Go to page of
Similar user manuals
-
Air Conditioner
York R-22
4 pages 0.08 mb -
Air Conditioner
York FRCS024
16 pages 0.52 mb -
Air Conditioner
York YCJD18 THRU 60
18 pages 0.56 mb -
Air Conditioner
York DNP060
36 pages 2.54 mb -
Air Conditioner
York 66386-YUM-C-1011
6 pages 0.24 mb -
Air Conditioner
York TCGF24 THRU 60
28 pages 0.4 mb -
Air Conditioner
York DJ 048
48 pages 0.68 mb -
Air Conditioner
York H1CE150
16 pages 0.71 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of York 12 SEER H*RC018 THRU 060, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York 12 SEER H*RC018 THRU 060 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of York 12 SEER H*RC018 THRU 060. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of York 12 SEER H*RC018 THRU 060 should contain:
- informations concerning technical data of York 12 SEER H*RC018 THRU 060
- name of the manufacturer and a year of construction of the York 12 SEER H*RC018 THRU 060 item
- rules of operation, control and maintenance of the York 12 SEER H*RC018 THRU 060 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York 12 SEER H*RC018 THRU 060 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York 12 SEER H*RC018 THRU 060, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York 12 SEER H*RC018 THRU 060.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the York 12 SEER H*RC018 THRU 060 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
TECHNICAL GUIDE SPLIT -SYSTEM AIR CONDITIONERS 12 SEER MODELS: H*RC018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*RC036S(25,4 6) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) Due to continuous prod uct improvement, specific ations are subject to change without notice. Visit u s on the web at www .york.com for the most up-to-date techni cal information . A[...]
-
Page 2
036-21137-004 Rev. C (0505) 2 Unitary Products Group Physical and Electrical Dat a - 1 Phase MODEL H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC 042S06 H2RC048S06 H4RC060S06 Unit Supply V oltage 208/230 – 1 – 60 Normal V oltage Range 187 to 252 Minimum Circuit Ampacity 1 10.1 14.1 16.5 19.7 26.2 28.5 37.5 Max. Overcurrent Device Amps 2 15 25[...]
-
Page 3
036-21137-004 Rev. C (0505) Unitary Products Group 3 Additional R-22 Charge / Orifice Size for V arious Matched Systems - 1 Phase Outdoor Unit H2RC018S06 H2RC024S06 H2RC030S06 H 2RC036S06 H2RC042S06 H2R C048S06 H4RC060S06 Unit Orifice (s ) 1 53 59 63 73 78 87 – Factory R-22 Charge, lbs-oz. 4 - 9 4 - 7 5 - 8 5 - 3 6 - 13 7 - 7 8 - 15 Indoor Coil 5[...]
-
Page 4
036-21137-004 Rev. C (0505) 4 Unitary Products Group PROCEDURES: 1. Unit factory charge list ed on the uni t n ameplate includes ref rig erant for th e cond enser , the smallest evaporator and fo r 15 f eet of interconnecting line tubing. 2. V erify the orif ice size and additional charge required for s pecific evaporator coil in t he system using [...]
-
Page 5
036-21137-004 Rev. C (0505) Unitary Products Group 5 PROCEDURES: 1. Unit factory charge list ed on the uni t nameplate includes ref rig erant for th e condenser , the smallest evaporator and for 15 f eet of interconnecting l ine tubing. 2. V erify the orifice size and additi onal char ge required for sp ecific evaporator coil in the system using th[...]
-
Page 6
036-21137-004 Rev. C (0505) 6 Unitary Products Group - = Not applicable. COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRIC 2 HEA T KW W RA TED CFM NET MBH SEER W/O TXV SEER WITH TXV 3 EER TOT AL SENS. 1 PH 12 SEER AC WITH N1AH / G2FD H2RC018S06 N1AHB0806 2,5,8,10 17 G2FD024(S, H)17 600 19.6 13.2 1[...]
-
Page 7
036-21137-004 Rev. C (0505) Unitary Products Group 7 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) WR A T E D C F M NET MBH SEER W/O TXV SEER + TXV 1 EER TOT AL SENS. H2RC018S06 525 675 14,17 G1F A024S14,17 600 19.2 13.0 12.00* 12.00 1 1.35 14 G1HA024H14 600[...]
-
Page 8
036-21137-004 Rev. C (0505) 8 Unitary Products Group H2RC036S06 1050 1350 14 G1F A036S14 1200 33.6 23 .4 1 1.50* 1 1.50 10.60 17,21 G1F A036S17,21 1200 33.0 23.0 1 1.25 * 1 1.25 10.45 17 G1F A048S17 1200 35.0 24 .4 12.00* 12.00 10.90 21 G1F A048S21 1200 34.0 25 .2 12.00* 12.00 10.70 14 G1HA036H14 1 150 33.5 23 .8 12.00* – 10.75 14 G1HA036H14 1 15[...]
-
Page 9
036-21137-004 Rev. C (0505) Unitary Products Group 9 *Requires 2FD Blower T ime Delay unless a st andard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace mat ch-up. H2RC048S06 1375 1775 17 G1F A048S17 1575 45.5 34.1 12.00* 12 .00 1 1.00 21 G1F A048S21 1575 46.5 34.9 12.00* 12 .00 1 1.00 21,24 G1F A060S21,24 1575 [...]
-
Page 10
036-21137-004 Rev. C (0505) 10 Unitary Products Group COOLING CAP ACITY - With V ariable Spe ed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM NET MBH SEER W/O TXV SEER + TXV 2 EER TOT AL SENS. 1 PH 12 SEER AC - V ARIABLE SPEED 3 H2RC018S06 P1DUA12V/PV8A12****UH G1F A024 S14 14 600 19.6 13.4 – 13.00 12.55 P1DU[...]
-
Page 11
036-21137-004 Rev. C (0505) Unitary Products Group 11 H2RC048S06 P1DUC20V/PV8C20****UH G1F A048S21 21 1 610 46.5 34.9 – 12.10 1 1.15 P1DUC20V/PV8C20****UH G2FD048(S,H)21 21 1610 46.5 34.9 – 12.25 1 1.05 P1XDD20V G2FD048(S,H)24 24 1610 47.0 35.4 – 12.40 1 1.00 P1XUC16V G1F A048S21 21 1480 46.0 34.4 – 12.10 10.90 P1XUC16V G2FD048(S,H)21 21 14[...]
-
Page 12
036-21137-004 Rev. C (0505) 12 Unitary Products Group All dimensions are in inches. T hey are subject to change without notice. Certified dimensi ons will be provided upon request. ACCESSORIES* Refer to Price Manual for specific model numbers. Hard St art Kit - Provides increased starting torque for areas with low voltage. Compressor Blanket - Desi[...]
-
Page 13
036-21137-004 Rev. C (0505) Unitary Products Group 13 TYPICAL INST ALLA TION TYPICAL FIELD WIRING - 1 Phase Application TYPICAL FIELD WIRING - 3 Phase Application MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE 60” OVERHEAD CLEARANCE 10” CLEARANCE COIL AREA WEA THERPROOF DISCONNECT SWITCH THERMOST A T TO FURNACE OR AIR HANDLER TERMINAL BLOCK[...]
-
Page 14
036-21137-004 Rev. C (0505) 14 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per degree abo ve the listed temperature and decre ases by 1060 BTUH per 1000 CFM per[...]
-
Page 15
036-21137-004 Rev. C (0505) Unitary Products Group 15 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per[...]
-
Page 16
036-21137-004 Rev. C (0505) 16 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per degree abo ve the listed temperature and decre ases by 1060 BTUH per 1000 CFM per[...]
-
Page 17
036-21137-004 Rev. C (0505) Unitary Products Group 17 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per[...]
-
Page 18
036-21137-004 Rev. C (0505) 18 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per degree abo ve the listed temperature and decre ases by 1060 BTUH per 1000 CFM per[...]
-
Page 19
036-21137-004 Rev. C (0505) Unitary Products Group 19 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per[...]
-
Page 20
036-21137-004 Rev. C (0505) 20 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per degree abo ve the listed temperature and decre ases by 1060 BTUH per 1000 CFM per[...]
-
Page 21
036-21137-004 Rev. C (0505) Unitary Products Group 21 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per[...]
-
Page 22
036-21137-004 Rev. C (0505) 22 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per degree abo ve the listed temperature and decre ases by 1060 BTUH per 1000 CFM per[...]
-
Page 23
036-21137-004 Rev. C (0505) Unitary Products Group 23 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per[...]
-
Page 24
Subject to change without notice. Printe d in U.S.A. 036-21137-004 Rev. C (0505) Copyright © by Y ork International Corp. 2005. All rights reserved. Supersedes: 036-21137-004 Rev. B (0105) Unitary 5005 Norman Product s Y ork O K Group Drive 73069 MA TCHING INDOOR COMPONENTS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW [...]