Go to page of
Similar user manuals
-
Ventilation Hood
Zephyr ZGE-E36AS
49 pages 3.1 mb -
Ventilation Hood
Zephyr AED - M90ASX
27 pages 1.81 mb -
Ventilation Hood
Zephyr ATI-M90ABX
22 pages 2.06 mb -
Ventilation Hood
Zephyr AK11365
23 pages 0.9 mb -
Ventilation Hood
Zephyr ATI-M90ASX
22 pages 2.06 mb -
Ventilation Hood
Zephyr ZRM-E36AS
19 pages 0.41 mb -
Ventilation Hood
Zephyr EGL-E36AS
21 pages 0.44 mb -
Ventilation Hood
Zephyr AK7500ASX
22 pages 0.38 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Zephyr ALL-M90ABX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Zephyr ALL-M90ABX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Zephyr ALL-M90ABX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Zephyr ALL-M90ABX should contain:
- informations concerning technical data of Zephyr ALL-M90ABX
- name of the manufacturer and a year of construction of the Zephyr ALL-M90ABX item
- rules of operation, control and maintenance of the Zephyr ALL-M90ABX item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Zephyr ALL-M90ABX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Zephyr ALL-M90ABX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Zephyr service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Zephyr ALL-M90ABX.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Zephyr ALL-M90ABX item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
ww w .zeph yronline .com Duo Is. ADL-M90ASX ADL-E42ASX Lay ers Is. ALL-M90ABX ALL-M90A WX ALL-E42A WX ALL-E42ABX RANGE HOOD - Installation instructions[...]
-
Page 2
ww w .zeph yronline .com HO T TE PER CUISINE - Notice d’utilisation ...P ag. 25 CAMP ANA EXTRACT OR A - Manual de utilización ...P ag. 48 CAPP A ASPIRANTE - istruzioni per l’uso ...P ag. 73 - 2 -[...]
-
Page 3
C onten ts SAFETY INSTRUC TIONS .................................................................................................. pag . 4 LIST OF MA TERIALS ........................................................................................................... pag . 7 DUCTING C AL CULA TION SHEETS ..............................................[...]
-
Page 4
ww w .zeph yronline .com IMPORT ANT SAFETY INSTRUC TIONS FOR RESIDENTIAL USE ONL Y READ AND SA VE THESE INSTRUC TIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORT ANT : Save these Instructions for the Local Electrical Inspectors use. INST ALLER : Please leave these Instructions with this unit for the owner . OWNER : Please retain these[...]
-
Page 5
settings. B. Always turn hood ON when c ook ing at high heat or when ambeing foods ( i.e. Cr epes Suzette , Cherries Jubilee, P eppercorn Beef F lambè ). C. Clean ventilating fans fr equently . Grease should not be allow ed to accumulate on fan or lter . D. Use proper pan siz e. Alwa ys use cookware appropriat e for the siz e of the sur fa[...]
-
Page 6
ww w .zeph yronline .com through the ue (chimney) of fuel burning equipment to pr event back drafting. F ollow the heating equipment manufacturer ’ s guideline and safety standards such as those published by the National F ire Pr otec tion Association (NFP A), and the American Society for Heating, Refrigeration and Air C onditioning Engineers[...]
-
Page 7
List of Materials Decorative Mesh F ilters Cont rol Blower Housing Light Bulbs Range Hood Body Duct Covers Suppor t F rame Assembly Light P anel TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 28 C 1/4" x 2-3/4" 4 Models: ADL-M90ASX / ADL -E42ASX - 7 -[...]
-
Page 8
ww w .zeph yronline .com List of Materials TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 28 C 1/4" x 2-3/4" 4 Duct Covers Suppor t F rame Assembly Blower Housing Range Hood Body Glass Decorative Mesh F ilters Light Bulbs Cont rol Models: ALL-M90ABX / ALL -M90A WX / ALL -E42A WX / ALL -E42ABX - 8 -[...]
-
Page 9
Duc ting Calcula tion Sheet Maximum Duct Length: F or satisfac tory air mov ement, the total duct length should not exceed 100 equivalent f eet. - 9 -[...]
-
Page 10
ww w .zeph yronline .com 35-3/8" or 42" W ood T rim Dimensions 1-5/8" Thick ness 23-5/8" 13" 11-1/4" Hood Speci cations front of hood side of hood top of hood Models: ADL-M90ASX / ADL -E42ASX - 10 -[...]
-
Page 11
Hood Speci cations front of hood side of hood top of hood Models: ALL-M90ABX / ALL -M90A WX / ALL -E42A WX / ALL -E42ABX - 11 -[...]
-
Page 12
ww w .zeph yronline .com Installation - In ternal Blow er The follo wing instruc tions are for installing the internal blo wer . CA UTION: T o reduce the risk of re and electric shock, install this range- hood only with internal blow er models MT -020 provided with the kit cod CBI-600A. F or external and in-line blower prepar ation please turn [...]
-
Page 13
Installation - In ternal Blow er 6. Attach the 6 pin male molex connector from blower wir e to the 6 pin female molex con- nector located inside the blower housing . See Fi g. 6 7. Install the motor and bracket, inside the motor housing, c ompleting the installation using the other screws (6 type B )that hav e been sup - plied. ( T ot. 13 t ype B).[...]
-
Page 14
ww w .zeph yronline .com Installation - External & In-Line Blow er Pr epar ation The follo wing instruc tions are for pr eparing the hood for use with an e x- ternal or in-line blow ers models CBE-1000 or PBN-1000A. CA UTION: T o reduce the risk of re and electric shock, install this rangehood only with remote blow ers rated maximum 6.2 A. [...]
-
Page 15
Installation - External & In-Line Blow er Pr epar ation Note1 : A cable lock (not included) may be re- quired by local c odes. Please r eview local co- des for mor e information. 6. Reinstall the cov er on the motor housing by follo wing the instructions from step 2 in re- verse or der . 7. Attach 6 pin male molex connectors to 6 pin female mol[...]
-
Page 16
ww w .zeph yronline .com W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls , crawl spaces, c eiling, attics or garages . All exhaust must be ducted to the outside, unless using the r ecirculating op- tion. Use single wall rigid Metal ductwork only . F asten all connections with sheet metal screws and tape all j[...]
-
Page 17
MOUNTING HEIGHTS The range hood must be installed at a minimum height of 24 inches (61 cm) from the cooking sur face. If a connecting duc t work c omposed of two par ts is used, the upper part must be placed outside the low er par t. Do not connect the range hood duc t to the same duct used to exhaust hot air or fumes from another appliance . Befor[...]
-
Page 18
ww w .zeph yronline .com into the attic to connect after the hood is installed. F ig.11 3. Place assembled support frames on top of hood and secure it t o the hood body using 8 type B screws. F ig.12 4. Place duct covers o ver assembled suppor t frame until they rest on the hood body . F ig.13 Note! If you ordered a w ood trim piece or re - circula[...]
-
Page 19
5. P osition hole template on the ceiling paying at- tention that the arro w is positioned on the same side as the range hood controls . - Make 4, holes in the ceiling and drive in (3 type C) screws without c ompletely tightening them. P ay attention not to insert the screw into the hole marked with an X on the hole template F ig.14 6. Lift the hoo[...]
-
Page 20
ww w .zeph yronline .com Installation - P o wer Supply C onnec tion GENERAL • Carefully r ead the following impor tant information r egarding installation safety and maintenance . Keep this information book let accessible f or fur ther consultations. POWER SUPPL Y C ONNEC TION F or connec tion to the po wer supply ref er to the f ollowing: 1. T e[...]
-
Page 21
Installation - P o wer Supply C onnec tion - Connect the electrical conduit to the F ield Wiring C ompar tment using listed onduit ttings. - Carry out the power supplly connection in accor dance with the national electric code, ANSI/NFP A 70-1999. 5. Replace the lid by f ollowing the instruc tions from st ep 3 in reverse or der , ensu- ring tha[...]
-
Page 22
ww w .zeph yronline .com Maintencanc e MAINTENANCE • It is recommended to operate the appliance prior t o cooking. It is recommended to leav e the appliance in operation f or 5 minutes after cooking is completed in order to c ompletely eliminate cooking vapors and odors. The pr oper func tion of the range hood is conditioned by the r egularity of[...]
-
Page 23
List of P ar ts and A c cessories DESCRIPTION HOOD P ART# REPLA CEMENT P ART S Light Bulb G4, 20W (each) ADL Z0B0013 Light Bulb GU4, 20W (each) ALL Z0B0030 OPTIONAL A CCESSORIES Recirculating Kit ADL, ALL ZRC-00LL Replacement Char coal F ilt ers ADL, ALL Z0F-00AC Duct Cover Extension, Short (9” ceiling) ADL, ALL Z1C-00LL Duct Cover Extension, L o[...]
-
Page 24
ww w .zeph yronline .com - 24 -[...]
-
Page 25
3LIK0500[...]