Go to page of
Similar user manuals
-
Air Conditioner
York E*FH018
24 pages 0.5 mb -
Air Conditioner
York DH 210
44 pages 1.68 mb -
Air Conditioner
York H*RC036S
24 pages 0.29 mb -
Air Conditioner
York YCJD18 THRU 60
18 pages 0.56 mb -
Air Conditioner
York ECO2 YPAL 050
168 pages 7.96 mb -
Air Conditioner
York MMC 25S24U15
10 pages 2.68 mb -
Air Conditioner
York ECO HFC-410A
44 pages 0.73 mb -
Air Conditioner
York YOCC-YOHC 12-60
8 pages 1.05 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of York FRCS024, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York FRCS024 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of York FRCS024. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of York FRCS024 should contain:
- informations concerning technical data of York FRCS024
- name of the manufacturer and a year of construction of the York FRCS024 item
- rules of operation, control and maintenance of the York FRCS024 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York FRCS024 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York FRCS024, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York FRCS024.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the York FRCS024 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
036-21004-002 Re v . B (0602) FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE SPLIT -SYSTEM AIR CONDITIONERS 14 SEER MODELS: FRCS024 THRU 060 (2 THRU 5 NOMINAL TONS) Due to continuo us product impr ovement, specifica tions are subjec t to change without notice . Visit us on the web at www .yo rk.com for the most up-to-date techni[...]
-
Page 2
036-21004-002 Rev. B (0602 ) 2 Unitary Products Group Physical and Electr ical Dat a MODEL FRCS0241BD FRCS0301BD FRCS0361CD FRCS0421CE FRCS0481CE F RCS0601BF Unit Supply V oltage 208 / 230 - 1 – 60 Normal V oltage Range 1 187 to 252 Minimum Circuit Ampacity 12.1 14.9 18.1 17.8 20.6 31.8 Max Overcurrent Device Amps 2 20 20 25 30 35 50 Compressor T[...]
-
Page 3
036-21004-002 Rev. B (0602) Unitary Products Group 3 - = Not applicable COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRIC 2 HEA T KW W RA TED CFM NET MBH SEER W/O TXV SEER + TXV 3 EER TOT AL SENS. 1 PH 14 SEER AC WITH N-AH / G2FD FRCS0241BD N1AHB0806 2,5,8,10 17 G2FD036S17 800 25.2 18.1 - 14.00 1[...]
-
Page 4
036-21004-002 Rev. B (0602 ) 4 Unitary Products Group COOLING CAP ACITY - Upflow , Downflow , & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER + TXV W/O TDR SEER + TXV 1 + TDR* EER TOT AL S EN S. FRCS0241BD 700 900 14 G1F A036S1 4 800 25.0 18.0 13.85 - 12.30 17,21 G1F A036S[...]
-
Page 5
036-21004-002 Rev. B (0602) Unitary Products Group 5 * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. FRCS0601BF 1650 2150 21,24 G1F A060S21,24 1900 53.5 37.1 - 13.25 12.00 24 G2FD060S24 1 900 53.5 37.1 - 13.25 12.00 24 G2FD061H24 2050 54.5 39.1 - 13.[...]
-
Page 6
036-21004-002 Rev. B (0602 ) 6 Unitary Products Group 1. For condensing unit only . Does not include ef fe ct of evaporator motor power or heat. 2. Performance based on 1 5° superheat and 1 5° sub-cooling at condensing unit. a. Increa se capacit y 1% for e ach 2° in crease in sub-cool ing. b. Decrease capacity 1% for eac h 2° decrease in sub-co[...]
-
Page 7
036-21004-002 Rev. B (0602) Unitary Products Group 7 TYPICAL INST ALLA TION TYPICAL FIELD WIRING MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE 60” OVERHEAD CLEARANCE 10” CLEARANCE COIL AREA WEA THERPROOF DISCONNECT SWITCH THERMOST A T TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING TO INDOOR COIL SEAL OPENING[...]
-
Page 8
036-21004-002 Rev. B (0602 ) 8 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0241BD INDOOR COIL MODEL NO. F2RP/F2FP036 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1 100 1250 1350 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6[...]
-
Page 9
036-21004-002 Rev. B (0602) Unitary Products Group 9 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0301BD INDOOR COIL MODEL NO. G1F A04 8S21, 24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 800 1000 1200 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 [...]
-
Page 10
036-21004-002 Rev. B (0602 ) 10 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0361 CD INDOOR COIL MODEL NO. G1F A04 8S21, 24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1000 1200 1400 ID DB 85 80 70 85 80 70 85 80 70 ID WB 72 67 57 72 67 57 72[...]
-
Page 11
036-21004-002 Rev. B (0602) Unitary Products Group 11 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0421CE INDOOR COIL MODEL NO. G1F A060S21,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1300 1450 1550 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 [...]
-
Page 12
036-21004-002 Rev. B (0602 ) 12 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0481 CE INDOOR COIL MODEL NO. G1F A06 0S21,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1400 1600 1800 ID DB 85 80 70 85 80 70 85 80 70 ID WB 72 67 57 72 67 57 72 [...]
-
Page 13
036-21004-002 Rev. B (0602) Unitary Products Group 13 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0601BF INDOOR COIL MODEL NO. G1F A06 0S21, 24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1600 1800 2000 ID DB 85 80 70 85 80 70 85 80 70 ID WB 72 67 57 72 67 57 72 6[...]
-
Page 14
036-21004-002 Rev. B (0602 ) 14 Unitary Products Group MA TCHING INDOOR COMPONEN TS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) * Available with factory installed horizontal drain p an. ADD-ON COILS - FOR FURNACE APPLICA TIONS G1NA UNCASED UPFLOW G1F A FULL CASED UPFLOW AIR HANDLERS - FOR NO[...]
-
Page 15
036-21004-002 Rev. B (0602) Unitary Products Group 15 NOTES[...]
-
Page 16
Subject to change without notice. Printed in U.S.A. 036-21004-002 Rev. B (0602) Copyright © by York International Corp. 2002. All rights reserved. Supersedes: 036-2100 4-002 Rev. A (0502) Unitary 5005 Norman Product Y ork OK Group Drive 73069[...]