Ir para a página of
Manuais similares
-
Clothes Dryer
American Dryer Corp. ML-130 II
59 páginas 0.81 mb -
Clothes Dryer
American Dryer Corp. ML-96HS
38 páginas 0.3 mb -
Clothes Dryer
American Dryer Corp. AD-758
61 páginas 0.77 mb -
Clothes Dryer
American Dryer Corp. ML-310
85 páginas 2.37 mb -
Clothes Dryer
American Dryer Corp. ADG-215
24 páginas 0.18 mb -
Clothes Dryer
American Dryer Corp. AD-235D
52 páginas 0.74 mb -
Clothes Dryer
American Dryer Corp. AD-758DV
66 páginas 1.4 mb -
Clothes Dryer
American Dryer Corp. ML-78II
46 páginas 0.42 mb
Bom manual de uso
As regras impõem ao revendedor a obrigação de fornecer ao comprador o manual com o produto American Dryer Corp. ML-96D. A falta de manual ou informações incorretas fornecidas ao consumidor são a base de uma queixa por não conformidade do produto com o contrato. De acordo com a lei, pode anexar o manual em uma outra forma de que em papel, o que é frequentemente utilizado, anexando uma forma gráfica ou manual electrónicoAmerican Dryer Corp. ML-96D vídeos instrutivos para os usuários. A condição é uma forma legível e compreensível.
O que é a instrução?
A palavra vem do latim "Instructio" ou instruir. Portanto, no manual American Dryer Corp. ML-96D você pode encontrar uma descrição das fases do processo. O objetivo do manual é instruir, facilitar o arranque, a utilização do equipamento ou a execução de determinadas tarefas. O manual é uma coleção de informações sobre o objeto / serviço, um guia.
Infelizmente, pequenos usuários tomam o tempo para ler o manual American Dryer Corp. ML-96D, e um bom manual não só permite conhecer uma série de funcionalidades adicionais do dispositivo, mas evita a formação da maioria das falhas.
Então, o que deve conter o manual perfeito?
Primeiro, o manual American Dryer Corp. ML-96D deve conte:
- dados técnicos do dispositivo American Dryer Corp. ML-96D
- nome do fabricante e ano de fabricação do dispositivo American Dryer Corp. ML-96D
- instruções de utilização, regulação e manutenção do dispositivo American Dryer Corp. ML-96D
- sinais de segurança e certificados que comprovam a conformidade com as normas pertinentes
Por que você não ler manuais?
Normalmente, isso é devido à falta de tempo e à certeza quanto à funcionalidade específica do dispositivo adquirido. Infelizmente, a mesma ligação e o arranque American Dryer Corp. ML-96D não são suficientes. O manual contém uma série de orientações sobre funcionalidades específicas, a segurança, os métodos de manutenção (mesmo sobre produtos que devem ser usados), possíveis defeitos American Dryer Corp. ML-96D e formas de resolver problemas comuns durante o uso. No final, no manual podemos encontrar as coordenadas do serviço American Dryer Corp. na ausência da eficácia das soluções propostas. Atualmente, muito apreciados são manuais na forma de animações interessantes e vídeos de instrução que de uma forma melhor do que o o folheto falam ao usuário. Este tipo de manual é a chance que o usuário percorrer todo o vídeo instrutivo, sem ignorar especificações e descrições técnicas complicadas American Dryer Corp. ML-96D, como para a versão papel.
Por que ler manuais?
Primeiro de tudo, contem a resposta sobre a construção, as possibilidades do dispositivo American Dryer Corp. ML-96D, uso dos acessórios individuais e uma gama de informações para desfrutar plenamente todos os recursos e facilidades.
Após a compra bem sucedida de um equipamento / dispositivo, é bom ter um momento para se familiarizar com cada parte do manual American Dryer Corp. ML-96D. Atualmente, são cuidadosamente preparados e traduzidos para sejam não só compreensíveis para os usuários, mas para cumprir a sua função básica de informação
Índice do manual
-
Página 1
ADC Part No. 113125 For replacement parts, contact the reseller from which the dryer was purchased or American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 T elephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry .com www .amdry .com 020200RF/pb W ARNING: For your safety the information in this manual must be followe[...]
-
Página 2
Retain This Manual In A Safe Place For Futur e Refer ence American Dryer Corporation products embody advanced concepts in engineering, design, and safety . If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment. OBSER VE ALL SAFETY P[...]
-
Página 3
IMPOR T ANT YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPL Y and THE GAS SUPPL Y BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, or TESTING OF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) ST ANDARDS. CHILDREN SHOULD NOT BE ALLOWED TO PLA Y ON OR NEAR T[...]
-
Página 4
W ARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJUR Y or FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer . Dryers must not be installed or stored in an area w[...]
-
Página 5
Table of Contents SECTION I IMPOR T ANT INFORMA TION ............................................................................... 3 A. Receiving and Handling ............................................................................................................... 3 B . Safety Precautions ....................................................[...]
-
Página 6
SECTION VII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS ....................................................................................................... 3 4 SECTION VIII DA T A LABEL/LOCA TION INFORMA TION ...................................................... 3 6 SECTION IX BURNER and BASKET (TUMBLER)/LINT CHAMBER MANUAL RESET [...]
-
Página 7
3 SECTION I IMPORTANT INFORMATION A. RECEIVING and HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and packaging, and wooden skid should be visually inspected for shipping damage. If any damage what[...]
-
Página 8
4 B. SAFETY PRECAUTIONS WARNING : For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING : The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY or FIRE COULD RES[...]
-
Página 9
5 7. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust ductwork, and inside the dryer. The frequency of inspection and cleaning can best be determined from experience at each location. WARNING : The collection of lint in the burner area and exhaust ductwork can create a potential fire hazard. [...]
-
Página 10
6 SECTION II SPECIFICATIONS/COMPONENT IDENTIFICATION A. SPECIFICATIONS IMPORTANT: Dryer must be supplied with clean, dry, and regulated air pressure at 80 PSI ± 10 PSI (5.51 bars ± 0.68 bars). NOTE : ADC reserves the right to make changes in specifications at any time without notice or obligation. GAS MAXIMUM CAPACITY (DRY WEIGHT) 95 lbs. 43.1 kg[...]
-
Página 11
7 NOTE : ADC reserves the right to make changes in specifications at any time without notice or obligation. Specifications ML-96D[...]
-
Página 12
8 B. COMPONENT IDENTIFICA TION 1. Dryer Front View Illus. No. Description 1 Microprocessor Control/Keyboard (touch pad) Panel Assembly (controls) 2 Control (top access) Door Assembly 3 Main Door Assembly 4 Lint Panel Assembly 5 Lint Door 6 Wire Diagram (located behind control door) 7 Top Console (module) Assembly[...]
-
Página 13
9 Illus. No. Description 1 Electrical Service Connections 2 Top Console 3 Heating Unit 4 Relay/Wiring Box 5 Data Label and Installation Label 6 Air Connection 7 Exhaust Transition Piece 8 Optional Exhaust Damper Assembly - if damper option was purchased at time dryer order was placed; the damper must be installed at time of dryer installation. If d[...]
-
Página 14
10 SECTION III INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrica[...]
-
Página 15
11 B. UNPACKING/SETTING UP Remove protective shipping material (i.e., plastic wrap and optional shipping box) from dryer. IMPORTANT : Dryer must be transported and handled in an upright position at ALL times. The dryer can be moved to its final location while still attached to the skid or with the skid removed. To unskid the dryer, locate and remov[...]
-
Página 16
12 1. Leveling Dryer To level dryer, place 4-inch (10.16 cm) square metal shims (refer to the illustration on page 11 ) or other suitable material under the base pads. It is suggested that the dryer be tilted slightly to the rear. If more headroom is needed when moving dryer into position, the top console (module) may be removed. a. To remove top c[...]
-
Página 17
13 C. DR YER ENCLOSURE REQUIREMENTS Even though a 30-inch (76.2 cm) clearance is acceptable, it is recommended that the rear of the dryer be positioned approximately 36-inches (91.44 cm) from nearest obstruction (i.e. wall) for ease of installation, maintenance and service. Bulkheads and partitions should be made from noncombustible materials. The [...]
-
Página 18
14 D. FRESH AIR SUPPL Y When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected. Ignition pr[...]
-
Página 19
15 E. EXHAUST REQUIREMENTS 1. General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure which results in slow drying, increased use of energy, overheating of the dryer, and shutdown of the burner by the airflow (sail) switches, bu[...]
-
Página 20
16 2. Single Dryer Venting Where possible, it is suggested to provide a separate exhaust duct for each dryer. The exhaust duct should be laid out in such a way that the ductwork travels as directly as possible to the outdoors with as few turns as possible. It is suggested that the use of 90° turns in the ducting be avoided ; use 30° or 45° angle[...]
-
Página 21
17 IMPORTANT : For extended ductwork runs, the cross section area of the ductwork can only be increased to an extent. Maximum proportional ductwork runs cannot exceed 20 feet (6.1 meters) more than the original limitations of 20 feet (6.1 meters) with one (1) elbow for horizontal runs and three (3) elbows for vertical runs. When the ductwork approa[...]
-
Página 22
18 3. Multiple Dryer (common) Venting If it is not feasible to provide separate exhaust ducts for each dryer, ducts from individual dryers may be channeled into a "common main duct." The individual ducts should enter the bottom or side of the main duct at an angle not more than 45º in the direction of airflow and should be spaced at leas[...]
-
Página 23
19 a. Outside Ductwork Protection 1) To protect the outside end of horizontal ductwork from the weather, a 90º elbow bent downward should be installed where the exhaust exits the building. If the ductwork travels vertically up through the roof, it should be protected from the weather by using a 180º turn to point the opening downward. In either c[...]
-
Página 24
20 Each dryer should be connected to an independently protected branch circuit. The dryer must be connected with copper wire only. DO NOT use aluminum wire, which could cause a fire hazard. The copper conductor wire or cable must be of proper ampacity and insulation in accordance with electric codes for making ALL service connections. NOTE : The us[...]
-
Página 25
21 3. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian El[...]
-
Página 26
22 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requireme[...]
-
Página 27
23 2. Technical Gas Data a. Gas Specifications b. Gas Connections Inlet connection ----------- 1-inch N.P.T. Inlet supply size ----------- 1-inch N.P.T. (minimum) Heat input (per dryer) ---- 350,000 BTU /hr input - 88,200 kcal/hr 1) Natural Gas Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressur[...]
-
Página 28
24 3. Piping and Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done[...]
-
Página 29
25 Consistent gas pressure is essential at ALL gas connections. It is recommended that a 1-inch (2.54 cm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column (W.C.) pressur[...]
-
Página 30
26 6. Be sure ALL side and base panels are on the dryer. 7. Check ALL service doors to insure that they are closed and secure. 8. Be sure the lint drawer is securely in place. IMPORTANT : LINT DRAWER MUST BE CLOSED TO ACTIVATE SAFETY SWITCH OTHERWISE THE DRYER WILL NOT START. 9. Rotate the basket (tumbler or drum) by hand to be sure it moves freely[...]
-
Página 31
27 3) Once ignition is established, a gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column (W.C.) pressure is correct and consistent. NOTE : Water column pressure requirements (measured at the gas valve pressure tap): Natural Gas ..........................3.5 inches (8.7 mb) water column. Liq[...]
-
Página 32
28 NOTE : The dryer can be stopped at any time by opening main door or by pressing the "STOP" key. To restart the dryer, press the "START" key or preprogrammed cycle key (i.e., key "E"). NOTE : Selection (setting) changes can be made at any time during the drying cycle by pressing the "STOP/CLEAR" key twice. [...]
-
Página 33
29 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is required, contact the reseller from whom the ADC equipment was purchased. If the reseller cannot be contacted or is unknown, contact the ADC Service Department for a reseller in your [...]
-
Página 34
30 SECTION V WARRANTY INFORMATION A. RETURNING W ARRANTY CARD(S) 1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass. These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you, if you file a[...]
-
Página 35
31 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure (be specific). c. Date of dryer installation. d. Date of part failure. e. Specify whether the parts being returned is for a replacement, a credit, or a refund. NOTE : If a part is marked for[...]
-
Página 36
32 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent upon[...]
-
Página 37
33 2. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment. 3. Clean any lint accumulation in and around both the blower and drive motor casing openings. EVERY 6 MONTHS Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer's internal exhaust ducting. Drive and idle[...]
-
Página 38
34 SECTION VII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. For Models With Johnson Controls Direct Spark Ignition (DSI) Module (G760) Theory Of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (6-seconds), the flame sensor detects gas burner flame and signals the DSI module to [...]
-
Página 39
35 2. For Direct Spark Ignition (DSI) System Models Manufactured With ADC M odule Part No. 880815 a. Upon completing installation of the replacement DSI module, reestablish power to the dryer. b. Starting the drying cycle. c. The ignition DSI module’s light emitting diode (L.E.D.) indicator will light “red” for up to approximately 1.5-seconds[...]
-
Página 40
36 SECTION VIII DATA LABEL/LOCATION INFORMATION A. DATA LABEL Contact American Dryer Corporation When contacting American Dryer Corporation certain information is required to insure proper service/parts information from American Dryer Corporation . This information is on the data label located to the left side panel/wall area behind the control doo[...]
-
Página 41
37 THE DATA LABEL 1. MODEL NUMBER The model number is an ADC number, which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows ADC to gather information on your particular dryer. 3. MANUFACTURING CODE NUMBER The manufacturing code number is a number issued by ADC, which describes[...]
-
Página 42
38 SECTION IX BURNER and BASKET (TUMBLER)/ LINT CHAMBER MANUAL RESET HI-LIMIT INSTRUCTIONS (FOR PHASE 6 MODELS) This dryer was manufactured with a burner manual reset hi-limit and basket (tumbler)/lint chamber hi-limit thermostat, which is monitored by the Phase 6 computer. If either manual reset thermostat is open prior to start of the drying cycl[...]
-
Página 43
ADC 113125 1 - 02/16/00-10 2- 12/08/00-10 3* 03/09/01-25[...]