural or LPG gas), it must be converted. It will be necessary to do the following: 1. Change nozzle. a. Remove the screw indicated to the right. 2. Without remo[...]

  • Page 10

    Gas Supply Check all local codes for requireme nts, especially for the size and type of gas supply line req uired. On natural gas lines less than 15” (380 mm) long, use 1/2” tube; on longer runs, use 3/4” ir on tube or equal. On LP gas lines, consult LP ga s supplier. Installing a New Main Gas Shutoff Valve Each appliance should have its own [...]

  • Page 11

    First Firing of the Furnace Start the furnace following the instructio ns given in the “Opera ting Instructions“. The initial pilot lighting may be difficul t due to air trapped in the gas lines. During initial firing of the furnace, re sidual manufacturin g grease will bake-out and smo ke will occ ur which is not a health danger. To prevent nu[...]

  • Page 12

    Electrical Wiring FLAME VIEW LAMP (GREEN LAMP) SF GAS VALVE 1 (SAFETY SHUTTER) EV LOCK-OUT LAMP (RED L AMP) SB EV1 CURRENT TRANSF ORMER 120-24 V TR HI-LO FLAME OPERATOR (*) EV2 RESET AND SUMMER – WINTER SWI TCH (*) Z1 FAN MOTOR (n. 2 MOTORS ON 8001/ 8002) M HI-LO FLAME AND FAN SPEED SWITCH (*) Z2 OVERHEAT THERMOSTAT M1 MANUAL – PROGRAM MODE SWI[...]

  • Page 13

    Operating Instructions Before operating the furnace, read carefully all wa rnings and safety information i n this manual. A . T hi s app li anc e do es no t ha v e a pi l o t w hi c h m us t F ol l ow t he ga s sup pl i e r ' s i ns t r uc ti ons . be l i g hted by m eans of th e pi ez o ig ni t er i ns t al le d - If y o u c ann o t r eac h y[...]

  • Page 14

    W HA T T O DO IF T HE RE D L AM P IS L IT T hi s appl i anc e has an e le c t r o ni c fl am e s uper v is io n de v i ce. If t he f l am e di s a ppea r s th e ga s f lo w w il l be aut om ati c al l y s h ut o ff an d th e r ed lam p wi l l l i g ht i ns tea d of th e gr ee n on e. T he a ppl i anc e w i l l a ttem pt to r eli gh t i f yo u do ON[...]

  • Page 15

    Servicing All servicing activities must be carried out by a qualified se rv ice technicial or a service agency. The home own er may not service the furnace. The home owner must rea d this secti on to be informed of the periodic ma intenance and che cks the required. All servicing (except on vent sys tem) must be carried out with the external casing[...]

  • Page 16

    Annual Maintenance Requirements 1. Clean fan blades. 2. Clean air blower. 3. Check and clean sili cone red pipes. 4. Check air flow switch. 5. Clean and check exhaust flue pipe a nd air intake pipe. Check red O-Ring G asket (NRNG003). If it is damaged, replace it. 6. Check for ga s leaks on all conne ctions. 7. Check and adjust gas pre ssure. Gas i[...]

  • Page 17

    Programmable Timer The programmable timer allows precise operating an d timing control and is standard on this furnace. (Figure 10) Overview The programmable timer has the following feature s: • Long life lithium battery • Daily and weekly programs • One minute minimum switching time • Quick progressi on • Sixteen programs (8 on and 8 off[...]

  • Page 18

    Setting and Adjustment 1 2 3 4 5 6 7 0 :00  1 2 3 4 5 6 7 E EE  1 2 3 4 5 6 7 0 :00  1 2 3 4 5 6 7 0 :00  1 2 3 4 5 6 7 0 :00  ☼ 1 Initial Conditions A. Set the Setting/Regulator switch (Figure 10-B) in RUN position (ce nter). Press the Reset button R. The display will flash. B. With the Setting/Regulator switch sele ctor in positi[...]

  • Page 19

    D. Press the Day Setting, (1……7, Figure 11-D) bu tton to program another day or block of days. E. To set further programs repeat steps item B through D above. NOTE: When the same ON and O FF times are desired for different days of the week, the setting procedu re may be simplified. • 1-2-3-4-5 (from Monday through Friday) • 1-2-3-4-5-6 (fro[...]

  • Page 20

    Troubleshooting Starting Sequence (Electrical) Step 1 1. Check L1 – L2 (Supply 120 V, 60 Hz) 2. Check M9 (Main fuse) Troubleshooting Step 1 Point 1 (L1-L2) No voltage (120 V). Check the electrical supply line, wirin g and connectio ns. Point 2 (M9) Fuse damaged. Check the electrical supply line and repla ce the fuse. Summer Mode Step 2 3. Check Z[...]

  • Page 21

    Troubleshooting Step 3 Point 5 (Z1) Z1 is open and no ignition. Check wiring and conn ections. If everything is okay, replace the switch. Point 7 (M2) M2 is closed and fan thermostat temperature lower than 104 °F. Check wiring and connections. If they are okay, replace the thermostat. Step 4 8. Check Z9 (Roo m thermostat). Close the thermostat wit[...]

  • Page 22

    Point 13 (TR) No inlet voltage (120 V). Check 5 pole conne ctor and control box. If everything is okay, replace the connector . No outlet voltage (24 V) during ignition. Check wiring and conn ections. If everything is okay, replace the transformer. Point 14 (EV1) Valve closed during ignition (Z2 down ). Check wiring, connections and voltage. If eve[...]

  • Page 23

    Replacement Parts TR – 120/24V Transform er Part Number: JTRS017 Ignition Control Box Part Number: JCNT019 NP – Pressure Switch Part Number: JPRS009 Z9 – Room Thermostat Part Number: JTLT005 Z1 – Reset and Summer/Winter Switch Part Number: NTST000 Z8-Z3 – Timer and Manual - Program Mode Switch Part Number: N19800202 Z2- Hi-Lo Flame and Fa[...]

  • Page 24

    RP8 : Flame Sensor Part Number: JLTT015 RP7: Spark Igniter (2 piec es) Part Number: JLTT023 S – Combustion Blower Motor Part Number: JMTR020 M1 – Overheat Thermostat Part Number: JTRM006 M2 - Fan Thermostat Part Number: J12301018 Fan Blades (4 Pieces) Part Number: VVNT003-VVNT002 M - Fan Motor Part Number: (2 Pieces) JMTR018 Williams Furnace Co[...]