Go to page of
Similar user manuals
-
Ventilation Hood
Wolf Appliance Company L342212
16 pages 0.25 mb -
Ventilation Hood
Wolf Appliance Company Pro Wall
24 pages 0.51 mb -
Ventilation Hood
Wolf Appliance Company PW362718R
8 pages 0.37 mb -
Ventilation Hood
Wolf Appliance Company PW362418
8 pages 0.37 mb -
Ventilation Hood
Wolf Appliance Company PW422210
2 pages 0.17 mb -
Ventilation Hood
Wolf Appliance Company PL401912
2 pages 0.27 mb -
Ventilation Hood
Wolf Appliance Company PI423418(R)
8 pages 0.34 mb -
Ventilation Hood
Wolf Appliance Company PI543418
8 pages 0.34 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Wolf Appliance Company PW302210R, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Wolf Appliance Company PW302210R one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Wolf Appliance Company PW302210R. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Wolf Appliance Company PW302210R should contain:
- informations concerning technical data of Wolf Appliance Company PW302210R
- name of the manufacturer and a year of construction of the Wolf Appliance Company PW302210R item
- rules of operation, control and maintenance of the Wolf Appliance Company PW302210R item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Wolf Appliance Company PW302210R alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Wolf Appliance Company PW302210R, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Wolf Appliance Company service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Wolf Appliance Company PW302210R.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Wolf Appliance Company PW302210R item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Dimensions in parentheses are in millimeters unless otherwise specified. 9/07 1 Planning Inf ormation Pro Lo w-Pr ofile W all V entilation Hood MODEL PW302210(R) Model PW302210 Model PW302210R Rail Option W olf Pro wall hoods pr ovide the ultimate in ventilation. With standard elements like heat sentry and dual setting halogen lighting, W olf elev [...]
-
Page 2
2 Dimensions in parentheses are in millimeters unless otherwise specified. Unit dimensions may v ary by ± 1 / 8 " (3). Planning Inf ormation Pro Lo w-Pr ofile W all V entilation Hood MODEL PW302210(R) FEA TURES 30" (762) wide wall ventilation hood with classic stainless steel finish Rail option wall hoods (R) come with a classic stainles[...]
-
Page 3
3 Dimensions in parentheses are in millimeters unless otherwise specified. Planning Inf ormation Pro Lo w-Pr ofile W all V entilation Hood MODEL PW302210(R) SPECIFICA TIONS Overall Width of Hood 30" (762) Overall Height of Hood 10" (254) Overall Depth of Hood 22" (559) (including rail) 24" (610) Internal Blower Option 500 CFM In[...]
-
Page 4
4 30" TO 36" (762 – 914) T O COUNTERT OP 22" (559) DEPTH OF HOOD 30" (762) WIDTH OF HOOD 30" TO 36" (762 – 914) T O COUNTERT OP 10" (254) HEIGHT OF HOOD E 6" (152) 5" (127) LOCA TION OF ELECTRICAL NO TE: Pro low-profile hoods ha ve an adjustab le discharge. DIMENSIONS Overall Width of Hood 30" ([...]
-
Page 5
5 Dimensions in parentheses are in millimeters unless otherwise specified. Planning Inf ormation Pro Lo w-Pr ofile W all V entilation Hood MODEL PW302210(R) INST ALLA TION NOTES Refer to the illustrations and specifications for overall dimensions and installation specifics. Wolf Pr o wall ventilation hoods are recom- mended for use with any Wolf co[...]
-
Page 6
6 Dimensions in parentheses are in millimeters unless otherwise specified. Planning Inf ormation Pro Lo w-Pr ofile W all V entilation Hood MODEL PW302210(R) Ducting for Pro low-profile wall hoods. DUCTWORK INST ALLA TION THROUGH ROOF 22" (559) DEPTH OF HOOD 10" (254) ROUND DUCT SOFFIT OR CABINET OR DUCT CO VER VERTICAL DISCHARGE 17 3 / 4 [...]
-
Page 7
7 Dimensions in parentheses are in millimeters unless otherwise specified. Unit dimensions may v ary by ± 1 / 8 " (3). Planning Inf ormation Pro Lo w-Pr ofile W all V entilation Hood MODEL PW302210(R) WOLF BLOWER ASSEMBLIES A ventilation system must include a blower assembly . Wolf ventilation hoods are shipped without the blower assembly . A[...]
-
Page 8
8 Dimensions in parentheses are in millimeters unless otherwise specified. Planning Inf ormation Pro Lo w-Pr ofile W all V entilation Hood MODEL PW302210(R) PRO VENTILA TION CFM RECOMMENDA TIONS PRO VENTILA TION BLOWER OPTIONS Pro Lo w-Prof ile W all Hoods Blow er Description Blow er Number W all Hood Models 500 CFM Internal WBLOWER-50INT (810991) [...]