Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Yamaha Rio1608-D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Yamaha Rio1608-D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Yamaha Rio1608-D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Yamaha Rio1608-D should contain:
- informations concerning technical data of Yamaha Rio1608-D
- name of the manufacturer and a year of construction of the Yamaha Rio1608-D item
- rules of operation, control and maintenance of the Yamaha Rio1608-D item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Yamaha Rio1608-D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Yamaha Rio1608-D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Yamaha service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Yamaha Rio1608-D.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Yamaha Rio1608-D item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
R Remote O peration Ma nual 1 R Rem ote Operation Manual Thank y ou fo r choo sing a Y amaha prod uct. This o perat ion man ua l expl ains set u p and use of "R Re mote, " a W indo ws ap plicat ion t hat let s yo u make head amp (subsequen tly "HA") settings for the Rio3224 - D/R io1 608 - D/Ri8 - D (subse quent l y "R seri[...]
-
Page 2
R Remote O peration Ma nual 2 Contents ■ System Requirements ............................................................................................................................... 3 ■ Setup ...................................................................................................................................................[...]
-
Page 3
R Remote O peration Ma nual 3 ■ Sy st em Require ments In order to use R Remote, y ou'll need th e following items. ● A W indows co mp uter eq uipped with t he fo llow ing c onditio ns: OS W i ndows 7 SP1 Home Premium or l at er , W indo ws 8, W indows 8 .1 CPU Intel Co re i3 /i5 or higher HDD 120 MB or more Con nec tor An Etherne t connec[...]
-
Page 4
R Remote O peration Ma nual 4 Inst all ing the R Remo te The in stalla tion p roc edu re is as f ollow s. 1. Logo n to W indow s wit h administe r acc ount . 2. After decom pressing th e downloade d file, double - cl ick “set up.exe” in the decom pressed file locat ion. The R Remote setu p wizard wi ll ap pear . ・ The “U ser Acc ount C ontr[...]
-
Page 5
R Remote O peration Ma nual 5 Setting s on th e R ser ies uni ts When usi ng R Remot e to operat e an R serie s unit, set the DIP switches an d [UNIT ID ] rotary switc h of the unit, taking n ote of the following settings . ・ Set the UNIT ID in t he ran ge of 1 to 8. R R emote will not d etect units with a setting o f 0 or 9 or higher . ・ Set t[...]
-
Page 6
R Remote O peration Ma nual 6 Conne ct the co mputer and R s eries unit s Use an Et hernet cab le to c onnec t the com puter and the R ser ies un its. If you se lecte d DAIS Y CHAI N in “ Sett ings on t he R series u nits " on the previou s page, connect t he Dante connectors of th e R serie s units in a da isy chai n to the comp ute r . If [...]
-
Page 7
R Remote O peration Ma nual 7 TC P/IP Set tin gs Make T CP/IP setting s fo r the com puter as fol lows . 1. Acce ss the C ontro l Panel, then cli ck or do uble - click [Network and Sharing Center] or [V i ew network status and tasks]. The “Net work an d Shar ing Ce nter” is dis p laye d. 2. Click [Manage network connection] or [Ch ange adapter [...]
-
Page 8
R Remote O peration Ma nual 8 Use Dant e Controller or t he CL seri es cons ole t o speci fy the routing Y ou'll use Dant e Contro ller or the CL series co nsol e to spec ify t he rout ing. If you're using Da nte Controller to specify th e routing, refer to " Dante Cont roller User ’ s Guid e." If you're usi ng a CL serie[...]
-
Page 9
R Remote O peration Ma nual 9 ■ Operating R Remote When you start R Remote, the "Network Setup" dialog b ox may appear , allowing you to se lect the comput er' s netwo rk card tha t wil l be use d for com municat ion wit h the R series units. If thi s appe ars, click t he netw ork card t hat is c onnect ed to the R s eries un it, a[...]
-
Page 10
R Remote O peration Ma nual 10 Main sc reen Here yo u can m ake setti ngs for t he H A of the R ser ies un its. ① Display select buttons Click on e of these but ton s to view the co rre spond ing R serie s unit a t the ri ght. Up to two insta nces of R Rem ote ca n be simultan eou sly co nnect ed to a n R series u nit. For e xa mple , this wo uld[...]
-
Page 11
R Remote O peration Ma nual 11 ④ [SYSTEM] indicator /[SYNC] ind ica to r Indic ates th e stat us of the R ser ies un it or the Da nte stat us. For more ab out this in dicat ion, refer to "Messages" in the owner ’ s m anual of R se rie s . ⑤ Conne ctor i ndex Indicates th e range of conn ect or number s corr esp ondi ng to the HA set[...]
-
Page 12
R Remote O peration Ma nual 12 “ I/O Device Ed it ” dialog box Here yo u can view and e dit det aile d HA settings for the R series un it. This appear s whe n you click a connector index in th e m ain scr een. The t oolba r also show s the UNI T ID o f the R seri es unit. T o clo se the dial og box , clic k the [ x] button lo cate d in the u pp[...]
-
Page 13
R Remote O peration Ma nual 13 “ Netw ork Setup ” dialog box Here you can select t he netw ork interface ca rd of the com p uter that wi ll be used to comm u nicat e with the R ser ies (s ubsequent ly c alled “t he net work c ard”). ① Networ k card li st Select the ne twork car d that w ill be u sed to comm unicat e wit h R series . ② [[...]
-
Page 14
R Remote O peration Ma nual 14 “ R Seri es Infor mation ” dial og box This display s informati on about the R ser ies un its that are co nnected. Here y ou ca n also c hange the connec tion st atus of each R series unit. ① [ID] list Click t he UN IT ID of the R serie s unit whos e informatio n you want to view . ② [Information] disp lay a r[...]
-
Page 15
R Remote O peration Ma nual 15 ■ Uninst alling the sof tware(Removing the appl ication) Use “ Co ntrol Panel ” to uni nstall t he sof twar e. In Contr ol Panel, clic k [Program s and funct ions] o r [Uninstal l a program], then s elect the item yo u want to unin stall, and cl ick [Unin stall or chang e]. A dialog box will a ppear; follow th e[...]
-
Page 16
R Remote O peration Ma nual 16 ■ T r oubleshoot ing Problem Possi ble cau se Act ion R serie s unit is not det ected The R se ries un it's power switch is not on T urn the powe r switc h on. The R se ries un it's DIP sw itch setti ngs ar e incor rect Make the same settin gs as shown in o ne of the DIP switch setting examples of "Se[...]
-
Page 17
R Remote O peration Ma nual 17 Audio is not input / Inp ut level is low HA gain is not a t an ap propriate level Set the HA gain to a n appropriate lev el. The external dev ice is no t outputting a si g nal Output a sig nal fr om the sourc e device and make sure that th e SIG in dicat ors on t he appro priate chan nels w il l light . A conde nser m[...]