Go to page of
Similar user manuals
-
Ventilation Hood
Zephyr Z1C-01TI
8 pages 0.81 mb -
Ventilation Hood
Zephyr ADL-M90ASX
2 pages 0.98 mb -
Ventilation Hood
Zephyr CTP-E 60SX
23 pages 0.63 mb -
Ventilation Hood
Zephyr ZTO-M795
17 pages 0.26 mb -
Ventilation Hood
Zephyr ZVE-E42AS
20 pages 0.75 mb -
Ventilation Hood
Zephyr ZRM-E42BS
40 pages 3.87 mb -
Ventilation Hood
Zephyr Z1C-00TI
8 pages 0.81 mb -
Ventilation Hood
Zephyr ZRM-E42BS290
40 pages 3.87 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Zephyr ZRM-E36AS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Zephyr ZRM-E36AS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Zephyr ZRM-E36AS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Zephyr ZRM-E36AS should contain:
- informations concerning technical data of Zephyr ZRM-E36AS
- name of the manufacturer and a year of construction of the Zephyr ZRM-E36AS item
- rules of operation, control and maintenance of the Zephyr ZRM-E36AS item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Zephyr ZRM-E36AS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Zephyr ZRM-E36AS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Zephyr service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Zephyr ZRM-E36AS.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Zephyr ZRM-E36AS item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: SEP07.0101 © Zephyr Corporation Roma Island ZRM-E36AS ZRM-E42AS[...]
-
Page 2
www .zephyronline.com[...]
-
Page 3
1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options .....................[...]
-
Page 4
Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man[...]
-
Page 5
Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION 7 RUHGXFHULVNRI¿UHDQGWRSURSHUOH[KDXVWDLURXWVLGH'RQRWYHQWH[KDXVWDLULQWRVSDFHVZLWKLQZDOOVFHLOLQJV attics, crawl spaces or garages. OPERA TION $OZDVOHDYHVDIHWJULOOHV[...]
-
Page 6
List of Materials 4 www .zephyronline.com MODEL: ZRM-E36AS, ZRM-E42AS 2 Top Duct Covers 1 Top Support Frame 2 Bottom Duct Covers 1 Bottom Support Frame 2 Thin Trim Pieces 2 Thick Trim Pieces 1 Hood 4 Halogen Light Bulbs (pre-installed) 2 Metal Filters ( 3 - ZRM-E42AS) 3 Wire Nuts 4 ø14 OD / ø6.5 ID W ashers 4 M5 Wing Nuts 4 M6*50 Wood Screws 10 M[...]
-
Page 7
5 Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 F t. x ( ) = Ft. 8” Round, straight 1 F t. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 F t. x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 F t. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 flat elb ow 24 F t. x ( ) = Ft. 3-1/ 4” x 10” Rect. wa[...]
-
Page 8
Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4 x 10” rectangular GXFWPXVWEHXVHGWRPDLQWDLQPD[LPXPDLUÀRZ HI¿FLHQF Always use rigid type metal ducts only . Flexible GXFWVFRXOGUHVWULFWDLUÀRZEXSWR Use calculation w[...]
-
Page 9
7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only . )DVWHQDOOFRQQHFWLRQVZLWKVKHHWPHWDOVFUHZVDQGWDSHDOOMRLQWVZ?[...]
-
Page 10
8 www .zephyronline.com Installation – +RRG6SHFL¿FDWLRQV 3/4” 7 1/8 ” 10 3/4 ” 7 7/8 ” 10 1/8 ” 12 3/8 ” 8 3/4 ” FRONT 36” or 42” 27” 12” 14” 4” T op Support Frame (ceiling bracket) T op of Hood (blower housing) Side of Hood Front of Hood C/L 4 1/2 ” 3” 1 5/8 ” electrical K/O 1 1/8 ” 1/4” ø5 7/8” 11 5/8 [...]
-
Page 11
9 $GGDQGVHFXUHZRRGEORFNLQJ minimum 2 x 4 RQWRFHLOLQJMRLVWV 2. Fasten top support frame to desired location on ceiling using 4 2” wood screws with washers. The wider section of the support bracket faces the front of the hood. 3. Determine height requirement and secure bottom support frame to top support f[...]
-
Page 12
10 www .zephyronline.com 7 8 10 9 11 Top Duct Covers Top Support Frame Bottom Duct Covers Bottom Support Frame Thin Trim Piece Thick Trim Piece $VVHPEOHWRSGXFWFRYHUV With louver holes RYHUVXSSRUWIUDPH8VH0VFUHZV 3 on each side WRVHFXUHGXFWFRYHUVWRHDFK[...]
-
Page 13
11 Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust IURPFRRNLQJDUHGUDZQDQG¿OWHUHGEDVHWRIRSWLRQDOFKDUFRDO¿OWHUV7KHDLULVWKHQSX[...]
-
Page 14
12 www .zephyronline.com Blower Off Lights On/Off Blower On/Speed Selection Blower Off Blower On/Speed Selection Lights On/Off The blower will be switched off by pressing: Switch blower on and select speeds 1 - 3 by pressing: Switch lights on and off by pressing: Controls[...]
-
Page 15
13 SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser . After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buf[...]
-
Page 16
14 www .zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. 5HPRYHEWXUQLQJEXOEFRXQWHUFORFNZLVH1RWH%XOEGRHVQRWXQVFUH[...]
-
Page 17
T roubleshooting 15 TROUBLESHOOTING PROCEDURES FOR ROMA Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power connection with the unit is[...]
-
Page 18
16 www .zephyronline.com DESCRIPTION P ART# Replacement Parts /LJKW%XOE05*8:HDFK =%6 0HWDO)LOWHUHDFK Optional Accessories Recirculating Kit, ZRM-E36AS ZRC-0150 Recirculating Kit, ZRM-E42AS ZRC-0151 5HSODFHPHQW&KDUFRDO)LOWHUHDFK?[...]
-
Page 19
1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be fre[...]