Go to page of
Similar user manuals
-
Ventilation Hood
Zephyr ZRM-E42BS290
40 pages 3.87 mb -
Ventilation Hood
Zephyr ADU - M90ASX
2 pages 1.01 mb -
Ventilation Hood
Zephyr ASU - M90ASX
27 pages 1.81 mb -
Ventilation Hood
Zephyr APN-M90AWX
20 pages 3.26 mb -
Ventilation Hood
Zephyr EOT-E42ASX
22 pages 0.66 mb -
Ventilation Hood
Zephyr ZMI-M90S
15 pages 0.58 mb -
Ventilation Hood
Zephyr AK11005
23 pages 0.9 mb -
Ventilation Hood
Zephyr AK8800AS
17 pages 0.63 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Zephyr EBO-E42ASX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Zephyr EBO-E42ASX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Zephyr EBO-E42ASX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Zephyr EBO-E42ASX should contain:
- informations concerning technical data of Zephyr EBO-E42ASX
- name of the manufacturer and a year of construction of the Zephyr EBO-E42ASX item
- rules of operation, control and maintenance of the Zephyr EBO-E42ASX item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Zephyr EBO-E42ASX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Zephyr EBO-E42ASX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Zephyr service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Zephyr EBO-E42ASX.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Zephyr EBO-E42ASX item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
JAN06.0101[...]
-
Page 2
2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST AL LA TION MUST COMPL Y WITH ALL LOCAL CODES. IMP ORT ANT : Save these Instructions for the Local Electrical Inspector s use. INS T ALLER: Please leave these Instructions with this unit for the owner . OWNER: Please ret ain these instructions for future reference. Safety W arning: T urn [...]
-
Page 3
3 www .zephyronline.com T able of Content s Important safet y Notice ..................................................................... 4 Electrical & Installa tion requir ements ............................................. 5 Electrical requirements .............................................................. 5 Before installing the hood [...]
-
Page 4
4 Import ant safety Notice CAUTION: FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR VA P O R S . W ARNING T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, O R INJURY T O PERSONS, OBSER VE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer . If you have questions, contact the m[...]
-
Page 5
5 www .zephyronline.com Electrical & Inst allation requirement s ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customers responsibility: T o co nt act a qualified electrical inst all er . T o assure that the electrical installation is adequate and in conformance with National Electrical Code[...]
-
Page 6
6 List of Materials PARTS SUPPLIED: Blower unit housing Hood canopy Met al filter x 1 Halogen light bulb x 2 Duct covers Remote Control Hardware Packet: Allen spanner x 1 Lower support bracket Te m p l a t e Use, Care and Inst allation guide 2,9x6,5 screws x 4 (to fix duct cover) 6x20 screws x2 + bushings (to fix vapour [...]
-
Page 7
7 www .zephyronline.com Dimensions and clearances 19" 1 1/16 5/8" 2"min 7" 1/2* Side Cabinet Side Cabinet 35" 7/16 min. cabinets opening wid ths 24" to 32" bottom of canopy to cooking surface ceiling CenterLine 14" 6/8 26" 12" 12" Ducting and conduit area passage(Duct bends are not considered) [...]
-
Page 8
8 Inst allation Instructions Closely follow the instructions set out in this manual. All responsibility , for any eventu al inc onve nien ces, damage s or fires caused by not comp lyin g with the instru ctio ns in this manual, is declined. VENTING METHODS The hood is equipped with a transition B for discharge of fumes to the outside ( Ducting versi[...]
-
Page 9
9 www .zephyronline.com Inst allation - Ductwork Calculation Sheet 3 1/4 x 10 Rect., straight 6 Round,, straight 7", 8 Round,, straight 3 1/4 x 10 Rect.90° elbow 3 1/4 x 10 Rect.45° elbow 3 1/4 x 10 Rect.90° flat elbow 3 1/4 x 10 Rect. wall cap with damper 3 1/4 x 10 Rect.to 6 round trans[...]
-
Page 10
10 Inst allation 1. If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier ac ce ss to re ar wa ll . O th er wi se pu t a th ic k, pr ot ec ti ve covering over countertop, cooktop or range to protect from damage or dirt. Select a flat surface for assembling the unit. Cover that surface with a protecti[...]
-
Page 11
11 www .zephyronline.com 15. Install the vapour screen with 2 screws and bushes using the allen sp anner included. Glass Bush + Screw 16. Hang hood with the 2 mounting hooks. W ARNING Excessive Weight Hazard - Use two o r more people to move and install range hood. Failure to do so can result in back or other injury . 17. Level the appliance, using[...]
-
Page 12
12 19. Connect ducting to transition. Seal with duct tape. Do not use duct smaller than the transition. For Ductless - recirculating - installations only: provide and install a duct to connect hood transition to deflector (the deflector is available as an extra kit). 20. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off pow[...]
-
Page 13
13 www .zephyronline.com 24. Install duct cover with 4 screws. Note: Upper Duct Cover may be placed upside down to hide (or unhide) ventless slots. Lower duct cover Duct cover support bracket Duct cover support bracket Upper duct cover TOP VIEW 25. Check all light bulbs to make sure they are secure in their sockets. T urn power on in service panel.[...]
-
Page 14
14 Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp (position and nr . of lamp s m ay v ary ) 5 Hood canopy 6 Duct cover 7 Air outlet (used for Ductless version only) 1 6 7 5 4 4 2 3[...]
-
Page 15
15 www .zephyronline.com Description of the hood - Control Ball CONTROLS Use the high suction speed in cases of concentrated kitchen v apours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes appr oxima tely after terminating cooking. Des[...]
-
Page 16
16 Description of the hood - Remote Control USING THE REMOTE CONTROL This device complies with p art 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The [...]
-
Page 17
17 www .zephyronline.com Maintenance Prior to any maintenance operation ensure that the cooker hood is disconnected from the power supply . CLEANING The cooker hood should be cleaned regularly internally and externally . For cleaning use a cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the[...]
-
Page 18
18 T rouble Shooting Af ter inst allation, the unit doesnt work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Met al filter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable locking connector is not connecting p[...]
-
Page 19
19 www .zephyronline.com W arranty T O O BT AIN SERVICE UNDER W ARRANTY : or any Service Related Questions, please call: 1-888-880-8368 S taple your receipt here. Proof of the original purchase date is needed to obtain ser vic e under the warranty . T O O B T AIN SERVICE UNDER W ARRANTY : Y ou must present proof of original purchase date. Please ke[...]
-
Page 20
20 List of Part s and Accessories Part Description Part# Ductless Recirculating Kit charcoal replacement filter duct cover extension kit internal blower - 600 cfm in-line blower - 1 100 cfm EBI-600A EBN-1 100 A Z1C-00BO Z0F-C060 ZRC-00BO Part Description Pa r t# halogen bulb, 12V 20 W metal filter remote control (RF) remote control battery ..394 of[...]
-
Page 21
21 www .zephyronline.com[...]
-
Page 22
22[...]