Go to page of
Similar user manuals
-
Air Conditioner
York D3HH 024
16 pages 0.69 mb -
Air Conditioner
York D7CG 036
20 pages 0.38 mb -
Air Conditioner
York D1EE 060
16 pages 0.7 mb -
Air Conditioner
York LD11556
12 pages 0.83 mb -
Air Conditioner
York D2EE 036
16 pages 0.7 mb -
Air Conditioner
York STELLAR PLUS H4DH018 THRU 060
20 pages 0.57 mb -
Air Conditioner
York PREDATOR R-410A
128 pages 10.91 mb -
Air Conditioner
York H*RE024
16 pages 0.56 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of York D2EE 036, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York D2EE 036 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of York D2EE 036. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of York D2EE 036 should contain:
- informations concerning technical data of York D2EE 036
- name of the manufacturer and a year of construction of the York D2EE 036 item
- rules of operation, control and maintenance of the York D2EE 036 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York D2EE 036 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York D2EE 036, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York D2EE 036.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the York D2EE 036 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
GENERAL YORK Model DEE units are single package air conditioners designed for outdoor installation on a rooftop or a slab. Electric heaters are available as field-installed accessories. The units are completely assembled on rigid, permanently attached base rails. All piping, refrigerant charge, and electrical wiring is factory-installed and tested.[...]
-
Page 2
035-12046-003-A-0204 2 Unitary Products Group General ................................................................................ 1 Inspection ............................................................................ 1 Reference ............................................................................ 1 Approvals ........................[...]
-
Page 3
LIMIT ATIONS These units must be installed in accordance with the current edition of the following national and local safety codes: In USA: 1. National Electrical Code ANSI/NFP A No. 70. 2. Local electric utility requirements. In Canada: 1. Canadian Electrical Code C22.1. 2. Canadian Installation Codes CAN/CGA-B149.1 and .2. Refer to T able 1 for U[...]
-
Page 4
kept clean or replaced with same size and type. Dirty filters will reduce the capacity of the unit and will result in frosted coils or safety shutdown. Minimum filter area and required sizes are shown in T able 2. CONDENSA TE DRAIN Plumbing must conform to local codes. Use a sealing compound on male pipe threads. Install a condensate drain line fro[...]
-
Page 5
All direct-drive units with 460 and 575 voltage are shipped with the wire labeled #1 16 connected to the “HIGH” speed tap on the blower motor . If the medium speed is required, connect wire #1 16 to the “MED” speed tap and the blue motor lead to the “HIGH” speed tap. If the low speed is required, connect wire #1 16 to the “LOW” spee[...]
-
Page 6
10. T o check that the damper blades move smoothly without binding, carefully turn the minimum position adjusting screw fully clockwise and then energize and de-energize terminals “R” to “G”. With terminals “R” to “G” energized, turn the minimum position screw counterclockwise until the desired minimum position has been attained. 1 [...]
-
Page 7
035-12046-003-A-0204 Unitary Products Group 7 FIG. 5 - DIMENSIONS & CLEARANCES - 3 - 5 TONS DUCT COVERS - Units are shipped with all air duct openings covered. For side duct applications; 1.Remove and discard the supply and return air duct covers. 2.Connect ductwork to duct flanges on the rear of the unit. For bottom duct applications; 1. Remov[...]
-
Page 8
Install the bracket on the left hand side of the unit as shown in Figure 5. Several existing screws at the top of the unit and one screw approximately midway down from the top will be used for mounting the bracket. Screws should be loosened only - NOT REMOVED. Matching holes in the bracket have elongated keyways allowing easy installation. Re-tight[...]
-
Page 9
035-12046-003-A-0204 Unitary Products Group 9 T ABLE 4 - SUPPL Y AIR PERFORMANCE - 3 & 4 TON w/Belt-Drive Blower UNIT SIZE (MBH) AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM W atts RPM Watts RPM W atts RPM Watts RPM W atts RPM Watts RPM W atts 048 2000 843 860 880 925 919 1005 956 1065 993 1 145 [...]
-
Page 10
035-12046-003-A-0204 10 Unitary Products Group T ABLE 5 - SUPPL Y AIR PERFORMANCE - 5 TON w/Belt-Drive Blower UNIT SIZE (MBH) AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM W atts RPM Watts RPM W atts RPM Watts RPM W atts RPM W atts RPM Watts 060 2500 1059 1560 1077 1590 1095 1630 1 1 14 1650 1 134 166[...]
-
Page 11
035-12046-003-A-0204 Unitary Products Group 11 EXTERNAL ST A TIC PRESSURE DROP DESCRIPTION RESIST ANCE, IWG CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Economizer 1, 3 0.07 0.08 0.09 0.1 1 0.13 0.15 0.17 0.20 0.23 0.26 0.30 Electric Heaters 1 5 - 15 KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 0.19 0.22 20 - 30 KW 0.06 0.07 0.08 0[...]
-
Page 12
The heaters are wired for a single point power supply . Power supply need only be brought into the single point terminal block and thermostat wiring to the low voltage terminal strip located in the upper portion of the unit control box. Fuses are supplied, where required, by the factory . Some KW sizes require fuses and others do not. Refer to the [...]
-
Page 13
HEA T ANTICIP ATOR SETPOINTS It is important that the anticipator setpoint be correct. T oo high of a setting will result in longer heat cycles and a greater temperature swing in the conditioned space. Reducing the value below the correct setpoint will give shorter “ON” cycles and may result in the lowering of the temperature within the conditi[...]
-
Page 14
035-12046-003-A-0204 14 Unitary Products Group SECURE OWNER'S APPROV AL : When the system is functioning properly , secure the owner's approval. Show him the location of all disconnect switches and the thermostat. T each him how to start and stop the unit and how to adjust tem - perature settings within the limitations of the system. MAIN[...]
-
Page 15
035-12046-003-A-0204 Unitary Products Group 15[...]
-
Page 16
Unitary Products Group 5005 York Drive, Norman, Oklahoma 73069 Subject to change without notice. Printed in U.S.A 035-12046-003-A-0204 Copyright © 2004 by Unitary Products Group. All Rights Reserved. Supersedes: 035-12046-002-A-0302[...]