Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Zephyr AK9800, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Zephyr AK9800 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Zephyr AK9800. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Zephyr AK9800 should contain:
- informations concerning technical data of Zephyr AK9800
- name of the manufacturer and a year of construction of the Zephyr AK9800 item
- rules of operation, control and maintenance of the Zephyr AK9800 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Zephyr AK9800 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Zephyr AK9800, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Zephyr service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Zephyr AK9800.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Zephyr AK9800 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
2EADALL)NSTRUCTIONSBEFORE)NSTALLINGANDOPERATINGTHISAPPLIANCE -/$%, AK2000,AK6000,AK9800 )MPORTANT3AFETY.OTICE 5SE#AREAND)NSTALLATION'UIDE : $51,1* 725('8&(7+(5,6.2)),5(25(/(&75,&6+2&.'2127 86(7+[...]
-
Page 2
)MPORTANT3AFETY.OTICE 2EADANDSAVETHESEINSTRUCTIONS G 8VHDQH[WLQJXLVKHU21/ <LI < RXNQRZRXKDYHD&ODVV$%&H[WLQJXLVKHU DQGRXDOUHDGNQRZKRZ WRRSHUDWHLW 7KHILUHLVVPDOODQGFR[...]
-
Page 3
PRODUCT OVERVIEW WHIRLWIND SERIES HURRICANE SERIES CYCLONE SERIES 1 Model number: AK2000, 2036 QuattroVent Air Curtain Dual “Thrust-Fore" Self Clean Blowers Digital Touch Pad Controls Clock, Timer, 3 stage Delay Shutoff. Model number: AK9 8 00 Dual Self Clean Blowers Independent Rocker Controls w/ High, Low speed Slim Line Design Overview 1.[...]
-
Page 4
CONTROLS HURRICANE SERIES 2 Controls Overview 1. Set Time 2. Digital Display 3. Set Hours 4. Set Minutes 5. Set Timed Delay Shut Off 6. Light On-Off 7. Left Blower: On-High-Low-Off 8. Right Blower: On-High-Low-Off 9. Operations: On-Off 10. Right Blower Low Speed Indicator 11. Right Blower High Speed Indicator 12. Left Blower Low Speed Indicator 13.[...]
-
Page 5
Blower Controls You can simultaneously turn On the light and both blowers on Hi speed by simply pressing "On/Off" once. During this time, you can select blowers and speed as indicated by pressing the "Fan-L" and "Fan-R" button. Note: The third press on the "Fan-L" and "Fan-R" button will turn blower[...]
-
Page 6
CONTROLS 4 Setting Timer (Alarm) Press " hr " and " min " button to set desired timer countdown. Once timer is set, countdown will start in 7 seconds as delay indicator light flashes. When countdown reaches 0, 10 short beeps will sound. To cancel timer after setting, press "On/Of f" button to terminate all operations a[...]
-
Page 7
MAINTENANCE 5 Self Clean Feature All Zephyr Range Hoods are filter-less and are designed with a self clean feature. The centrifugal blower system automatically liquefies grease accumulated in its internal housing. All systems are equipped with dishwasher safe grease containers for its self clean function. Grease and residue from cooking are often a[...]
-
Page 8
Hurricane Series: Remove light shield by turning counter- clockwise. Clean in dishwasher under normal wash cycle. Whirlwind Series: Remove light shield by unscrewing Philips screw. Clean in dishwasher under normal wash cycle. Cleaning Tip: Fill residue containers ¼ full with water before cleaning or during regular use. This will help to prevent gr[...]
-
Page 9
MAINTENANCE 7 QuattroVent Channels The QuattroVent Air-Curtain channels are adjoined to its two main blowers and share the same internal housing. No further cleaning is required after the self clean is completed. Clean residue around the channels surface with ‘409’ and a cotton cloth regularly. Replacing Lights All light bulbs included are 40W [...]
-
Page 10
INST ALLA TION 8 REQUIREMENTS ACCESSORIES WARNING Installation of this product is intended for qualified installers, service technicians, or persons with similar qualified background. DO NOT attempt to install this appliance yourself. Injury could result form installing the unit due to lack of appropriate electrical knowledge and technical backgrou[...]
-
Page 11
INST ALLA TION 9 MIN. 18” MAX 30” net width DUCT OPENING CLEARANCES Front Rear Front Rear Wall Minimum clearance above range should be no less than 18“ from the range surface to the range hood’s base. Maximum height are recommended not to exceed 30” for maximum efficiency. Net width on all models are call out width less 1/4”. Note: Refe[...]
-
Page 12
INST ALLA TION 10 STEP 1 STEP 3 STEP 5 STEP 2 STEP 4 STEP 6 (also refer notes on pg. 16) 1. Remove all contents from box 2. Unscrew and remove bottom grease splash shield 1. Locate electrical connection box knock out from left rear of hood and pry open with screwdriver 1. Cut out cabinet base opening if necessary. Refer cut out dimensions previous [...]
-
Page 13
INST ALLA TION 11 STEP 7 STEP 9 (also refer notes on pg. 16) STEP 11 STEP 8 STEP 10 STEP 12 (also refer notes pg. 16) 1. Lift hood to bottom of cabinet 1. Support hood to place, fasten both rear with screws and washers provided. 1. Fasten front of hood. Level all sides and adjust accordingly.** 1. Drill out cabinet base through electrical box with [...]
-
Page 14
INST ALLA TION 12 STEP 13 STEP 15 STEP 17 STEP 14 STEP 16 STEP 18 1. On Cyclone & Whirlwind models, be sure to pull both grease tubes over its opening. 1. Turn on electrical supply or plug into receptacles. 1. Reinstall electrical box cover. 1. Next, fasten the 3 front screws and begin tightening all screws from rear to front. 1. Connect duct t[...]
-
Page 15
INST ALLA TION 13 CONVERTIBLE OPTIONS 3-1/4 x 10“ Vertical Discharge 1. Remove pre-mounted 6“ transition adaptor on duct opening. Leave attached gasket in its original place. 3. Mount the 3-1/4 x 10“ starting collar on top of transition piece with remaining screws. 2. Place rectangular transition adaptor as shown over gasket and by first inst[...]
-
Page 16
INST ALLA TION 14 3-1/4 x 10“ Rear Discharge 4. At rear of range hood, remove all screws on pre- mounted rear rectangular cap and remove cap with gasket. 6. Remove 2 arch blocks through top opening. Option 1: (for recessed cabinet base) Re-install originally pre-mounted round transition piece at opening with gasket. 7. Mount Starting Collar (prov[...]
-
Page 17
INST ALLA TION 15 3-1/4 x 10“ Rear Discharge Option 2: (for flush cabinet base) Mount rectangular transition piece at opening with gasket as shown. Mount rectangular cap (previously removed) on top of transition adaptor.[...]
-
Page 18
INST ALLA TION 16 INSTALLA TION NOTES Step 6: A damper (not included) should be installed to prevent back-draft where needed. A damper might also be required local codes in order to qualify for building inspections. You can purchase dampers from most hardware stores, or call our service line to order. When a damper is not installed, a starting coll[...]
-
Page 19
TROUBLE SHOOTING 17 1. Upon completion of installation, nothing works. 2. Light is on but blowers are not turning at all or seems to be scraping on something. 3. When blowers are on, something seems to be loose and spinning around inside. 4. Vibration when blowers are on 5. Blowers noise 6. Light is not working 7. No grease is collected in the resi[...]
-
Page 20
TROUBLE SHOOTING 18 11. Cooking fumes and smoke dissipates before it reaches the blower. Use a damper type sidewall cap. Reduce the number of elbows and length of duct work. Check if all joints are properly connected, sealed and taped. Check if unit is installed at the recommended height (page 9). The range hood should also be able to cover the ent[...]
-
Page 21
www.zephyronline.com Warranty One Y ear Service Repair W arranty: F or one year from date of original purchase, we will provide free of c harge, service lab or to repair any failed parts or components due to manufacturing defects. T en Y ears Parts W arranty: F or ten years from date of original purchase, we will provide free of c harge, nonconsuma[...]